c2c12细胞桩环编织心肌组织工程支架的体外评价

Q4 Engineering Tekstil ve Muhendis Pub Date : 2022-12-30 DOI:10.7216/teksmuh.1221124
Derya Haroglu
{"title":"c2c12细胞桩环编织心肌组织工程支架的体外评价","authors":"Derya Haroglu","doi":"10.7216/teksmuh.1221124","DOIUrl":null,"url":null,"abstract":"Pile loop knitted scaffold has attracted attention for being used as a three dimensional (3D) biocompatible material particularly for the application of myocardial tissue engineering. In this research, nonintermingled, textured polyethylene terephthalate (PET) multifilament yarn with a filament count of 48 was used for producing a pile loop knit structure to investigate if structure could provide an appropriate microenvironment for the seeded murine C2C12 myoblasts in case of increasing in filament diameter (20.7 micron versus 9.1 micron from the previous study). The resulting structure had a pore network mainly consisting of macropores of 100-200 µm that were well interconnected with micropores (<90 µm). Furthermore, the mean values of the Young’s modulus of the structures at 20% strain were 240.67 kPa in the warp direction, and 85.73 kPa in the weft direction, which can be claimed not to be far from those declared in the literature for the human heart muscle. In addition, the cyclic loading-unloading test revealed no creep in the fabric after 100 cycles. According to the results of the WST-1 assay, the 48 filament-based scaffold was non-cytotoxic for C2C12 cells that were able to proliferate properly on the scaffold, which was visualized by SEM and confocal images. In this respect, pile loop knit structures keep promising results for being used as a cardiac patch.","PeriodicalId":35281,"journal":{"name":"Tekstil ve Muhendis","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-12-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"IN VITRO EVALUATION OF A PILE LOOP KNITTED SCAFFOLD FOR MYOCARDIAL TISSUE ENGINEERING USING C2C12 CELLS\",\"authors\":\"Derya Haroglu\",\"doi\":\"10.7216/teksmuh.1221124\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Pile loop knitted scaffold has attracted attention for being used as a three dimensional (3D) biocompatible material particularly for the application of myocardial tissue engineering. In this research, nonintermingled, textured polyethylene terephthalate (PET) multifilament yarn with a filament count of 48 was used for producing a pile loop knit structure to investigate if structure could provide an appropriate microenvironment for the seeded murine C2C12 myoblasts in case of increasing in filament diameter (20.7 micron versus 9.1 micron from the previous study). The resulting structure had a pore network mainly consisting of macropores of 100-200 µm that were well interconnected with micropores (<90 µm). Furthermore, the mean values of the Young’s modulus of the structures at 20% strain were 240.67 kPa in the warp direction, and 85.73 kPa in the weft direction, which can be claimed not to be far from those declared in the literature for the human heart muscle. In addition, the cyclic loading-unloading test revealed no creep in the fabric after 100 cycles. According to the results of the WST-1 assay, the 48 filament-based scaffold was non-cytotoxic for C2C12 cells that were able to proliferate properly on the scaffold, which was visualized by SEM and confocal images. In this respect, pile loop knit structures keep promising results for being used as a cardiac patch.\",\"PeriodicalId\":35281,\"journal\":{\"name\":\"Tekstil ve Muhendis\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-12-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Tekstil ve Muhendis\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.7216/teksmuh.1221124\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Engineering\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Tekstil ve Muhendis","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.7216/teksmuh.1221124","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 0

摘要

桩环编织支架作为一种三维生物相容性材料,尤其在心肌组织工程中的应用受到了广泛的关注。本研究采用长丝数为48的非混纺、织构聚对苯二甲酸乙二醇酯(PET)多长丝制作成绒圈编织结构,研究在长丝直径增加(20.7微米与先前研究的9.1微米相比)的情况下,该结构是否能为小鼠C2C12成肌细胞提供合适的微环境。所得到的结构具有一个主要由100-200µm的大孔组成的孔隙网络,这些大孔与<90µm的微孔连通良好。此外,在20%应变下,结构在经线方向的杨氏模量平均值为240.67 kPa,在经线方向的杨氏模量平均值为85.73 kPa,可以说与文献中对人体心肌的声明相差不远。此外,循环加载-卸载试验表明,织物经过100次循环后没有蠕变。根据WST-1检测结果,通过扫描电镜和共聚焦图像显示,48丝基支架对C2C12细胞无细胞毒性,C2C12细胞能够在支架上正常增殖。在这方面,桩环编织结构在心脏贴片方面保持着良好的效果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
IN VITRO EVALUATION OF A PILE LOOP KNITTED SCAFFOLD FOR MYOCARDIAL TISSUE ENGINEERING USING C2C12 CELLS
Pile loop knitted scaffold has attracted attention for being used as a three dimensional (3D) biocompatible material particularly for the application of myocardial tissue engineering. In this research, nonintermingled, textured polyethylene terephthalate (PET) multifilament yarn with a filament count of 48 was used for producing a pile loop knit structure to investigate if structure could provide an appropriate microenvironment for the seeded murine C2C12 myoblasts in case of increasing in filament diameter (20.7 micron versus 9.1 micron from the previous study). The resulting structure had a pore network mainly consisting of macropores of 100-200 µm that were well interconnected with micropores (<90 µm). Furthermore, the mean values of the Young’s modulus of the structures at 20% strain were 240.67 kPa in the warp direction, and 85.73 kPa in the weft direction, which can be claimed not to be far from those declared in the literature for the human heart muscle. In addition, the cyclic loading-unloading test revealed no creep in the fabric after 100 cycles. According to the results of the WST-1 assay, the 48 filament-based scaffold was non-cytotoxic for C2C12 cells that were able to proliferate properly on the scaffold, which was visualized by SEM and confocal images. In this respect, pile loop knit structures keep promising results for being used as a cardiac patch.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Tekstil ve Muhendis
Tekstil ve Muhendis Engineering-Industrial and Manufacturing Engineering
CiteScore
0.40
自引率
0.00%
发文量
12
期刊最新文献
PRODUCTION AND CHARACTERIZATION OF PHB, PHBV ELECTROSPUN FIBERS AND THEIR BLENDS COLOR REMOVAL OF DISPERSE DYEING WASTE WATER BY OZONE IN AN EXAMPLE DYEHAUSE GÖMLEK GİYİMİ İLE İLGİLİ TÜKETİCİ KONFOR DENEYİMLERİNİN VE TÜKETİCİ BEKLENTİLERİNİN İNCELENMESİ ENVIRONMENTALLY FRIENDLY ACOUSTIC PANEL DESIGN FROM CURTAIN WASTE YARN PULL-OUT AND DROP WEIGHT IMPACT PERFORMANCE OF SHEAR THICKENING FLUID IMPREGNATED BALLISTIC FABRICS
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1