计算机断层扫描在眼眶外伤诊断中的现代能力

Dmitry V. Davydov, N. Serova, O. Pavlova
{"title":"计算机断层扫描在眼眶外伤诊断中的现代能力","authors":"Dmitry V. Davydov, N. Serova, O. Pavlova","doi":"10.17816/ov106092","DOIUrl":null,"url":null,"abstract":"BACKGROUND: Nowadays the problem of orbital trauma remains extremely relevant. Combined damage of several anatomical structures, globe injury, various clinical manifestations, the necessity of optimal surgical treatment require high-quality, timely diagnostics. Considering the current development of diagnostic equipment, postprocessing of CT data acquires the key role in order to obtain objective diagnostic information in patients with orbital trauma. \nAIM: Evaluation of the effectiveness of the developed methods for CT data assessing in patients with orbital trauma. \nMATERIALS AND METHODS: From 2016 to 2021 a total of 107 patients (100%) with orbital injuries were examined in Sechenov University clinics. All patients were distributed depending on the injury occurrence time: 50 patients (47%) in acute and subacute periods, 30 patients (28%) in the period of formation of post-traumatic deformities, 27 patients (25%) in the period of formed post-traumatic deformities. All patients (n = 107; 100%) underwent CT data analysis according to the developed protocol: analysis of bone and soft tissue trauma using a specialized algorithm, assessment of orbital volumes, evaluation of defects in the inferior orbital wall, examination of the globe position and of changes in the density of the orbital soft tissues. \nRESULTS: In the preoperative period the developed algorithm for orbital volumes measuring additionally revealed a post-traumatic increase in orbital volume in 21 patients (19%). The technique for the globe position assessing additionally revealed the risk of enophthalmos in 9 patients (8.1%), and in 1 case (0.9%) the suspicion of globe displacement was not confirmed. The defects of the inferior orbital wall were classified into small (n = 18; 17%), medium (n = 31; 29%) and large/total (n = 38; 35% and n = 20; 19%, respectively). In 88 patients (82%), the ratio of the defect to the entire inferior orbital wall was more than 6.65%, in 19 patients (18%) less than 6.65%. Changes in the density of the orbital soft tissues were as follows: soft tissue edema n = 60 (56%), soft tissue atrophy n = 28 (27%), hematoma of the orbital soft tissues n = 10 (9%), density was not changed n = 9 (8%). In the postoperative period, the developed methods for CT data processing revealed incomplete restoration of the orbital volume in 31 cases (29%), incomplete coverage of the inferior orbital wall defect in 38 cases (35%), globe displacement in 14 cases (13%), which was not determined by the standard CT data assessment without the specialized technique. In 7 cases (6%), a suspicion of an increase in the orbital volume was not confirmed by the developed methodology. \nCONCLUSION: The developed methods for measuring orbit volumes, assessing defects in the lower orbital wall, the globe position, and the condition of the orbital soft tissues provide statistically reliable additional diagnostic information about the patients condition and personalized approach for preoperative planning for each patient.","PeriodicalId":31539,"journal":{"name":"Ophthalmology Journal","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Modern capabilities of the computed tomography in orbital traumatic injuries diagnosis\",\"authors\":\"Dmitry V. Davydov, N. Serova, O. Pavlova\",\"doi\":\"10.17816/ov106092\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"BACKGROUND: Nowadays the problem of orbital trauma remains extremely relevant. Combined damage of several anatomical structures, globe injury, various clinical manifestations, the necessity of optimal surgical treatment require high-quality, timely diagnostics. Considering the current development of diagnostic