{"title":"破乳剂提取后原子吸收光谱法测定慢性肾病人肠内营养食品中金属元素","authors":"Maiara Maziero, C. Viana","doi":"10.1080/00387010.2022.2119253","DOIUrl":null,"url":null,"abstract":"Abstract This article describes the analysis of aluminum (Al), cadmium (Cd), copper (Cu), molybdenum (Mo), and lead (Pb) in foods for enteral nutrition of chronic renal patients by high-resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS GFAAS) after extraction induced by emulsion breaking. The following wavelengths were used for the detection of analytes 309.2713 nm for Al, 228.8018 nm for Cd, 324.7540 nm for Cu, 313.2594 nm for Mo, and 217.0005 nm for Pb. The detection limits for the methods were 0.022 mg kg−1 for Al, 0.0003 mg kg−1 for Cd, 0.001 mg kg−1 for Cu, 0.009 mg kg−1 for Mo, and 0.002 mg kg−1 for Pb. The precision ranged from 7.3% to 7.8%, 5.1% to 6.3%, 2.5% to 3.8%, 2.8% to 3.4%, and 6.2% to 7.3% for Al, Cd, Cu, Mo, and Pb, respectively. The accuracy of the method was evaluated through recovery tests, which ranged from 92.2% for Cd to 107.2% for Al. Cadmium concentrations in analyzed samples are below the limit allowed by Brazilian legislation (0.01 mg kg−1). However, two samples presented Pb concentration (samples 4 and 5) above the allowed limit (0.01 mg kg−1). Furthermore, all samples analyzed in this work showed relatively considerable quantities of Al (0.72–1.66 mg kg−1), and the concentrations of Cu (samples 3 and 4) and Mo (samples 1 and 5) were obtained were higher than those presented by the manufacturers. The proposed methods for the quantitative determination of the analytes of interest by HR-CS GFAAS after extraction induced by emulsion breaking in foods for enteral nutrition of chronic renal patients proved to be simple, fast, and efficient.","PeriodicalId":21953,"journal":{"name":"Spectroscopy Letters","volume":"55 1","pages":"534 - 545"},"PeriodicalIF":1.1000,"publicationDate":"2022-09-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Determination of metallic elements in foods for enteral nutrition of chronic renal patients by atomic absorption spectrometry after extraction induced by emulsion breaking\",\"authors\":\"Maiara Maziero, C. Viana\",\"doi\":\"10.1080/00387010.2022.2119253\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract This article describes the analysis of aluminum (Al), cadmium (Cd), copper (Cu), molybdenum (Mo), and lead (Pb) in foods for enteral nutrition of chronic renal patients by high-resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS GFAAS) after extraction induced by emulsion breaking. The following wavelengths were used for the detection of analytes 309.2713 nm for Al, 228.8018 nm for Cd, 324.7540 nm for Cu, 313.2594 nm for Mo, and 217.0005 nm for Pb. The detection limits for the methods were 0.022 mg kg−1 for Al, 0.0003 mg kg−1 for Cd, 0.001 mg kg−1 for Cu, 0.009 mg kg−1 for Mo, and 0.002 mg kg−1 for Pb. The precision ranged from 7.3% to 7.8%, 5.1% to 6.3%, 2.5% to 3.8%, 2.8% to 3.4%, and 6.2% to 7.3% for Al, Cd, Cu, Mo, and Pb, respectively. The accuracy of the method was evaluated through recovery tests, which ranged from 92.2% for Cd to 107.2% for Al. Cadmium concentrations in analyzed samples are below the limit allowed by Brazilian legislation (0.01 mg kg−1). However, two samples presented Pb concentration (samples 4 and 5) above the allowed limit (0.01 mg kg−1). Furthermore, all samples analyzed in this work showed relatively considerable quantities of Al (0.72–1.66 mg kg−1), and the concentrations of Cu (samples 3 and 4) and Mo (samples 1 and 5) were obtained were higher than those presented by the manufacturers. The proposed methods for the quantitative determination of the analytes of interest by HR-CS GFAAS after extraction induced by emulsion breaking in foods for enteral nutrition of chronic renal patients proved to be simple, fast, and efficient.