{"title":"混合型无功功率补偿器,使控制系统的运行与电源电压参数相适应","authors":"S. Goolak, M. Kyrychenko, V. Tkachenko, Serhii Kozlov","doi":"10.52254/1857-0070.2023.1-57.01","DOIUrl":null,"url":null,"abstract":"The aim of the work is to develop a model of a hybrid reactive power compensator with adaptation of the control system to the parameters of the voltage supply. The task was achieved by applying the control algorithm for the operation of the control system of the active part of the reactive power compensator, which is based on the regression analysis method. The traction drive of the AC electric locomotive VL-80K, which is operated on the railways of the Ukraine, was chosen as the object of study. The simulation of the traction drive operation was carried out for a traction drive with and without a reactive power compensator, for cases where the process of changing the voltage in the catenary was a stationary deterministic process and for the case when this process was a nonstationary non-deterministic process. The most important result is the development of a block diagram of the control system for the active part of the reactive power compensator based on the implementation of the Levinson-Durbin linear prediction algorithm. The significance of the results obtained lies in the possibility of the proposed control scheme for the active part of the compensator to adapt the operation of the compensator to the voltage parameters of the catenary, that is, to the actual operating conditions of the electric locomotive.","PeriodicalId":41974,"journal":{"name":"Problemele Energeticii Regionale","volume":" ","pages":""},"PeriodicalIF":0.3000,"publicationDate":"2023-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Hybrid Reactive Power Compensator with Adaptation of the Operation of the Control System to the Parameters of the Mains Voltage\",\"authors\":\"S. Goolak, M. Kyrychenko, V. Tkachenko, Serhii Kozlov\",\"doi\":\"10.52254/1857-0070.2023.1-57.01\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The aim of the work is to develop a model of a hybrid reactive power compensator with adaptation of the control system to the parameters of the voltage supply. The task was achieved by applying the control algorithm for the operation of the control system of the active part of the reactive power compensator, which is based on the regression analysis method. The traction drive of the AC electric locomotive VL-80K, which is operated on the railways of the Ukraine, was chosen as the object of study. The simulation of the traction drive operation was carried out for a traction drive with and without a reactive power compensator, for cases where the process of changing the voltage in the catenary was a stationary deterministic process and for the case when this process was a nonstationary non-deterministic process. The most important result is the development of a block diagram of the control system for the active part of the reactive power compensator based on the implementation of the Levinson-Durbin linear prediction algorithm. The significance of the results obtained lies in the possibility of the proposed control scheme for the active part of the compensator to adapt the operation of the compensator to the voltage parameters of the catenary, that is, to the actual operating conditions of the electric locomotive.\",\"PeriodicalId\":41974,\"journal\":{\"name\":\"Problemele Energeticii Regionale\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.3000,\"publicationDate\":\"2023-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Problemele Energeticii Regionale\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.52254/1857-0070.2023.1-57.01\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENERGY & FUELS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Problemele Energeticii Regionale","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.52254/1857-0070.2023.1-57.01","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
引用次数: 1

摘要

本文的目的是建立一种混合无功补偿器模型,该模型具有控制系统对电源参数的自适应能力。将基于回归分析方法的无功补偿器有功部分控制系统的运行控制算法应用于无功补偿器有功部分控制系统的运行。选取在乌克兰铁路上运行的交流电力机车VL-80K的牵引传动作为研究对象。针对接触网电压变化过程为平稳确定性过程和非平稳非确定性过程,分别对带无功补偿器和不带无功补偿器的牵引传动进行了运行仿真。最重要的结果是基于Levinson-Durbin线性预测算法的实现,开发了无功补偿器有功部分控制系统的框图。所得结果的意义在于所提出的补偿器主动部分的控制方案能够使补偿器的运行适应接触网的电压参数,即适应电力机车的实际运行条件。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Hybrid Reactive Power Compensator with Adaptation of the Operation of the Control System to the Parameters of the Mains Voltage
The aim of the work is to develop a model of a hybrid reactive power compensator with adaptation of the control system to the parameters of the voltage supply. The task was achieved by applying the control algorithm for the operation of the control system of the active part of the reactive power compensator, which is based on the regression analysis method. The traction drive of the AC electric locomotive VL-80K, which is operated on the railways of the Ukraine, was chosen as the object of study. The simulation of the traction drive operation was carried out for a traction drive with and without a reactive power compensator, for cases where the process of changing the voltage in the catenary was a stationary deterministic process and for the case when this process was a nonstationary non-deterministic process. The most important result is the development of a block diagram of the control system for the active part of the reactive power compensator based on the implementation of the Levinson-Durbin linear prediction algorithm. The significance of the results obtained lies in the possibility of the proposed control scheme for the active part of the compensator to adapt the operation of the compensator to the voltage parameters of the catenary, that is, to the actual operating conditions of the electric locomotive.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
0.70
自引率
33.30%
发文量
38
期刊最新文献
Reduction of Voltage Fluctuations in Electrical Networks Supplying Motors with a Rapidly Changing Load by Installing Longitudinal Compensation Batteries Intelligent System of Relay Protection of Electrical Network 6-10 kV with the Implementation of Automatic Correction of the Operation Set Point Energy-Efficient Modes of Dehydration of Pome Fruits during Microwave Treatment in Combination with Convection Congestion Management Using an Optimized Deep Convolution Neural Network in Deregulated Environment Study of the Efficiency of Heat-Supply Systems with Steam Turbine CHP Plants, Taking into Account Changes in the Temperature of the Delivery Water during Transportation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1