{"title":"4-羟基香豆素-高锰酸盐氧化还原反应动力学催化测定微量Co(II)","authors":"D. Sejmanović, R. Micić, R. Simonović","doi":"10.5937/UNIVTHO8-16036","DOIUrl":null,"url":null,"abstract":"Determination of Co(II) based on its catalytic effect on the reaction between 4-hydroxycoumarine and potassium permanganate, in the presence of acetate buffer was described. The method development includes optimization of the reagent concentration and temperature. Absorbance of potassium permanganate was measured at 525 nm. The calibration curve was linear in the range of 0.5 - 4 ng/cm 3 of Co(II). The relative standard deviation was in the interval 6.25-2.60 % of the concentration range of 0.6-3 ng/cm 3 Co(II), respectively. The interference effects of foreign ions were determined for the assessment of the selectivity of the method. The proposed method was found to have excellent sensitivity, relatively good selectivity and simplicity.","PeriodicalId":22896,"journal":{"name":"The University Thought - Publication in Natural Sciences","volume":"8 1","pages":"17-21"},"PeriodicalIF":0.0000,"publicationDate":"2018-03-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"KINETIC-CATALYTIC DETERMINATION OF ULTRAMICRO AMOUNTS OF Co(II) USING 4-HYDROXYCOUMARINE-PERMANGANATE REDOX REACTION\",\"authors\":\"D. Sejmanović, R. Micić, R. Simonović\",\"doi\":\"10.5937/UNIVTHO8-16036\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Determination of Co(II) based on its catalytic effect on the reaction between 4-hydroxycoumarine and potassium permanganate, in the presence of acetate buffer was described. The method development includes optimization of the reagent concentration and temperature. Absorbance of potassium permanganate was measured at 525 nm. The calibration curve was linear in the range of 0.5 - 4 ng/cm 3 of Co(II). The relative standard deviation was in the interval 6.25-2.60 % of the concentration range of 0.6-3 ng/cm 3 Co(II), respectively. The interference effects of foreign ions were determined for the assessment of the selectivity of the method. The proposed method was found to have excellent sensitivity, relatively good selectivity and simplicity.\",\"PeriodicalId\":22896,\"journal\":{\"name\":\"The University Thought - Publication in Natural Sciences\",\"volume\":\"8 1\",\"pages\":\"17-21\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-03-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The University Thought - Publication in Natural Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5937/UNIVTHO8-16036\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The University Thought - Publication in Natural Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5937/UNIVTHO8-16036","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
KINETIC-CATALYTIC DETERMINATION OF ULTRAMICRO AMOUNTS OF Co(II) USING 4-HYDROXYCOUMARINE-PERMANGANATE REDOX REACTION
Determination of Co(II) based on its catalytic effect on the reaction between 4-hydroxycoumarine and potassium permanganate, in the presence of acetate buffer was described. The method development includes optimization of the reagent concentration and temperature. Absorbance of potassium permanganate was measured at 525 nm. The calibration curve was linear in the range of 0.5 - 4 ng/cm 3 of Co(II). The relative standard deviation was in the interval 6.25-2.60 % of the concentration range of 0.6-3 ng/cm 3 Co(II), respectively. The interference effects of foreign ions were determined for the assessment of the selectivity of the method. The proposed method was found to have excellent sensitivity, relatively good selectivity and simplicity.