{"title":"基于二元共沸工质的OTEC-ORC和涡轮性能改进","authors":"Q. Ma, Jie-guang Huang, Zezhou Gao, Hui Lu, Hongfeng Luo, Jingru Li, Zhongye Wu, Xinrang Feng","doi":"10.1155/2023/8892450","DOIUrl":null,"url":null,"abstract":"In this paper, the composition of binary nonazeotropic working fluids is explored from the perspective of improving OTEC-ORC efficiency, and the turbine is designed to accommodate with the working fluid. It is found that the OTEC-ORC using a R152a/R32 mixture as the working fluid is significantly higher than the OTEC-ORC thermal efficiency and system efficiency of the pure NH3, and the optimal composition of the mixed working fluid R152a/R32 is determined to be 85 : 15 with the thermal efficiency and the system efficiency of 2.8% and 1.7%, respectively, improving by 35.7% and 151.2% compared to the NH3 ORC. According to the determined working fluid, a one-dimensional (1-D) design and CFD simulation analysis simulation are carried out on the turbine. The 1-D calculation results are in good agreement with the three-dimensional (3-D) results. At the design point, the turbine output is 83.84 kW, and the isentropic efficiency is 87.53%. At the off-design point, turbines have better off-design performance, indicating that the designed turbine also has good adaptability.","PeriodicalId":13921,"journal":{"name":"International Journal of Chemical Engineering","volume":" ","pages":""},"PeriodicalIF":2.3000,"publicationDate":"2023-03-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Performance Improvement of OTEC-ORC and Turbine Based on Binary Zeotropic Working Fluid\",\"authors\":\"Q. Ma, Jie-guang Huang, Zezhou Gao, Hui Lu, Hongfeng Luo, Jingru Li, Zhongye Wu, Xinrang Feng\",\"doi\":\"10.1155/2023/8892450\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, the composition of binary nonazeotropic working fluids is explored from the perspective of improving OTEC-ORC efficiency, and the turbine is designed to accommodate with the working fluid. It is found that the OTEC-ORC using a R152a/R32 mixture as the working fluid is significantly higher than the OTEC-ORC thermal efficiency and system efficiency of the pure NH3, and the optimal composition of the mixed working fluid R152a/R32 is determined to be 85 : 15 with the thermal efficiency and the system efficiency of 2.8% and 1.7%, respectively, improving by 35.7% and 151.2% compared to the NH3 ORC. According to the determined working fluid, a one-dimensional (1-D) design and CFD simulation analysis simulation are carried out on the turbine. The 1-D calculation results are in good agreement with the three-dimensional (3-D) results. At the design point, the turbine output is 83.84 kW, and the isentropic efficiency is 87.53%. At the off-design point, turbines have better off-design performance, indicating that the designed turbine also has good adaptability.\",\"PeriodicalId\":13921,\"journal\":{\"name\":\"International Journal of Chemical Engineering\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2023-03-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Chemical Engineering\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1155/2023/8892450\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, CHEMICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Chemical Engineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1155/2023/8892450","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, CHEMICAL","Score":null,"Total":0}
Performance Improvement of OTEC-ORC and Turbine Based on Binary Zeotropic Working Fluid
In this paper, the composition of binary nonazeotropic working fluids is explored from the perspective of improving OTEC-ORC efficiency, and the turbine is designed to accommodate with the working fluid. It is found that the OTEC-ORC using a R152a/R32 mixture as the working fluid is significantly higher than the OTEC-ORC thermal efficiency and system efficiency of the pure NH3, and the optimal composition of the mixed working fluid R152a/R32 is determined to be 85 : 15 with the thermal efficiency and the system efficiency of 2.8% and 1.7%, respectively, improving by 35.7% and 151.2% compared to the NH3 ORC. According to the determined working fluid, a one-dimensional (1-D) design and CFD simulation analysis simulation are carried out on the turbine. The 1-D calculation results are in good agreement with the three-dimensional (3-D) results. At the design point, the turbine output is 83.84 kW, and the isentropic efficiency is 87.53%. At the off-design point, turbines have better off-design performance, indicating that the designed turbine also has good adaptability.
期刊介绍:
International Journal of Chemical Engineering publishes papers on technologies for the production, processing, transportation, and use of chemicals on a large scale. Studies typically relate to processes within chemical and energy industries, especially for production of food, pharmaceuticals, fuels, and chemical feedstocks. Topics of investigation cover plant design and operation, process design and analysis, control and reaction engineering, as well as hazard mitigation and safety measures.
As well as original research, International Journal of Chemical Engineering also publishes focused review articles that examine the state of the art, identify emerging trends, and suggest future directions for developing fields.