不同精加工工艺对复合CAD/CAM材料表面粗糙度的影响

IF 0.2 Q4 DENTISTRY, ORAL SURGERY & MEDICINE Journal of Dentistry Indonesia Pub Date : 2021-12-30 DOI:10.14693/jdi.v28i3.1298
E. Akan, O. Colgecen, Ibrahim Talha Meşe, B. Bağış
{"title":"不同精加工工艺对复合CAD/CAM材料表面粗糙度的影响","authors":"E. Akan, O. Colgecen, Ibrahim Talha Meşe, B. Bağış","doi":"10.14693/jdi.v28i3.1298","DOIUrl":null,"url":null,"abstract":"Hybrid ceramics combine the beneficial properties of resin with the advantage of glass ceramics. However, there are limited study about on roughness properties of hybrid materials. Objective: To investigate of the effects of surface finishing methods on roughness of dental restorations made from hybrid CAD/CAM blocks. Methods: A total of 60 samples were produced (n=20) for three main material groups, two different hybrid ceramic (LAVA Ultimate and VITA Enamic) and a conventional glass ceramic (IPS e.max CAD). Each material group was divided into two subgroups (n=10). Ten samples were polished and 10 were glazed according to related manufacturer instructions. Surface roughness was measured with a surface profilometer. Data were statistically analysed using two-way ANOVA (p<0.05). Results: This study revealed that glazed surfaces were exhibited higher surface roughness values than polished surfaces in all materials (p<0.001). Minimum Ra values were belonged to Lava Ultimate polished group (Ra=0,07 μm) and maximum values were belonged to IPS e.max CAD glazed group (Ra=0,38 μm). Conclusion: Within the limitations of the present study, it may be suggested that finishing the hybrid ceramic restorations by mechanical polishing instead of glaze gives better clinical performance in regard to surface roughness.","PeriodicalId":53873,"journal":{"name":"Journal of Dentistry Indonesia","volume":" ","pages":""},"PeriodicalIF":0.2000,"publicationDate":"2021-12-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Effects of Different Finishing Procedures on Surface Roughness of Hybrid CAD/CAM Materials\",\"authors\":\"E. Akan, O. Colgecen, Ibrahim Talha Meşe, B. Bağış\",\"doi\":\"10.14693/jdi.v28i3.1298\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Hybrid ceramics combine the beneficial properties of resin with the advantage of glass ceramics. However, there are limited study about on roughness properties of hybrid materials. Objective: To investigate of the effects of surface finishing methods on roughness of dental restorations made from hybrid CAD/CAM blocks. Methods: A total of 60 samples were produced (n=20) for three main material groups, two different hybrid ceramic (LAVA Ultimate and VITA Enamic) and a conventional glass ceramic (IPS e.max CAD). Each material group was divided into two subgroups (n=10). Ten samples were polished and 10 were glazed according to related manufacturer instructions. Surface roughness was measured with a surface profilometer. Data were statistically analysed using two-way ANOVA (p<0.05). Results: This study revealed that glazed surfaces were exhibited higher surface roughness values than polished surfaces in all materials (p<0.001). Minimum Ra values were belonged to Lava Ultimate polished group (Ra=0,07 μm) and maximum values were belonged to IPS e.max CAD glazed group (Ra=0,38 μm). Conclusion: Within the limitations of the present study, it may be suggested that finishing the hybrid ceramic restorations by mechanical polishing instead of glaze gives better clinical performance in regard to surface roughness.\",\"PeriodicalId\":53873,\"journal\":{\"name\":\"Journal of Dentistry Indonesia\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.2000,\"publicationDate\":\"2021-12-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Dentistry Indonesia\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.14693/jdi.v28i3.1298\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Dentistry Indonesia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14693/jdi.v28i3.1298","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 1

摘要

混合陶瓷结合了树脂的有益性能和玻璃陶瓷的优点。然而,对杂化材料的粗糙度特性的研究还很有限。目的:探讨表面处理方法对复合CAD/CAM块修复体表面粗糙度的影响。方法:共制作了60个样品(n=20),用于三种主要材料组,两种不同的混合陶瓷(LAVA Ultimate和VITA Enamic)和一种传统玻璃陶瓷(IPS e.max CAD)。每个材料组被分为两个亚组(n=10)。根据相关制造商说明对10个样品进行抛光,并对10个进行上釉。使用表面轮廓仪测量表面粗糙度。使用双向方差分析对数据进行统计分析(p<0.05)。结果:本研究表明,在所有材料中,釉面表面的表面粗糙度值均高于抛光表面(p<0.001)。最小Ra值属于Lava Ultimate抛光组(Ra=0.07μm),最大Ra值属于IPS e.max CAD釉面组(Ra=0.38μm)。结论:在本研究的范围内,可以认为用机械抛光代替釉料抛光混合陶瓷修复体在表面粗糙度方面具有更好的临床性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Effects of Different Finishing Procedures on Surface Roughness of Hybrid CAD/CAM Materials
Hybrid ceramics combine the beneficial properties of resin with the advantage of glass ceramics. However, there are limited study about on roughness properties of hybrid materials. Objective: To investigate of the effects of surface finishing methods on roughness of dental restorations made from hybrid CAD/CAM blocks. Methods: A total of 60 samples were produced (n=20) for three main material groups, two different hybrid ceramic (LAVA Ultimate and VITA Enamic) and a conventional glass ceramic (IPS e.max CAD). Each material group was divided into two subgroups (n=10). Ten samples were polished and 10 were glazed according to related manufacturer instructions. Surface roughness was measured with a surface profilometer. Data were statistically analysed using two-way ANOVA (p<0.05). Results: This study revealed that glazed surfaces were exhibited higher surface roughness values than polished surfaces in all materials (p<0.001). Minimum Ra values were belonged to Lava Ultimate polished group (Ra=0,07 μm) and maximum values were belonged to IPS e.max CAD glazed group (Ra=0,38 μm). Conclusion: Within the limitations of the present study, it may be suggested that finishing the hybrid ceramic restorations by mechanical polishing instead of glaze gives better clinical performance in regard to surface roughness.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Dentistry Indonesia
Journal of Dentistry Indonesia DENTISTRY, ORAL SURGERY & MEDICINE-
自引率
0.00%
发文量
11
期刊最新文献
Factors Aff ors Affecting the Pr ecting the Preference of Or ence of Orthodontic Appliances thodontic Appliances Among Undergraduate Students in West Jakarta Evaluation of T aluation of Trabecular Bone Ar abecular Bone Around the Impacted Maxillar ound the Impacted Maxillary Canine on CBCT Images by Fractal Analysis Integration of Massive Open Online Course (MOOC) in Conventional Teaching and Learning for Fixed Prosthodontics - A Case Study Case Repor Case Report and X t and X-ray Microtomography and Scanning Electr aphy and Scanning Electron Microscopy Analysis of Teeth with Hypocalcified Amelogenesis Imperfecta Comparison of EDTA and Boric Acid Irrigation in Terms of Root Canal Dentin Microhardness and Sealer Penetration Depth
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1