X射线荧光法测定铁矿石中铁和成岩元素总量样品制备技术和基质效应校正方法的比较

Q4 Chemistry Analitika i Kontrol Pub Date : 2020-06-22 DOI:10.15826/analitika.2020.24.2.005
V. Chubarov, Elena I. Borkhonova, A. Amosova
{"title":"X射线荧光法测定铁矿石中铁和成岩元素总量样品制备技术和基质效应校正方法的比较","authors":"V. Chubarov, Elena I. Borkhonova, A. Amosova","doi":"10.15826/analitika.2020.24.2.005","DOIUrl":null,"url":null,"abstract":"The genesis of deposits determines wide variations in the mineral and chemical composition of iron ores. It is necessary to determine the content of not only the main ore element (Fe), but also the main rock-forming elements, especially those that affect the quality of the product obtained from the ore (for example, P and Mn). When determining Fe, Mg, Al, Si, P, Ca, Ti, and Mn in iron ores by wavelength-dispersive X-ray fluorescence analysis, two common sample preparation techniques were compared: pressing powder samples on a boric acid substrate and homogenization of calcined sample by fusion with lithium tetraborate. For each method, the repeatability of the measurement of analytical lines was evaluated, calibration equations were constructed using certified reference materials of iron ores of various types and two methods for matrix effects correction (fundamental parameters and empirical intensities) were compared. Iron ores samples from the Korshunovskoye, Rudnogorskoye and Tatyaninskoye deposits of the Angarsk ore province (north of the Irkutsk region and southeast of the Krasnoyarsk Krai) were analyzed by the certified atomic absorption and spectrophotometric techniques, and the results were compared with those obtained by X-ray fluorescence analysis. For the main ore element (Fe) and some rock-forming elements (Mg, Al, Si, P) determination, the fusion technique provided a smaller error, however, both techniques could be used to determine Ca, Ti, and Mn. The choice of the sample preparation technique for wavelength-dispersive X-ray fluorescence analysis of iron ores should be based on the appropriateness of the financial and labor costs and the necessary accuracy of the analysis. Keywords : wavelength-dispersive X-ray fluorescence analysis, iron ores, rock-forming elements, borate glasses, matrix effects correction DOI: http://dx.doi.org/10.15826/analitika.2020.24.2.005 Victor M. Chubarov 1 , Elena I. Borkhonova 2 , Alena A. Amosova 1 1 Vinogradov Institute of Geochemistry, SB RAS, 1 А Favorsky st., Irkutsk 664033, Russian Federation 2 Irkutsk State University, 1 Karl Marx st., Irkutsk 664003, Russian Federation","PeriodicalId":37743,"journal":{"name":"Analitika i Kontrol","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2020-06-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Comparison of sample preparation techniques and matrix effects correction methods for X-ray fluorescence determination of total iron and rock-forming elements in iron ores\",\"authors\":\"V. Chubarov, Elena I. Borkhonova, A. Amosova\",\"doi\":\"10.15826/analitika.2020.24.2.005\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The genesis of deposits determines wide variations in the mineral and chemical composition of iron ores. It is necessary to determine the content of not only the main ore element (Fe), but also the main rock-forming elements, especially those that affect the quality of the product obtained from the ore (for example, P and Mn). When determining Fe, Mg, Al, Si, P, Ca, Ti, and Mn in iron ores by wavelength-dispersive X-ray fluorescence analysis, two common sample preparation techniques were compared: pressing powder samples on a boric acid substrate and homogenization of calcined sample by fusion with lithium tetraborate. For each method, the repeatability of the measurement of analytical lines was evaluated, calibration equations were constructed using certified reference materials of iron ores of various types and two methods for matrix effects correction (fundamental parameters and empirical intensities) were compared. Iron ores samples from the Korshunovskoye, Rudnogorskoye and Tatyaninskoye deposits of the Angarsk ore province (north of the Irkutsk region and southeast of the Krasnoyarsk Krai) were analyzed by the certified atomic absorption and spectrophotometric techniques, and the results were compared with those obtained by X-ray fluorescence analysis. For the main ore element (Fe) and some rock-forming elements (Mg, Al, Si, P) determination, the fusion technique provided a smaller error, however, both techniques could be used to determine Ca, Ti, and Mn. The choice of the sample preparation technique for wavelength-dispersive X-ray fluorescence analysis of iron ores should be based on the appropriateness of the financial and labor costs and the necessary accuracy of the analysis. Keywords : wavelength-dispersive X-ray fluorescence analysis, iron ores, rock-forming elements, borate glasses, matrix effects correction DOI: http://dx.doi.org/10.15826/analitika.2020.24.2.005 Victor M. Chubarov 1 , Elena I. Borkhonova 2 , Alena A. Amosova 1 1 Vinogradov Institute of Geochemistry, SB RAS, 1 А Favorsky st., Irkutsk 664033, Russian Federation 2 Irkutsk State University, 1 Karl Marx st., Irkutsk 664003, Russian Federation\",\"PeriodicalId\":37743,\"journal\":{\"name\":\"Analitika i Kontrol\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-06-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Analitika i Kontrol\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.15826/analitika.2020.24.2.005\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Chemistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analitika i Kontrol","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15826/analitika.2020.24.2.005","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Chemistry","Score":null,"Total":0}
引用次数: 1

