智能电网中基于高速电力线载波和GA‐ANN的配电站区电压质量分析方法

IF 2.4 Q2 ENGINEERING, ELECTRICAL & ELECTRONIC IET Smart Grid Pub Date : 2023-04-17 DOI:10.1049/stg2.12112
Hanjun Deng, Shuai Yang, Rui Huang, Mouhai Liu, Yeqin Ma, Yinghai Xie
{"title":"智能电网中基于高速电力线载波和GA‐ANN的配电站区电压质量分析方法","authors":"Hanjun Deng,&nbsp;Shuai Yang,&nbsp;Rui Huang,&nbsp;Mouhai Liu,&nbsp;Yeqin Ma,&nbsp;Yinghai Xie","doi":"10.1049/stg2.12112","DOIUrl":null,"url":null,"abstract":"<p>Aiming at the problem that most of the existing methods cannot obtain and accurately analyse the voltage quality of distribution network in time, a method for monitoring and analysing the voltage quality of distribution station area based on high-speed power line carrier under the power Internet of Things (PIoT) architecture in smart grid is proposed. Firstly, based on the PIoT architecture, a monitoring system for the distribution station area is designed, which realises the reliable monitoring of the voltage in the station area through the information interaction of the sensing layer, the network layer, the platform layer and the application layer. Then, the high-speed power line carrier is used to realise the rapid monitoring and collection of the station data, which improves the quality of basic data, and the principal component analysis method is used to extract the voltage quality characteristics and reduce the dimension. Finally, genetic algorithm (GA) is used to optimise the training of artificial neural network (ANN) to obtain the best improved GA-ANN network model. It is used to analyse the voltage quality feature set, which further improves the accuracy of obtaining voltage quality anomalies and related reasons. Based on the established distribution station area, the proposed method is experimentally demonstrated. The results show that the accuracy of voltage quality anomaly monitoring and analysis exceeds 99.5% and 97% respectively, and the average accuracy of low-voltage cause analysis reaches 97.83%, laying a theoretical foundation for building a strong distribution network.</p>","PeriodicalId":36490,"journal":{"name":"IET Smart Grid","volume":null,"pages":null},"PeriodicalIF":2.4000,"publicationDate":"2023-04-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1049/stg2.12112","citationCount":"0","resultStr":"{\"title\":\"Analysis method of voltage quality in distribution station area based on high-speed power line carrier and GA-ANN in smart grid\",\"authors\":\"Hanjun Deng,&nbsp;Shuai Yang,&nbsp;Rui Huang,&nbsp;Mouhai Liu,&nbsp;Yeqin Ma,&nbsp;Yinghai Xie\",\"doi\":\"10.1049/stg2.12112\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Aiming at the problem that most of the existing methods cannot obtain and accurately analyse the voltage quality of distribution network in time, a method for monitoring and analysing the voltage quality of distribution station area based on high-speed power line carrier under the power Internet of Things (PIoT) architecture in smart grid is proposed. Firstly, based on the PIoT architecture, a monitoring system for the distribution station area is designed, which realises the reliable monitoring of the voltage in the station area through the information interaction of the sensing layer, the network layer, the platform layer and the application layer. Then, the high-speed power line carrier is used to realise the rapid monitoring and collection of the station data, which improves the quality of basic data, and the principal component analysis method is used to extract the voltage quality characteristics and reduce the dimension. Finally, genetic algorithm (GA) is used to optimise the training of artificial neural network (ANN) to obtain the best improved GA-ANN network model. It is used to analyse the voltage quality feature set, which further improves the accuracy of obtaining voltage quality anomalies and related reasons. Based on the established distribution station area, the proposed method is experimentally demonstrated. The results show that the accuracy of voltage quality anomaly monitoring and analysis exceeds 99.5% and 97% respectively, and the average accuracy of low-voltage cause analysis reaches 97.83%, laying a theoretical foundation for building a strong distribution network.</p>\",\"PeriodicalId\":36490,\"journal\":{\"name\":\"IET Smart Grid\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.4000,\"publicationDate\":\"2023-04-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1049/stg2.12112\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IET Smart Grid\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1049/stg2.12112\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IET Smart Grid","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1049/stg2.12112","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

摘要

针对现有方法大多不能及时获取和准确分析配电网电压质量的问题,提出了一种智能电网中电力物联网(PIoT)架构下基于高速电力线载波的配电站区域电压质量监测与分析方法。首先,基于PIoT架构设计了配电站区监测系统,通过传感层、网络层、平台层和应用层的信息交互,实现了对配电站区电压的可靠监测。然后,利用高速电力线载波实现对台站数据的快速监测和采集,提高了基础数据的质量,并利用主成分分析方法提取电压质量特征并进行降维;最后,利用遗传算法(GA)对人工神经网络(ANN)的训练进行优化,得到最佳的改进GA-ANN网络模型。将其用于分析电压质量特征集,进一步提高了获取电压质量异常及其原因的准确性。基于已建立的配电站区域,对该方法进行了实验验证。结果表明,电压质量异常监测和分析准确率分别超过99.5%和97%,低压原因分析平均准确率达到97.83%,为建设强大的配电网奠定了理论基础。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Analysis method of voltage quality in distribution station area based on high-speed power line carrier and GA-ANN in smart grid

Aiming at the problem that most of the existing methods cannot obtain and accurately analyse the voltage quality of distribution network in time, a method for monitoring and analysing the voltage quality of distribution station area based on high-speed power line carrier under the power Internet of Things (PIoT) architecture in smart grid is proposed. Firstly, based on the PIoT architecture, a monitoring system for the distribution station area is designed, which realises the reliable monitoring of the voltage in the station area through the information interaction of the sensing layer, the network layer, the platform layer and the application layer. Then, the high-speed power line carrier is used to realise the rapid monitoring and collection of the station data, which improves the quality of basic data, and the principal component analysis method is used to extract the voltage quality characteristics and reduce the dimension. Finally, genetic algorithm (GA) is used to optimise the training of artificial neural network (ANN) to obtain the best improved GA-ANN network model. It is used to analyse the voltage quality feature set, which further improves the accuracy of obtaining voltage quality anomalies and related reasons. Based on the established distribution station area, the proposed method is experimentally demonstrated. The results show that the accuracy of voltage quality anomaly monitoring and analysis exceeds 99.5% and 97% respectively, and the average accuracy of low-voltage cause analysis reaches 97.83%, laying a theoretical foundation for building a strong distribution network.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
IET Smart Grid
IET Smart Grid Computer Science-Computer Networks and Communications
CiteScore
6.70
自引率
4.30%
发文量
41
审稿时长
29 weeks
期刊最新文献
Multi‐objective interval planning for 5G base station virtual power plants considering the consumption of photovoltaic and communication flexibility Probabilistic assessment of short‐term voltage stability under load and wind uncertainty Review on reliability assessment of energy storage systems Coordinated recovery of interdependent power and water distribution systems Incentivising peers in local transactive energy markets: A case study for consumers, prosumers and prosumagers
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1