Baska面罩与ProSeal喉面罩对机械通气全麻病例气道密封压力的影响:一项随机对照试验

IF 0.6 Q3 ANESTHESIOLOGY Egyptian Journal of Anaesthesia Pub Date : 2023-07-31 DOI:10.1080/11101849.2023.2240662
Shady Rady Abdalla, A. Mohamed, Marianne Magdy Roshdy, Maha Mohamed Ismail, Ashraf Mohamed Abdelreheem, W. M. Bahnas, M. Soliman
{"title":"Baska面罩与ProSeal喉面罩对机械通气全麻病例气道密封压力的影响:一项随机对照试验","authors":"Shady Rady Abdalla, A. Mohamed, Marianne Magdy Roshdy, Maha Mohamed Ismail, Ashraf Mohamed Abdelreheem, W. M. Bahnas, M. Soliman","doi":"10.1080/11101849.2023.2240662","DOIUrl":null,"url":null,"abstract":"ABSTRACT Background Supraglottic Airway Devices (SGAs) are designed to counteract the drawbacks of endotracheal intubation. They have proven to be easy to use, robust, versatile, and usable in many difficult situations. This work aims to investigate the use of the Baska Mask (BM) airway and ProSeal™ Laryngeal Mask Airway (PLMA) as SGAs for ventilation. Methods This randomized controlled trial was carried out on 74 cases aged 21–65 years old for elective surgery of a planned duration of up to 2 h during general anaesthesia with intermittent positive pressure ventilation. Cases were divided into two equal groups. Ventilation was done either by BM® Airway (group BM) or PLMA (group PLMA). Results BM had a shorter insertion time and lower leak fraction versus PLMA, while seal pressure elevated significantly with BM versus PLMA (P < 0.001). PLMA had significantly more cases than the BM mask group complaining of a sore throat at 2 h (P = 0.042). Complication after gastric tube insertion was parallel between both groups. Conclusions BM can be used successfully during anesthesia as it displays a shorter insertion time, lower leak fraction, higher seal pressure, and lower incidence of sore throat and gastric tube insertion complications than PLMA.","PeriodicalId":11437,"journal":{"name":"Egyptian Journal of Anaesthesia","volume":" ","pages":""},"PeriodicalIF":0.6000,"publicationDate":"2023-07-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Baska mask vs ProSeal Laryngeal mask on airway seal pressure in cases undergoing general anesthesia by mechanical ventilation: A randomized controlled trial\",\"authors\":\"Shady Rady Abdalla, A. Mohamed, Marianne Magdy Roshdy, Maha Mohamed Ismail, Ashraf Mohamed Abdelreheem, W. M. Bahnas, M. Soliman\",\"doi\":\"10.1080/11101849.2023.2240662\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"ABSTRACT Background Supraglottic Airway Devices (SGAs) are designed to counteract the drawbacks of endotracheal intubation. They have proven to be easy to use, robust, versatile, and usable in many difficult situations. This work aims to investigate the use of the Baska Mask (BM) airway and ProSeal™ Laryngeal Mask Airway (PLMA) as SGAs for ventilation. Methods This randomized controlled trial was carried out on 74 cases aged 21–65 years old for elective surgery of a planned duration of up to 2 h during general anaesthesia with intermittent positive pressure ventilation. Cases were divided into two equal groups. Ventilation was done either by BM® Airway (group BM) or PLMA (group PLMA). Results BM had a shorter insertion time and lower leak fraction versus PLMA, while seal pressure elevated significantly with BM versus PLMA (P < 0.001). PLMA had significantly more cases than the BM mask group complaining of a sore throat at 2 h (P = 0.042). Complication after gastric tube insertion was parallel between both groups. Conclusions BM can be used successfully during anesthesia as it displays a shorter insertion time, lower leak fraction, higher seal pressure, and lower incidence of sore throat and gastric tube insertion complications than PLMA.\",\"PeriodicalId\":11437,\"journal\":{\"name\":\"Egyptian Journal of Anaesthesia\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.6000,\"publicationDate\":\"2023-07-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Egyptian Journal of Anaesthesia\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/11101849.2023.2240662\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ANESTHESIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Egyptian Journal of Anaesthesia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/11101849.2023.2240662","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ANESTHESIOLOGY","Score":null,"Total":0}
引用次数: 0
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Baska mask vs ProSeal Laryngeal mask on airway seal pressure in cases undergoing general anesthesia by mechanical ventilation: A randomized controlled trial
ABSTRACT Background Supraglottic Airway Devices (SGAs) are designed to counteract the drawbacks of endotracheal intubation. They have proven to be easy to use, robust, versatile, and usable in many difficult situations. This work aims to investigate the use of the Baska Mask (BM) airway and ProSeal™ Laryngeal Mask Airway (PLMA) as SGAs for ventilation. Methods This randomized controlled trial was carried out on 74 cases aged 21–65 years old for elective surgery of a planned duration of up to 2 h during general anaesthesia with intermittent positive pressure ventilation. Cases were divided into two equal groups. Ventilation was done either by BM® Airway (group BM) or PLMA (group PLMA). Results BM had a shorter insertion time and lower leak fraction versus PLMA, while seal pressure elevated significantly with BM versus PLMA (P < 0.001). PLMA had significantly more cases than the BM mask group complaining of a sore throat at 2 h (P = 0.042). Complication after gastric tube insertion was parallel between both groups. Conclusions BM can be used successfully during anesthesia as it displays a shorter insertion time, lower leak fraction, higher seal pressure, and lower incidence of sore throat and gastric tube insertion complications than PLMA.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Egyptian Journal of Anaesthesia
Egyptian Journal of Anaesthesia Medicine-Anesthesiology and Pain Medicine
CiteScore
0.90
自引率
0.00%
发文量
78
期刊最新文献
Intrathecal levo-bupivacaine versus hyperbaric bupivacaine for inguinal hernia repairs in ex-preterm infants: A double blinded randomized prospective study Comparison of two different methods as reliable predictors of successful caudal block in children Effect of sevoflurane versus propofol on early cognitive functions in elderly patients after lumbar disc surgery Muscle wasting assessed by ultrasound versus scoring systems as early predictor of outcomes of intensive care unit stay in critically ill patients Posterior quadratus lumborum versus caudal epidural block for perioperative analgesia in pediatric patients undergoing upper abdominal surgeries: Arandomized, double-blind trial
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1