\",\"PeriodicalId\":21953,\"journal\":{\"name\":\"Spectroscopy Letters\",\"volume\":\"55 1\",\"pages\":\"534 - 545\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2022-09-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Spectroscopy Letters\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1080/00387010.2022.2119253\",\"RegionNum\":4,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"SPECTROSCOPY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Spectroscopy Letters","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1080/00387010.2022.2119253","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"SPECTROSCOPY","Score":null,"Total":0}
引用次数: 1
摘要
摘要采用高分辨率连续源石墨炉原子吸收光谱法(HR-CS GFAAS)对慢性肾病患者肠内营养食品中的铝(Al)、镉(Cd)、铜(Cu)、钼(Mo)和铅(Pb)进行了乳破诱导提取后的分析。Al的检测波长为309.2713 nm, Cd为228.8018 nm, Cu为324.7540 nm, Mo为313.2594 nm, Pb为217.0005 nm。方法的检出限分别为:Al 0.022 mg kg - 1、Cd 0.0003 mg kg - 1、Cu 0.001 mg kg - 1、Mo 0.009 mg kg - 1、Pb 0.002 mg kg - 1。Al、Cd、Cu、Mo、Pb的精密度分别为7.3% ~ 7.8%、5.1% ~ 6.3%、2.5% ~ 3.8%、2.8% ~ 3.4%和6.2% ~ 7.3%。通过回收率测试评估了该方法的准确性,Cd的回收率为92.2%,Al的回收率为107.2%。分析样品中的镉浓度低于巴西立法允许的限值(0.01 mg kg - 1)。然而,两个样品(样品4和样品5)的铅浓度超过了允许限量(0.01 mg kg - 1)。此外,在本工作中分析的所有样品均显示出相当数量的Al (0.72-1.66 mg kg - 1),并且获得的Cu(样品3和4)和Mo(样品1和5)的浓度高于制造商提供的浓度。建立了慢性肾脏患者肠内营养食品中破乳诱导提取后的HR-CS GFAAS定量测定目的分析物的方法,简便、快速、高效。
Determination of metallic elements in foods for enteral nutrition of chronic renal patients by atomic absorption spectrometry after extraction induced by emulsion breaking
Abstract This article describes the analysis of aluminum (Al), cadmium (Cd), copper (Cu), molybdenum (Mo), and lead (Pb) in foods for enteral nutrition of chronic renal patients by high-resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS GFAAS) after extraction induced by emulsion breaking. The following wavelengths were used for the detection of analytes 309.2713 nm for Al, 228.8018 nm for Cd, 324.7540 nm for Cu, 313.2594 nm for Mo, and 217.0005 nm for Pb. The detection limits for the methods were 0.022 mg kg−1 for Al, 0.0003 mg kg−1 for Cd, 0.001 mg kg−1 for Cu, 0.009 mg kg−1 for Mo, and 0.002 mg kg−1 for Pb. The precision ranged from 7.3% to 7.8%, 5.1% to 6.3%, 2.5% to 3.8%, 2.8% to 3.4%, and 6.2% to 7.3% for Al, Cd, Cu, Mo, and Pb, respectively. The accuracy of the method was evaluated through recovery tests, which ranged from 92.2% for Cd to 107.2% for Al. Cadmium concentrations in analyzed samples are below the limit allowed by Brazilian legislation (0.01 mg kg−1). However, two samples presented Pb concentration (samples 4 and 5) above the allowed limit (0.01 mg kg−1). Furthermore, all samples analyzed in this work showed relatively considerable quantities of Al (0.72–1.66 mg kg−1), and the concentrations of Cu (samples 3 and 4) and Mo (samples 1 and 5) were obtained were higher than those presented by the manufacturers. The proposed methods for the quantitative determination of the analytes of interest by HR-CS GFAAS after extraction induced by emulsion breaking in foods for enteral nutrition of chronic renal patients proved to be simple, fast, and efficient.
期刊介绍:
Spectroscopy Letters provides vital coverage of all types of spectroscopy across all the disciplines where they are used—including novel work in fundamental spectroscopy, applications, diagnostics and instrumentation. The audience is intended to be all practicing spectroscopists across all scientific (and some engineering) disciplines, including: physics, chemistry, biology, instrumentation science, and pharmaceutical science.