I. Zaed, Francesca Faedo, S. Chibbaro, D. Cannizzaro, M. Tomei, F. Servadei, A. Cardia
{"title":"儿童自体和异体颅骨成形术术后并发症的发生率:文献系统综述","authors":"I. Zaed, Francesca Faedo, S. Chibbaro, D. Cannizzaro, M. Tomei, F. Servadei, A. Cardia","doi":"10.1159/000524874","DOIUrl":null,"url":null,"abstract":"Introduction: Cranial reconstruction (CR) is a neurosurgical procedure performed to restore the cranial vault after a decompressive craniectomy. There are contrasting reports from the literature about the complications related to the use of heterologous materials for CR in the pediatric population. In this study, the authors try to better define such a rate of adverse events for autologous and heterologous materials. Materials and Methods: A systematic review of articles published up to December 2021 was performed. Studies were included if they reported the specific use of cranioplasty materials following craniectomy in patients younger than 18 years of age and had a minimum follow-up of at least 1 year. Results: A total of 20 studies were selected. A total of 544 cases were included, of which 422 (77.6%) were with heterologous materials and 122 (22.4%) with autologous bone. The mean average age was 9.5 years. Polyetheretherketone and polymethylmethacrylate reported 29% and 33.3%, respectively, of complications, but only 3% and 5.6% of surgical revision. PHA reported a rate of 11.9%. Titanium reported 9.2% of complications and 4.1% of surgical revisions. Porous polyethylene had a complication rate of 36.4% and a revision rate of 0%. Conclusion: There is still no perfect material for CR. It seems that heterologous materials are superior to autologous bone for CR in children, and we may consider, whenever economic conditions will allow it, to use alloplastic material as first-line in small children.","PeriodicalId":54631,"journal":{"name":"Pediatric Neurosurgery","volume":"57 1","pages":"238 - 244"},"PeriodicalIF":0.9000,"publicationDate":"2022-05-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Prevalence of Postoperative Complications of Autologous and Heterologous Cranioplasty in the Pediatric Population: A Systematic Review of the Literature\",\"authors\":\"I. Zaed, Francesca Faedo, S. Chibbaro, D. Cannizzaro, M. Tomei, F. Servadei, A. Cardia\",\"doi\":\"10.1159/000524874\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Introduction: Cranial reconstruction (CR) is a neurosurgical procedure performed to restore the cranial vault after a decompressive craniectomy. There are contrasting reports from the literature about the complications related to the use of heterologous materials for CR in the pediatric population. In this study, the authors try to better define such a rate of adverse events for autologous and heterologous materials. Materials and Methods: A systematic review of articles published up to December 2021 was performed. Studies were included if they reported the specific use of cranioplasty materials following craniectomy in patients younger than 18 years of age and had a minimum follow-up of at least 1 year. Results: A total of 20 studies were selected. A total of 544 cases were included, of which 422 (77.6%) were with heterologous materials and 122 (22.4%) with autologous bone. The mean average age was 9.5 years. Polyetheretherketone and polymethylmethacrylate reported 29% and 33.3%, respectively, of complications, but only 3% and 5.6% of surgical revision. PHA reported a rate of 11.9%. Titanium reported 9.2% of complications and 4.1% of surgical revisions. Porous polyethylene had a complication rate of 36.4% and a revision rate of 0%. Conclusion: There is still no perfect material for CR. It seems that heterologous materials are superior to autologous bone for CR in children, and we may consider, whenever economic conditions will allow it, to use alloplastic material as first-line in small children.\",\"PeriodicalId\":54631,\"journal\":{\"name\":\"Pediatric Neurosurgery\",\"volume\":\"57 1\",\"pages\":\"238 - 244\"},\"PeriodicalIF\":0.9000,\"publicationDate\":\"2022-05-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Pediatric Neurosurgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1159/000524874\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CLINICAL NEUROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pediatric Neurosurgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1159/000524874","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
Prevalence of Postoperative Complications of Autologous and Heterologous Cranioplasty in the Pediatric Population: A Systematic Review of the Literature
Introduction: Cranial reconstruction (CR) is a neurosurgical procedure performed to restore the cranial vault after a decompressive craniectomy. There are contrasting reports from the literature about the complications related to the use of heterologous materials for CR in the pediatric population. In this study, the authors try to better define such a rate of adverse events for autologous and heterologous materials. Materials and Methods: A systematic review of articles published up to December 2021 was performed. Studies were included if they reported the specific use of cranioplasty materials following craniectomy in patients younger than 18 years of age and had a minimum follow-up of at least 1 year. Results: A total of 20 studies were selected. A total of 544 cases were included, of which 422 (77.6%) were with heterologous materials and 122 (22.4%) with autologous bone. The mean average age was 9.5 years. Polyetheretherketone and polymethylmethacrylate reported 29% and 33.3%, respectively, of complications, but only 3% and 5.6% of surgical revision. PHA reported a rate of 11.9%. Titanium reported 9.2% of complications and 4.1% of surgical revisions. Porous polyethylene had a complication rate of 36.4% and a revision rate of 0%. Conclusion: There is still no perfect material for CR. It seems that heterologous materials are superior to autologous bone for CR in children, and we may consider, whenever economic conditions will allow it, to use alloplastic material as first-line in small children.
期刊介绍:
Articles in ''Pediatric Neurosurgery'' strives to publish new information and observations in pediatric neurosurgery and the allied fields of neurology, neuroradiology and neuropathology as they relate to the etiology of neurologic diseases and the operative care of affected patients. In addition to experimental and clinical studies, the journal presents critical reviews which provide the reader with an update on selected topics as well as case histories and reports on advances in methodology and technique. This thought-provoking focus encourages dissemination of information from neurosurgeons and neuroscientists around the world that will be of interest to clinicians and researchers concerned with pediatric, congenital, and developmental diseases of the nervous system.