印度尼西亚对合成废水电解电导率测量的熟练程度测试:基于四种标准化性能统计的性能评估的比较

IF 0.8 4区 工程技术 Q4 CHEMISTRY, ANALYTICAL Accreditation and Quality Assurance Pub Date : 2023-01-18 DOI:10.1007/s00769-022-01526-7
Fransiska Sri Herwahyu Krismastuti, Nuryatini Hamim, Ayu Hindayani
{"title":"印度尼西亚对合成废水电解电导率测量的熟练程度测试:基于四种标准化性能统计的性能评估的比较","authors":"Fransiska Sri Herwahyu Krismastuti,&nbsp;Nuryatini Hamim,&nbsp;Ayu Hindayani","doi":"10.1007/s00769-022-01526-7","DOIUrl":null,"url":null,"abstract":"<div><p>Electrolytic conductivity is recognized as one of the parameters to determine water quality. An accurate measurement of electrolytic conductivity of wastewater before dumping it into the environment is crucial to prevent water pollution. Therefore, the ability of laboratories in conducting accurate and comparable measurements of electrolytic conductivity is important to guarantee the measurement results. The measurement quality of the laboratories can be determined by participating in a proficiency testing (PT) conducted by accredited PT provider. In 2018, Chemical Metrology Laboratory, Indonesian Institute of Sciences (LIPI), as a PT provider, conducted a PT for electrolytic conductivity measurement with synthetic wastewater as the PT test item. It was prepared from cations and anions commonly found in natural wastewater. A total of 25 participants from Indonesian testing laboratories reported their electrolytic conductivity measurements. These results were then evaluated using a standardized performance statistic of <i>z</i> score, <i>z</i>′ score, <i>E</i><sub>n</sub> score and ζ (zeta) score. There were 20 laboratories having satisfactory results evaluated using both <i>z</i> score and <i>z</i>′ score, while only 14 laboratories were considered having a successful performance evaluated using <i>E</i><sub>n</sub> score and ζ score. The evaluation results show that the participants already have the ability to measure the electrolytic conductivity value but some of them still need improvement in estimating the uncertainty.\n</p></div>","PeriodicalId":454,"journal":{"name":"Accreditation and Quality Assurance","volume":"28 1","pages":"1 - 9"},"PeriodicalIF":0.8000,"publicationDate":"2023-01-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://link.springer.com/content/pdf/10.1007/s00769-022-01526-7.pdf","citationCount":"0","resultStr":"{\"title\":\"Indonesian proficiency testing for electrolytic conductivity measurement of synthetic wastewater: a comparison of performance evaluation based on four standardized performance statistics\",\"authors\":\"Fransiska Sri Herwahyu Krismastuti,&nbsp;Nuryatini Hamim,&nbsp;Ayu Hindayani\",\"doi\":\"10.1007/s00769-022-01526-7\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Electrolytic conductivity is recognized as one of the parameters to determine water quality. An accurate measurement of electrolytic conductivity of wastewater before dumping it into the environment is crucial to prevent water pollution. Therefore, the ability of laboratories in conducting accurate and comparable measurements of electrolytic conductivity is important to guarantee the measurement results. The measurement quality of the laboratories can be determined by participating in a proficiency testing (PT) conducted by accredited PT provider. In 2018, Chemical Metrology Laboratory, Indonesian Institute of Sciences (LIPI), as a PT provider, conducted a PT for electrolytic conductivity measurement with synthetic wastewater as the PT test item. It was prepared from cations and anions commonly found in natural wastewater. A total of 25 participants from Indonesian testing laboratories reported their electrolytic conductivity measurements. These results were then evaluated using a standardized performance statistic of <i>z</i> score, <i>z</i>′ score, <i>E</i><sub>n</sub> score and ζ (zeta) score. There were 20 laboratories having satisfactory results evaluated using both <i>z</i> score and <i>z</i>′ score, while only 14 laboratories were considered having a successful performance evaluated using <i>E</i><sub>n</sub> score and ζ score. The evaluation results show that the participants already have the ability to measure the electrolytic conductivity value but some of them still need improvement in estimating the uncertainty.\\n</p></div>\",\"PeriodicalId\":454,\"journal\":{\"name\":\"Accreditation and Quality Assurance\",\"volume\":\"28 1\",\"pages\":\"1 - 9\"},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2023-01-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://link.springer.com/content/pdf/10.1007/s00769-022-01526-7.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accreditation and Quality Assurance\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://link.springer.com/article/10.1007/s00769-022-01526-7\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accreditation and Quality Assurance","FirstCategoryId":"5","ListUrlMain":"https://link.springer.com/article/10.1007/s00769-022-01526-7","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

