盐雾试验后胶粘剂类型和金属基材对粘结接头附着力的影响

Q3 Materials Science Koroze a ochrana materialu Pub Date : 2018-05-01 DOI:10.1515/kom-2018-0006
K. Machalická, P. Pokorný, M. Vokáč
{"title":"盐雾试验后胶粘剂类型和金属基材对粘结接头附着力的影响","authors":"K. Machalická, P. Pokorný, M. Vokáč","doi":"10.1515/kom-2018-0006","DOIUrl":null,"url":null,"abstract":"Abstract This article was focused on the evaluation of neutral salt spray test effect (according to ISO 9124), procedure E4, on mechanical properties of load-bearing adhesive joints. The study also comprises the influence of substrate material (mild steel, aluminum alloys) and substrate surface roughness (verified by optical confocal microscopy). The experimental program contained acrylate-based adhesive and hybrid silicone polyurethane based adhesive which were applied in double lap joints loaded by shear.","PeriodicalId":17911,"journal":{"name":"Koroze a ochrana materialu","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2018-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Influence of the adhesive type and metal substrate on adhesion of bonded joints after salt spray test\",\"authors\":\"K. Machalická, P. Pokorný, M. Vokáč\",\"doi\":\"10.1515/kom-2018-0006\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract This article was focused on the evaluation of neutral salt spray test effect (according to ISO 9124), procedure E4, on mechanical properties of load-bearing adhesive joints. The study also comprises the influence of substrate material (mild steel, aluminum alloys) and substrate surface roughness (verified by optical confocal microscopy). The experimental program contained acrylate-based adhesive and hybrid silicone polyurethane based adhesive which were applied in double lap joints loaded by shear.\",\"PeriodicalId\":17911,\"journal\":{\"name\":\"Koroze a ochrana materialu\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Koroze a ochrana materialu\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1515/kom-2018-0006\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Materials Science\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Koroze a ochrana materialu","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1515/kom-2018-0006","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Materials Science","Score":null,"Total":0}
引用次数: 2

摘要

摘要本文主要研究了中性盐雾试验(ISO 9124)程序E4对承载胶粘剂接头力学性能的评价效果。该研究还包括衬底材料(低碳钢,铝合金)和衬底表面粗糙度的影响(通过光学共聚焦显微镜验证)。实验方案包括丙烯酸酯基胶粘剂和混合硅基聚氨酯基胶粘剂,分别应用于剪切载荷下的双搭接接头。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Influence of the adhesive type and metal substrate on adhesion of bonded joints after salt spray test
Abstract This article was focused on the evaluation of neutral salt spray test effect (according to ISO 9124), procedure E4, on mechanical properties of load-bearing adhesive joints. The study also comprises the influence of substrate material (mild steel, aluminum alloys) and substrate surface roughness (verified by optical confocal microscopy). The experimental program contained acrylate-based adhesive and hybrid silicone polyurethane based adhesive which were applied in double lap joints loaded by shear.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Koroze a ochrana materialu
Koroze a ochrana materialu Materials Science-Materials Science (all)
CiteScore
3.00
自引率
0.00%
发文量
8
审稿时长
14 weeks
期刊最新文献
Indoor corrosivity classification based on lead coupons Protective ability of lead corrosion products in indoor atmosphere with acetic acid vapours Anchorage length of patented wire cables in prestressed bridge girders Monitoring of the atmospheric corrosivity by resistive sensors Mitigation of chloride induced corrosion in reinforced concrete structures and its modeling
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1