Jingrui Chu, Shi-kui Wang, Runlin Gan, Wenhang Wang, Baoren Li, Gang Yang
{"title":"三热电偶对高温气体流量测温误差的动态补偿","authors":"Jingrui Chu, Shi-kui Wang, Runlin Gan, Wenhang Wang, Baoren Li, Gang Yang","doi":"10.1177/01423312231194603","DOIUrl":null,"url":null,"abstract":"The gas flow temperature signal simulation system (ATSSS) plays a crucial role in the hardware-in-the-loop simulation of hypersonic aircraft. The accuracy of gas flow temperature measurements is of paramount importance for the ATSSS. This system comprises a high-temperature plasma heater, a gas flow mixing chamber, and thermocouples. The ATSSS exhibits specific characteristics such as high temperatures, rapid temperature changes, and fast flow rates. However, due to the large measurement time constant of high-temperature thermocouples, significant dynamic errors are introduced into the measurement results. To address this issue and enhance the dynamic measurement accuracy of gas flow temperature, this study establishes a thermocouple heat transfer model for the ATSSS. It also analyzes the mechanism behind the generation of dynamic errors in the ATSSS and proposes a three-thermocouple coupled temperature measurement dynamic compensation method (TTCTMDC). This method compensates for errors caused by thermal convection, thermal radiation, and thermal conduction under high-temperature conditions. Simulation results demonstrate that the proposed method can reduce errors by 50% to 80%. In addition, an experimental platform for the ATSSS is constructed, and the TTCTMDC method is employed to compensate for measurement errors. The results indicate that the dynamic measurement error can be reduced to 1/4 to 1/2 of the original value using the TTCTMDC method. This research lays a foundation for the successful development of the ATSSS and provides a novel approach to dynamically measuring high-temperature gas flow, thereby advancing scientific research in the field of measurement.","PeriodicalId":49426,"journal":{"name":"Transactions of the Institute of Measurement and Control","volume":" ","pages":""},"PeriodicalIF":1.7000,"publicationDate":"2023-09-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Dynamic compensation by coupled triple-thermocouples for temperature measurement error of high-temperature gas flow\",\"authors\":\"Jingrui Chu, Shi-kui Wang, Runlin Gan, Wenhang Wang, Baoren Li, Gang Yang\",\"doi\":\"10.1177/01423312231194603\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The gas flow temperature signal simulation system (ATSSS) plays a crucial role in the hardware-in-the-loop simulation of hypersonic aircraft. The accuracy of gas flow temperature measurements is of paramount importance for the ATSSS. This system comprises a high-temperature plasma heater, a gas flow mixing chamber, and thermocouples. The ATSSS exhibits specific characteristics such as high temperatures, rapid temperature changes, and fast flow rates. However, due to the large measurement time constant of high-temperature thermocouples, significant dynamic errors are introduced into the measurement results. To address this issue and enhance the dynamic measurement accuracy of gas flow temperature, this study establishes a thermocouple heat transfer model for the ATSSS. It also analyzes the mechanism behind the generation of dynamic errors in the ATSSS and proposes a three-thermocouple coupled temperature measurement dynamic compensation method (TTCTMDC). This method compensates for errors caused by thermal convection, thermal radiation, and thermal conduction under high-temperature conditions. Simulation results demonstrate that the proposed method can reduce errors by 50% to 80%. In addition, an experimental platform for the ATSSS is constructed, and the TTCTMDC method is employed to compensate for measurement errors. The results indicate that the dynamic measurement error can be reduced to 1/4 to 1/2 of the original value using the TTCTMDC method. This research lays a foundation for the successful development of the ATSSS and provides a novel approach to dynamically measuring high-temperature gas flow, thereby advancing scientific research in the field of measurement.\",\"PeriodicalId\":49426,\"journal\":{\"name\":\"Transactions of the Institute of Measurement and Control\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2023-09-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Transactions of the Institute of Measurement and Control\",\"FirstCategoryId\":\"94\",\"ListUrlMain\":\"https://doi.org/10.1177/01423312231194603\",\"RegionNum\":4,\"RegionCategory\":\"计算机科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"AUTOMATION & CONTROL SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Transactions of the Institute of Measurement and Control","FirstCategoryId":"94","ListUrlMain":"https://doi.org/10.1177/01423312231194603","RegionNum":4,"RegionCategory":"计算机科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"AUTOMATION & CONTROL SYSTEMS","Score":null,"Total":0}
Dynamic compensation by coupled triple-thermocouples for temperature measurement error of high-temperature gas flow
The gas flow temperature signal simulation system (ATSSS) plays a crucial role in the hardware-in-the-loop simulation of hypersonic aircraft. The accuracy of gas flow temperature measurements is of paramount importance for the ATSSS. This system comprises a high-temperature plasma heater, a gas flow mixing chamber, and thermocouples. The ATSSS exhibits specific characteristics such as high temperatures, rapid temperature changes, and fast flow rates. However, due to the large measurement time constant of high-temperature thermocouples, significant dynamic errors are introduced into the measurement results. To address this issue and enhance the dynamic measurement accuracy of gas flow temperature, this study establishes a thermocouple heat transfer model for the ATSSS. It also analyzes the mechanism behind the generation of dynamic errors in the ATSSS and proposes a three-thermocouple coupled temperature measurement dynamic compensation method (TTCTMDC). This method compensates for errors caused by thermal convection, thermal radiation, and thermal conduction under high-temperature conditions. Simulation results demonstrate that the proposed method can reduce errors by 50% to 80%. In addition, an experimental platform for the ATSSS is constructed, and the TTCTMDC method is employed to compensate for measurement errors. The results indicate that the dynamic measurement error can be reduced to 1/4 to 1/2 of the original value using the TTCTMDC method. This research lays a foundation for the successful development of the ATSSS and provides a novel approach to dynamically measuring high-temperature gas flow, thereby advancing scientific research in the field of measurement.
期刊介绍:
Transactions of the Institute of Measurement and Control is a fully peer-reviewed international journal. The journal covers all areas of applications in instrumentation and control. Its scope encompasses cutting-edge research and development, education and industrial applications.