摘要

矿床的成因决定了铁矿石矿物和化学成分的广泛变化。不仅需要确定主要矿石元素(Fe)的含量,还需要确定主要岩石形成元素的含量,特别是那些影响从矿石中获得的产品质量的元素(例如P和Mn)。在用波长色散X射线荧光分析法测定铁矿石中的Fe、Mg、Al、Si、P、Ca、Ti和Mn时,比较了两种常用的样品制备技术:将粉末样品压制在硼酸基底上和将煅烧样品与四硼酸锂熔融均匀化。对于每种方法,评估分析线测量的可重复性,使用各种类型铁矿石的认证参考材料构建校准方程,并比较两种矩阵效应校正方法(基本参数和经验强度)。采用经认证的原子吸收和分光光度法对安加尔斯克矿石省(伊尔库茨克地区北部和克拉斯诺亚尔斯克边疆区东南部)Korshunovskoye、Rudnogorskoye和Tatyaninskoye矿床的铁矿石样品进行了分析,并将结果与X射线荧光分析结果进行了比较。对于主要矿石元素(Fe)和一些岩石形成元素(Mg、Al、Si、P)的测定,融合技术提供了较小的误差,然而,这两种技术都可以用于测定Ca、Ti和Mn。铁矿石波长色散X射线荧光分析样品制备技术的选择应基于财务和人力成本的适当性以及分析的必要准确性。关键词:波长色散X射线荧光分析,铁矿石,岩石形成元素,硼酸盐玻璃,基质效应校正DOI:http://dx.doi.org/10.15826/analitika.2020.24.2.005Victor M.Chubarov 1,Elena I.Borkhonova 2,Alena A.Amosova 1 1维诺格拉多夫地球化学研究所,SB RAS,1АFavorsky街,伊尔库茨克664033,俄罗斯联邦2伊尔库茨克州立大学,1 Karl Marx街,伊尔库茨克664003,俄罗斯联邦
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Comparison of sample preparation techniques and matrix effects correction methods for X-ray fluorescence determination of total iron and rock-forming elements in iron ores
The genesis of deposits determines wide variations in the mineral and chemical composition of iron ores. It is necessary to determine the content of not only the main ore element (Fe), but also the main rock-forming elements, especially those that affect the quality of the product obtained from the ore (for example, P and Mn). When determining Fe, Mg, Al, Si, P, Ca, Ti, and Mn in iron ores by wavelength-dispersive X-ray fluorescence analysis, two common sample preparation techniques were compared: pressing powder samples on a boric acid substrate and homogenization of calcined sample by fusion with lithium tetraborate. For each method, the repeatability of the measurement of analytical lines was evaluated, calibration equations were constructed using certified reference materials of iron ores of various types and two methods for matrix effects correction (fundamental parameters and empirical intensities) were compared. Iron ores samples from the Korshunovskoye, Rudnogorskoye and Tatyaninskoye deposits of the Angarsk ore province (north of the Irkutsk region and southeast of the Krasnoyarsk Krai) were analyzed by the certified atomic absorption and spectrophotometric techniques, and the results were compared with those obtained by X-ray fluorescence analysis. For the main ore element (Fe) and some rock-forming elements (Mg, Al, Si, P) determination, the fusion technique provided a smaller error, however, both techniques could be used to determine Ca, Ti, and Mn. The choice of the sample preparation technique for wavelength-dispersive X-ray fluorescence analysis of iron ores should be based on the appropriateness of the financial and labor costs and the necessary accuracy of the analysis. Keywords : wavelength-dispersive X-ray fluorescence analysis, iron ores, rock-forming elements, borate glasses, matrix effects correction DOI: http://dx.doi.org/10.15826/analitika.2020.24.2.005 Victor M. Chubarov 1 , Elena I. Borkhonova 2 , Alena A. Amosova 1 1 Vinogradov Institute of Geochemistry, SB RAS, 1 А Favorsky st., Irkutsk 664033, Russian Federation 2 Irkutsk State University, 1 Karl Marx st., Irkutsk 664003, Russian Federation
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Analitika i Kontrol
Analitika i Kontrol Chemistry-Analytical Chemistry
CiteScore
0.90
自引率
0.00%
发文量
15
期刊介绍: Analitika i Kontrol is a scientific journal covering theoretical and applied aspects of analytical chemistry and analytical control, published since autumn 1997. Founder and publisher of the journal is the Ural Federal University named after the first President of Russia Boris Yeltsin (UrFU, Ekaterinburg).
期刊最新文献
Electrophoretic determination of carboxylic acids in blood serum with intracapillary concentration Fluorescence of anisotropic primary X-ray radiation Selection of the parameters of a multicapillary column for portable gas analyzers by Kovach indices Differentiation of oil samples by isomeric composition of paraffins using cluster analysis methods Important features of retention indices determination in reversed-phase high performance liquid chromatography
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1