equipment, postprocessing of CT data acquires the key role in order to obtain objective diagnostic information in patients with orbital trauma. \\nAIM: Evaluation of the effectiveness of the developed methods for CT data assessing in patients with orbital trauma. \\nMATERIALS AND METHODS: From 2016 to 2021 a total of 107 patients (100%) with orbital injuries were examined in Sechenov University clinics. All patients were distributed depending on the injury occurrence time: 50 patients (47%) in acute and subacute periods, 30 patients (28%) in the period of formation of post-traumatic deformities, 27 patients (25%) in the period of formed post-traumatic deformities. All patients (n = 107; 100%) underwent CT data analysis according to the developed protocol: analysis of bone and soft tissue trauma using a specialized algorithm, assessment of orbital volumes, evaluation of defects in the inferior orbital wall, examination of the globe position and of changes in the density of the orbital soft tissues. \\nRESULTS: In the preoperative period the developed algorithm for orbital volumes measuring additionally revealed a post-traumatic increase in orbital volume in 21 patients (19%). The technique for the globe position assessing additionally revealed the risk of enophthalmos in 9 patients (8.1%), and in 1 case (0.9%) the suspicion of globe displacement was not confirmed. The defects of the inferior orbital wall were classified into small (n = 18; 17%), medium (n = 31; 29%) and large/total (n = 38; 35% and n = 20; 19%, respectively). In 88 patients (82%), the ratio of the defect to the entire inferior orbital wall was more than 6.65%, in 19 patients (18%) less than 6.65%. Changes in the density of the orbital soft tissues were as follows: soft tissue edema n = 60 (56%), soft tissue atrophy n = 28 (27%), hematoma of the orbital soft tissues n = 10 (9%), density was not changed n = 9 (8%). In the postoperative period, the developed methods for CT data processing revealed incomplete restoration of the orbital volume in 31 cases (29%), incomplete coverage of the inferior orbital wall defect in 38 cases (35%), globe displacement in 14 cases (13%), which was not determined by the standard CT data assessment without the specialized technique. In 7 cases (6%), a suspicion of an increase in the orbital volume was not confirmed by the developed methodology. \\nCONCLUSION: The developed methods for measuring orbit volumes, assessing defects in the lower orbital wall, the globe position, and the condition of the orbital soft tissues provide statistically reliable additional diagnostic information about the patients condition and personalized approach for preoperative planning for each patient.\",\"PeriodicalId\":31539,\"journal\":{\"name\":\"Ophthalmology Journal\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-06-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ophthalmology Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.17816/ov106092\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ophthalmology Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17816/ov106092","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

背景:如今,眼眶创伤的问题仍然非常重要。几种解剖结构的联合损伤、眼球损伤、各种临床表现、最佳手术治疗的必要性都需要高质量、及时的诊断。考虑到当前诊断设备的发展,CT数据的后处理对于获得眼眶创伤患者的客观诊断信息起着关键作用。目的:评价所开发的眼眶创伤患者CT数据评估方法的有效性。材料和方法:从2016年到2021年,共有107名(100%)眼眶损伤患者在谢切诺夫大学诊所接受了检查。所有患者根据损伤发生时间进行分布:急性和亚急性期50例(47%),创伤后畸形形成期30例(28%),创伤前畸形形成期27例(25%)。所有患者(n=107;100%)根据制定的方案进行CT数据分析:使用专门算法分析骨和软组织创伤,评估眼眶体积,评估眶下壁缺陷,检查眼球位置和眼眶软组织密度变化。结果:在术前阶段,所开发的眼眶容积测量算法还显示,21名患者(19%)的眼眶容积在创伤后增加。眼球位置评估技术还显示了9名患者(8.1%)的眼球内陷风险,1名患者(0.9%)的眼球移位怀疑未得到证实。眶下壁缺损分为小(n=18;17%)、中(n=31;29%)和大/全(分别为n=38;35%和n=20;19%)。88例(82%)患者的缺损占整个眶下壁的比例大于6.65%,19例(18%)小于6.65%。眼眶软组织密度变化如下:软组织水肿n=60(56%),软组织萎缩n=28(27%),眼眶软组织血肿n=10(9%),密度不变n=9(8%)。在术后期间,所开发的CT数据处理方法显示,31例(29%)眼眶体积恢复不完全,38例(35%)眶下壁缺损覆盖不完全,14例(13%)眼球移位,这在没有专业技术的情况下无法通过标准CT数据评估来确定。在7例(6%)病例中,所开发的方法未证实眼眶体积增加的怀疑。结论:所开发的测量眼眶体积、评估眶下壁缺陷、眼球位置和眼眶软组织状况的方法提供了关于患者状况的统计可靠的额外诊断信息,并为每位患者的术前计划提供了个性化的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Modern capabilities of the computed tomography in orbital traumatic injuries diagnosis
