抛光工艺对聚醚醚酮(PEEK)表面粗糙度和颜色稳定性的影响

IF 0.9 Q3 DENTISTRY, ORAL SURGERY & MEDICINE European Oral Research Pub Date : 2024-01-05 DOI:10.26650/eor.20231066580
Sezgi Cinel Sahin, Lamia Mutlu Sagesen
{"title":"抛光工艺对聚醚醚酮(PEEK)表面粗糙度和颜色稳定性的影响","authors":"Sezgi Cinel Sahin, Lamia Mutlu Sagesen","doi":"10.26650/eor.20231066580","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study aimed to evaluate the effects of different polishing protocols on the surface properties and color stability of the polyetheretherketone (PEEK).</p><p><strong>Materials and methods: </strong>A total of 96 disc-shaped specimens were fabricated from PEEK material and divided into 6 different groups: control (CN), ''Abraso-Starglanz'' polishing paste (A), ''Yildiz'' polishing paste (Y), ''Enhance'' polishing system (EN), ''Super snap'' polishing kit (SS), and silicone polisher (SP). Surface roughness (Ra) were measured with a profilometer and the surface topography was examined under scanning electron microscope. Color differences were measured with a spectrophotometer according to the CIEDE2000 (∆E00) formulation before and after coffee immersion. Data were statistically analyzed with Kruskall-Wallis and Spearman's correlation analysis (p<0.05, p<0.001).</p><p><strong>Results: </strong>A statistically significant difference was observed between the Ra measurements of the polishing protocols (p<0.001). Ra measurements except A, Y, and SS groups were found to be higher than the clinical acceptable threshold of surface roughness (0.20 μm). In ΔE00 measurements, statistically significant differences were observed between the CN and SP (p=0.041), EN (p=0.001), and A (p=0.002) polishing protocols. No correlation was found between Ra and color stability.</p><p><strong>Conclusion: </strong>Only in the A, Y and SS polishing protocols, Ra measurements were not found to be risky in terms of acceptable threshold of surface roughness. Polishing protocols have also generally failed to maintain the color stability. Considering the surface roughness and color stability, the ''Abraso-Starglanz'' paste may be suitable method for PEEK material.</p>","PeriodicalId":41993,"journal":{"name":"European Oral Research","volume":null,"pages":null},"PeriodicalIF":0.9000,"publicationDate":"2024-01-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10927709/pdf/","citationCount":"0","resultStr":"{\"title\":\"Effects of polishing protocols on the surface roughness and color stability of polyetheretherketone (PEEK).\",\"authors\":\"Sezgi Cinel Sahin, Lamia Mutlu Sagesen\",\"doi\":\"10.26650/eor.20231066580\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>This study aimed to evaluate the effects of different polishing protocols on the surface properties and color stability of the polyetheretherketone (PEEK).</p><p><strong>Materials and methods: </strong>A total of 96 disc-shaped specimens were fabricated from PEEK material and divided into 6 different groups: control (CN), ''Abraso-Starglanz'' polishing paste (A), ''Yildiz'' polishing paste (Y), ''Enhance'' polishing system (EN), ''Super snap'' polishing kit (SS), and silicone polisher (SP). Surface roughness (Ra) were measured with a profilometer and the surface topography was examined under scanning electron microscope. Color differences were measured with a spectrophotometer according to the CIEDE2000 (∆E00) formulation before and after coffee immersion. Data were statistically analyzed with Kruskall-Wallis and Spearman's correlation analysis (p<0.05, p<0.001).</p><p><strong>Results: </strong>A statistically significant difference was observed between the Ra measurements of the polishing protocols (p<0.001). Ra measurements except A, Y, and SS groups were found to be higher than the clinical acceptable threshold of surface roughness (0.20 μm). In ΔE00 measurements, statistically significant differences were observed between the CN and SP (p=0.041), EN (p=0.001), and A (p=0.002) polishing protocols. No correlation was found between Ra and color stability.</p><p><strong>Conclusion: </strong>Only in the A, Y and SS polishing protocols, Ra measurements were not found to be risky in terms of acceptable threshold of surface roughness. Polishing protocols have also generally failed to maintain the color stability. Considering the surface roughness and color stability, the ''Abraso-Starglanz'' paste may be suitable method for PEEK material.</p>\",\"PeriodicalId\":41993,\"journal\":{\"name\":\"European Oral Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.9000,\"publicationDate\":\"2024-01-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10927709/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Oral Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.26650/eor.20231066580\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Oral Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.26650/eor.20231066580","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的:本研究旨在评估不同抛光方案对聚醚醚酮(PEEK)表面特性和颜色稳定性的影响:用 PEEK 材料制作了 96 个圆盘状试样,并将其分为 6 组:对照组(CN)、"Abraso-Starglanz "抛光膏(A)、"Yildiz "抛光膏(Y)、"Enhance "抛光系统(EN)、"Super snap "抛光套件(SS)和硅胶抛光机(SP)。使用轮廓仪测量表面粗糙度(Ra),并在扫描电子显微镜下检查表面形貌。用分光光度计按照 CIEDE2000 (∆E00) 配方测量浸泡咖啡前后的色差。数据采用 Kruskall-Wallis 和 Spearman 相关分析法进行统计分析(pResults:抛光方案的 Ra 测量值之间存在明显的统计学差异(p 结论:只有在 A、Y 和 SS 抛光方案中,Ra 测量值在可接受的表面粗糙度阈值方面没有风险。抛光方案一般也无法保持颜色的稳定性。考虑到表面粗糙度和颜色稳定性,"Abraso-Starglanz "抛光膏可能是适用于 PEEK 材料的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Effects of polishing protocols on the surface roughness and color stability of polyetheretherketone (PEEK).

