{"title":"保护性覆层对垂直荷载交叉层压木材(CLT)墙板防火性能的影响","authors":"Muhammad Yasir, A. Macilwraith, C. O’Ceallaigh, K. Ruane","doi":"10.1080/24705314.2023.2189683","DOIUrl":null,"url":null,"abstract":"ABSTRACT  Cross-laminated timber (CLT) is a sustainable engineered wood product which is utilised in modern multi-storey timber buildings. The fire behaviour of timber structures is often a concern due to their combustible nature. In this paper, experimental fire testing of CLT panels made of Irish spruce was performed. This series of tests consisted of four vertically loaded CLT wall panels which were tested under Standard fire curves in the Structural Laboratory of Munster Technological University, Cork (MTU). To improve the fire performance of CLT panels, different types of protective claddings were used. The effectiveness of each system of protection has been stated particularly in terms of the delay in the start of charring of the CLT panels. The location of joints in the protective cladding was also analysed and was found to be a key factor in the fall-off time of the protective claddings. The results show that protective claddings made with Fireline gypsum plasterboard and a combination of plywood and Fireline gypsum plasterboard delayed the charring of CLT panels by as much as 30 and 44 min respectively. This paper analyses the detailed results of experimental fire testing and measures the charring rate and temperature distribution across the panels.","PeriodicalId":43844,"journal":{"name":"Journal of Structural Integrity and Maintenance","volume":null,"pages":null},"PeriodicalIF":3.0000,"publicationDate":"2023-04-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Effect of protective cladding on the fire performance of vertically loaded cross-laminated timber (CLT) wall panels\",\"authors\":\"Muhammad Yasir, A. Macilwraith, C. O’Ceallaigh, K. Ruane\",\"doi\":\"10.1080/24705314.2023.2189683\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"ABSTRACT  Cross-laminated timber (CLT) is a sustainable engineered wood product which is utilised in modern multi-storey timber buildings. The fire behaviour of timber structures is often a concern due to their combustible nature. In this paper, experimental fire testing of CLT panels made of Irish spruce was performed. This series of tests consisted of four vertically loaded CLT wall panels which were tested under Standard fire curves in the Structural Laboratory of Munster Technological University, Cork (MTU). To improve the fire performance of CLT panels, different types of protective claddings were used. The effectiveness of each system of protection has been stated particularly in terms of the delay in the start of charring of the CLT panels. The location of joints in the protective cladding was also analysed and was found to be a key factor in the fall-off time of the protective claddings. The results show that protective claddings made with Fireline gypsum plasterboard and a combination of plywood and Fireline gypsum plasterboard delayed the charring of CLT panels by as much as 30 and 44 min respectively. This paper analyses the detailed results of experimental fire testing and measures the charring rate and temperature distribution across the panels.\",\"PeriodicalId\":43844,\"journal\":{\"name\":\"Journal of Structural Integrity and Maintenance\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.0000,\"publicationDate\":\"2023-04-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Structural Integrity and Maintenance\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/24705314.2023.2189683\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, CIVIL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Structural Integrity and Maintenance","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/24705314.2023.2189683","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, CIVIL","Score":null,"Total":0}
引用次数: 1
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Effect of protective cladding on the fire performance of vertically loaded cross-laminated timber (CLT) wall panels
ABSTRACT  Cross-laminated timber (CLT) is a sustainable engineered wood product which is utilised in modern multi-storey timber buildings. The fire behaviour of timber structures is often a concern due to their combustible nature. In this paper, experimental fire testing of CLT panels made of Irish spruce was performed. This series of tests consisted of four vertically loaded CLT wall panels which were tested under Standard fire curves in the Structural Laboratory of Munster Technological University, Cork (MTU). To improve the fire performance of CLT panels, different types of protective claddings were used. The effectiveness of each system of protection has been stated particularly in terms of the delay in the start of charring of the CLT panels. The location of joints in the protective cladding was also analysed and was found to be a key factor in the fall-off time of the protective claddings. The results show that protective claddings made with Fireline gypsum plasterboard and a combination of plywood and Fireline gypsum plasterboard delayed the charring of CLT panels by as much as 30 and 44 min respectively. This paper analyses the detailed results of experimental fire testing and measures the charring rate and temperature distribution across the panels.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.90
自引率
9.50%
发文量
24
期刊最新文献
Influential factor analysis of slag-based engineered cementitious composites using Taguchi robust method Influence of corrosion-based section loss on morphology and tensile capacity of pre-stressing strands Application of electrical resistivity for estimating compressive strength of FRC at early-ages Evaluation and optimization of volume fraction and aspect ratio of Polyethylene Terephthalate (PET) fibers in self-compacting lightweight concrete Vulnerability assessment of tall isolated steel building under variable earthquake hazard levels using endurance time method
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1