电解电导率是公认的决定水质的参数之一。在将废水排入环境之前准确测量其电解电导率对防止水污染至关重要。因此,实验室进行准确和可比较的电解电导率测量的能力对于保证测量结果非常重要。实验室的测量质量可以通过参加由认可的测试机构进行的能力测试(PT)来确定。2018年,印度尼西亚科学研究所(LIPI)化学计量实验室作为PT提供商,以合成废水为PT测试项目,进行了电解电导率测量的PT。它是由天然废水中常见的阳离子和阴离子制备的。共有25名来自印度尼西亚测试实验室的参与者报告了他们的电解电导率测量结果。然后使用z分数,z '分数,En分数和ζ (zeta)分数的标准化性能统计对这些结果进行评估。有20个实验室使用z分数和z '分数进行了满意的评估,而只有14个实验室使用En分数和ζ分数进行了成功的评估。评估结果表明,参与者已经具备了测量电解电导率值的能力,但有些参与者在不确定度的估计方面仍有待改进。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Indonesian proficiency testing for electrolytic conductivity measurement of synthetic wastewater: a comparison of performance evaluation based on four standardized performance statistics

Electrolytic conductivity is recognized as one of the parameters to determine water quality. An accurate measurement of electrolytic conductivity of wastewater before dumping it into the environment is crucial to prevent water pollution. Therefore, the ability of laboratories in conducting accurate and comparable measurements of electrolytic conductivity is important to guarantee the measurement results. The measurement quality of the laboratories can be determined by participating in a proficiency testing (PT) conducted by accredited PT provider. In 2018, Chemical Metrology Laboratory, Indonesian Institute of Sciences (LIPI), as a PT provider, conducted a PT for electrolytic conductivity measurement with synthetic wastewater as the PT test item. It was prepared from cations and anions commonly found in natural wastewater. A total of 25 participants from Indonesian testing laboratories reported their electrolytic conductivity measurements. These results were then evaluated using a standardized performance statistic of z score, z′ score, En score and ζ (zeta) score. There were 20 laboratories having satisfactory results evaluated using both z score and z′ score, while only 14 laboratories were considered having a successful performance evaluated using En score and ζ score. The evaluation results show that the participants already have the ability to measure the electrolytic conductivity value but some of them still need improvement in estimating the uncertainty.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Accreditation and Quality Assurance
Accreditation and Quality Assurance 工程技术-分析化学
CiteScore
1.80
自引率
22.20%
发文量
39
审稿时长
6-12 weeks
期刊介绍: Accreditation and Quality Assurance has established itself as the leading information and discussion forum for all aspects relevant to quality, transparency and reliability of measurement results in chemical and biological sciences. The journal serves the information needs of researchers, practitioners and decision makers dealing with quality assurance and quality management, including the development and application of metrological principles and concepts such as traceability or measurement uncertainty in the following fields: environment, nutrition, consumer protection, geology, metallurgy, pharmacy, forensics, clinical chemistry and laboratory medicine, and microbiology.
期刊最新文献
Correction: Certification of the total element mass fractions in UME EnvCRM 03 soil sample via a joint research project Association between blood lead levels and socio-demographic factors among outpatient children in Ningbo, China Proficiency tests for analysis of pesticide residues in kimchi cabbage and ginseng in South Korea from 2008 to 2020 Points to consider when establishing an equipment calibration programme in a conventional food microbiology laboratory for ISO/IEC 17025:2017 accreditation purpose Approaches for the production of reference materials with qualitative properties—The new International Standard ISO 33406
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1