BACKGROUND: Nowadays the problem of orbital trauma remains extremely relevant. Combined damage of several anatomical structures, globe injury, various clinical manifestations, the necessity of optimal surgical treatment require high-quality, timely diagnostics. Considering the current development of diagnostic equipment, postprocessing of CT data acquires the key role in order to obtain objective diagnostic information in patients with orbital trauma. AIM: Evaluation of the effectiveness of the developed methods for CT data assessing in patients with orbital trauma. MATERIALS AND METHODS: From 2016 to 2021 a total of 107 patients (100%) with orbital injuries were examined in Sechenov University clinics. All patients were distributed depending on the injury occurrence time: 50 patients (47%) in acute and subacute periods, 30 patients (28%) in the period of formation of post-traumatic deformities, 27 patients (25%) in the period of formed post-traumatic deformities. All patients (n = 107; 100%) underwent CT data analysis according to the developed protocol: analysis of bone and soft tissue trauma using a specialized algorithm, assessment of orbital volumes, evaluation of defects in the inferior orbital wall, examination of the globe position and of changes in the density of the orbital soft tissues. RESULTS: In the preoperative period the developed algorithm for orbital volumes measuring additionally revealed a post-traumatic increase in orbital volume in 21 patients (19%). The technique for the globe position assessing additionally revealed the risk of enophthalmos in 9 patients (8.1%), and in 1 case (0.9%) the suspicion of globe displacement was not confirmed. The defects of the inferior orbital wall were classified into small (n = 18; 17%), medium (n = 31; 29%) and large/total (n = 38; 35% and n = 20; 19%, respectively). In 88 patients (82%), the ratio of the defect to the entire inferior orbital wall was more than 6.65%, in 19 patients (18%) less than 6.65%. Changes in the density of the orbital soft tissues were as follows: soft tissue edema n = 60 (56%), soft tissue atrophy n = 28 (27%), hematoma of the orbital soft tissues n = 10 (9%), density was not changed n = 9 (8%). In the postoperative period, the developed methods for CT data processing revealed incomplete restoration of the orbital volume in 31 cases (29%), incomplete coverage of the inferior orbital wall defect in 38 cases (35%), globe displacement in 14 cases (13%), which was not determined by the standard CT data assessment without the specialized technique. In 7 cases (6%), a suspicion of an increase in the orbital volume was not confirmed by the developed methodology. CONCLUSION: The developed methods for measuring orbit volumes, assessing defects in the lower orbital wall, the globe position, and the condition of the orbital soft tissues provide statistically reliable additional diagnostic information about the patients condition and personalized approach for preoperative planning for each patient.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
0.40
自引率
0.00%
发文量
24
审稿时长
6 weeks
期刊最新文献
Unilateral idiopathic neuroretinitis following Pfizer-BioNTech COVID-19 vaccine: a case report Infraorbital nerve disturbance secondary to long-term cosmetic filler nodule migration at the lower eyelid The eye wipes with polyhexanide (HexaClean) in preoperative prophylaxis of cataract surgery Silicone oil retention sutures in a patient with open ocular trauma associated with aniridia and complicated retinal detachment: a case report Endophthalmitis — a rare but dangerous complication of intravitreal anti-VEGF injections
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1