使用可穿戴传感器和坐立测试评估平衡、认知功能和跌倒风险

IF 3.4 Q2 ENGINEERING, BIOMEDICAL Wearable technologies Pub Date : 2022-06-07 eCollection Date: 2022-01-01 DOI:10.1017/wtc.2022.6
Barry R Greene, Emer P Doheny, Killian McManus, Brian Caulfield
{"title":"使用可穿戴传感器和坐立测试评估平衡、认知功能和跌倒风险","authors":"Barry R Greene, Emer P Doheny, Killian McManus, Brian Caulfield","doi":"10.1017/wtc.2022.6","DOIUrl":null,"url":null,"abstract":"<p><p>The five times sit-to-stand test (FTSS) is an established functional test, used clinically as a measure of lower-limb strength, endurance and falls risk. We report a novel method to estimate and classify cognitive function, balance impairment and falls risk using the FTSS and body-worn inertial sensors. 168 community dwelling older adults received a Comprehensive Geriatric Assessment which included the Mini-Mental State Examination (MMSE) and the Berg Balance Scale (BBS). Each participant performed an FTSS, with inertial sensors on the thigh and torso, either at home or in the clinical environment. Adaptive peak detection was used to identify phases of each FTSS from torso or thigh-mounted inertial sensors. Features were then extracted from each sensor to quantify the timing, postural sway and variability of each FTSS. The relationship between each feature and MMSE and BBS was examined using Spearman's correlation. Intraclass correlation coefficients were used to examine the intra-session reliability of each feature. A Poisson regression model with an elastic net model selection procedure was used to estimate MMSE and BBS scores, while logistic regression and sequential forward feature selection was used to classify participants according to falls risk, cognitive decline and balance impairment. BBS and MMSE were estimated using cross-validation with low root mean squared errors of 2.91 and 1.50, respectively, while the cross-validated classification accuracies for balance impairment, cognitive decline, and falls risk were 81.96, 72.71, and 68.74%, respectively. The novel methods reported provide surrogate measures which may have utility in remote assessment of physical and cognitive function.</p>","PeriodicalId":75318,"journal":{"name":"Wearable technologies","volume":null,"pages":null},"PeriodicalIF":3.4000,"publicationDate":"2022-06-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10936403/pdf/","citationCount":"0","resultStr":"{\"title\":\"Estimating balance, cognitive function, and falls risk using wearable sensors and the sit-to-stand test.\",\"authors\":\"Barry R Greene, Emer P Doheny, Killian McManus, Brian Caulfield\",\"doi\":\"10.1017/wtc.2022.6\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The five times sit-to-stand test (FTSS) is an established functional test, used clinically as a measure of lower-limb strength, endurance and falls risk. We report a novel method to estimate and classify cognitive function, balance impairment and falls risk using the FTSS and body-worn inertial sensors. 168 community dwelling older adults received a Comprehensive Geriatric Assessment which included the Mini-Mental State Examination (MMSE) and the Berg Balance Scale (BBS). Each participant performed an FTSS, with inertial sensors on the thigh and torso, either at home or in the clinical environment. Adaptive peak detection was used to identify phases of each FTSS from torso or thigh-mounted inertial sensors. Features were then extracted from each sensor to quantify the timing, postural sway and variability of each FTSS. The relationship between each feature and MMSE and BBS was examined using Spearman's correlation. Intraclass correlation coefficients were used to examine the intra-session reliability of each feature. A Poisson regression model with an elastic net model selection procedure was used to estimate MMSE and BBS scores, while logistic regression and sequential forward feature selection was used to classify participants according to falls risk, cognitive decline and balance impairment. BBS and MMSE were estimated using cross-validation with low root mean squared errors of 2.91 and 1.50, respectively, while the cross-validated classification accuracies for balance impairment, cognitive decline, and falls risk were 81.96, 72.71, and 68.74%, respectively. The novel methods reported provide surrogate measures which may have utility in remote assessment of physical and cognitive function.</p>\",\"PeriodicalId\":75318,\"journal\":{\"name\":\"Wearable technologies\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.4000,\"publicationDate\":\"2022-06-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10936403/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Wearable technologies\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1017/wtc.2022.6\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2022/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Wearable technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1017/wtc.2022.6","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

摘要五次坐立试验(FTSS)是一种已建立的功能性试验,临床上用于测量下肢力量、耐力和跌倒风险。我们报告了一种使用FTSS和随身携带的惯性传感器来估计和分类认知功能、平衡障碍和跌倒风险的新方法。168名居住在社区的老年人接受了综合老年评估,其中包括迷你精神状态检查(MMSE)和伯格平衡量表(BBS)。每个参与者都在家里或临床环境中使用大腿和躯干上的惯性传感器进行FTSS。自适应峰值检测用于从躯干或大腿安装的惯性传感器识别每个FTSS的相位。然后从每个传感器中提取特征,以量化每个FTSS的时间、姿势摆动和可变性。使用Spearman相关性检验每个特征与MMSE和BBS之间的关系。组内相关系数用于检查每个特征的会话内可靠性。采用Poisson回归模型和弹性网络模型选择程序来估计MMSE和BBS得分,而采用逻辑回归和序列前向特征选择来根据跌倒风险、认知能力下降和平衡障碍对参与者进行分类。BBS和MMSE使用交叉验证进行估计,低均方根误差分别为2.91和1.50,而平衡障碍、认知能力下降和跌倒风险的交叉验证分类准确率分别为81.96%、72.71%和68.74%。报告的新方法提供了替代措施,可能在身体和认知功能的远程评估中有用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Estimating balance, cognitive function, and falls risk using wearable sensors and the sit-to-stand test.

The five times sit-to-stand test (FTSS) is an established functional test, used clinically as a measure of lower-limb strength, endurance and falls risk. We report a novel method to estimate and classify cognitive function, balance impairment and falls risk using the FTSS and body-worn inertial sensors. 168 community dwelling older adults received a Comprehensive Geriatric Assessment which included the Mini-Mental State Examination (MMSE) and the Berg Balance Scale (BBS). Each participant performed an FTSS, with inertial sensors on the thigh and torso, either at home or in the clinical environment. Adaptive peak detection was used to identify phases of each FTSS from torso or thigh-mounted inertial sensors. Features were then extracted from each sensor to quantify the timing, postural sway and variability of each FTSS. The relationship between each feature and MMSE and BBS was examined using Spearman's correlation. Intraclass correlation coefficients were used to examine the intra-session reliability of each feature. A Poisson regression model with an elastic net model selection procedure was used to estimate MMSE and BBS scores, while logistic regression and sequential forward feature selection was used to classify participants according to falls risk, cognitive decline and balance impairment. BBS and MMSE were estimated using cross-validation with low root mean squared errors of 2.91 and 1.50, respectively, while the cross-validated classification accuracies for balance impairment, cognitive decline, and falls risk were 81.96, 72.71, and 68.74%, respectively. The novel methods reported provide surrogate measures which may have utility in remote assessment of physical and cognitive function.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
5.80
自引率
0.00%
发文量
0
审稿时长
11 weeks
期刊最新文献
Concurrent validity of inertial measurement units in range of motion measurements of upper extremity: A systematic review and meta-analysis. Acute suppression of lower limb spasm by sacral afferent stimulation for people with spinal cord injury: A pilot study GLULA: Linear attention-based model for efficient human activity recognition from wearable sensors Erratum: Validity of estimating center of pressure during walking and running with plantar load from a three-sensor wireless insole - ERRATUM. A novel neck brace to characterize neck mobility impairments following neck dissection in head and neck cancer patients - ADDENDUM.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1