Rishiraj Adhikary, Dhruvi Lodhavia, Chris Francis, Rohit Patil, Tanmay Srivastava, Prerna Khanna, Nipun Batra, Joseph Breda, J. Peplinski, Shwetak N. Patel
{"title":"SpiroMask:使用消费级口罩测量肺功能","authors":"Rishiraj Adhikary, Dhruvi Lodhavia, Chris Francis, Rohit Patil, Tanmay Srivastava, Prerna Khanna, Nipun Batra, Joseph Breda, J. Peplinski, Shwetak N. Patel","doi":"10.1145/3570167","DOIUrl":null,"url":null,"abstract":"According to the World Health Organisation (WHO), 235 million people suffer from respiratory illnesses which causes four million deaths annually. Regular lung health monitoring can lead to prognoses about deteriorating lung health conditions. This article presents our system SpiroMask that retrofits a microphone in consumer-grade masks (N95 and cloth masks) for continuous lung health monitoring. We evaluate our approach on 48 participants (including 14 with lung health issues) and find that we can estimate parameters such as lung volume and respiration rate within the approved error range by the American Thoracic Society (ATS). Further, we show that our approach is robust to sensor placement inside the mask.","PeriodicalId":72043,"journal":{"name":"ACM transactions on computing for healthcare","volume":"4 1","pages":"1 - 34"},"PeriodicalIF":0.0000,"publicationDate":"2022-01-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"SpiroMask: Measuring Lung Function Using Consumer-Grade Masks\",\"authors\":\"Rishiraj Adhikary, Dhruvi Lodhavia, Chris Francis, Rohit Patil, Tanmay Srivastava, Prerna Khanna, Nipun Batra, Joseph Breda, J. Peplinski, Shwetak N. Patel\",\"doi\":\"10.1145/3570167\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"According to the World Health Organisation (WHO), 235 million people suffer from respiratory illnesses which causes four million deaths annually. Regular lung health monitoring can lead to prognoses about deteriorating lung health conditions. This article presents our system SpiroMask that retrofits a microphone in consumer-grade masks (N95 and cloth masks) for continuous lung health monitoring. We evaluate our approach on 48 participants (including 14 with lung health issues) and find that we can estimate parameters such as lung volume and respiration rate within the approved error range by the American Thoracic Society (ATS). Further, we show that our approach is robust to sensor placement inside the mask.\",\"PeriodicalId\":72043,\"journal\":{\"name\":\"ACM transactions on computing for healthcare\",\"volume\":\"4 1\",\"pages\":\"1 - 34\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-01-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACM transactions on computing for healthcare\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1145/3570167\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACM transactions on computing for healthcare","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1145/3570167","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
SpiroMask: Measuring Lung Function Using Consumer-Grade Masks
According to the World Health Organisation (WHO), 235 million people suffer from respiratory illnesses which causes four million deaths annually. Regular lung health monitoring can lead to prognoses about deteriorating lung health conditions. This article presents our system SpiroMask that retrofits a microphone in consumer-grade masks (N95 and cloth masks) for continuous lung health monitoring. We evaluate our approach on 48 participants (including 14 with lung health issues) and find that we can estimate parameters such as lung volume and respiration rate within the approved error range by the American Thoracic Society (ATS). Further, we show that our approach is robust to sensor placement inside the mask.