Purpose: This study aimed to evaluate the effects of different polishing protocols on the surface properties and color stability of the polyetheretherketone (PEEK).

Materials and methods: A total of 96 disc-shaped specimens were fabricated from PEEK material and divided into 6 different groups: control (CN), ''Abraso-Starglanz'' polishing paste (A), ''Yildiz'' polishing paste (Y), ''Enhance'' polishing system (EN), ''Super snap'' polishing kit (SS), and silicone polisher (SP). Surface roughness (Ra) were measured with a profilometer and the surface topography was examined under scanning electron microscope. Color differences were measured with a spectrophotometer according to the CIEDE2000 (∆E00) formulation before and after coffee immersion. Data were statistically analyzed with Kruskall-Wallis and Spearman's correlation analysis (p<0.05, p<0.001).

Results: A statistically significant difference was observed between the Ra measurements of the polishing protocols (p<0.001). Ra measurements except A, Y, and SS groups were found to be higher than the clinical acceptable threshold of surface roughness (0.20 μm). In ΔE00 measurements, statistically significant differences were observed between the CN and SP (p=0.041), EN (p=0.001), and A (p=0.002) polishing protocols. No correlation was found between Ra and color stability.

Conclusion: Only in the A, Y and SS polishing protocols, Ra measurements were not found to be risky in terms of acceptable threshold of surface roughness. Polishing protocols have also generally failed to maintain the color stability. Considering the surface roughness and color stability, the ''Abraso-Starglanz'' paste may be suitable method for PEEK material.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
European Oral Research
European Oral Research DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
1.60
自引率
0.00%
发文量
23
审稿时长
12 weeks
期刊最新文献
The antimicrobial effect of R-limonene and its nano emulsion on Enterococcus faecalis - In vitro study The effect of ozone water disinfection on color stability of nanoparticles reinforced maxillofacial silicones Finite element analysis of stresses on the skull base caused by trauma during sinus lift with mallet and osteotome Management of jump space in immediate implants with and without demineralised freeze dried bone allograft: a randomised controlled trial The influence of toluidine blue staining on decision-making for the selection of biopsy sites in oral disorders
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1