成人使用Airtraq™视频喉镜进行面对面气管插管和传统头端气管插管的比较——一项随机研究

IF 1.5 Q3 PHARMACOLOGY & PHARMACY Journal of Anaesthesiology, Clinical Pharmacology Pub Date : 2023-10-01 Epub Date: 2023-05-22 DOI:10.4103/joacp.joacp_161_22
Swati Bharti, Sujata Chaudhary, Rashmi Salhotra, Seema Meena
{"title":"成人使用Airtraq™视频喉镜进行面对面气管插管和传统头端气管插管的比较——一项随机研究","authors":"Swati Bharti, Sujata Chaudhary, Rashmi Salhotra, Seema Meena","doi":"10.4103/joacp.joacp_161_22","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and aims: </strong>Tracheal intubation can be difficult in certain scenarios where the head-end of the patient is not accessible as in entrapped casualties. A face-to-face technique using a video-laryngoscope can prove to be useful in such scenarios. However, the two positions of tracheal intubation namely, face-to-face and head-end, using video-laryngoscope have never been compared in patients.</p><p><strong>Material and methods: </strong>Fifty patients of either sex, between 18 and 60 years, ASA class I/II, MPC I/II, scheduled to undergo surgical operations requiring general anesthesia with tracheal intubation were randomly allocated to either Group F (face-to-face intubation) or Group H (head-end intubation). Intubation was performed using Airtraq™ video-laryngoscope in both groups. Time taken for successful intubation, device insertion time, glottic view as per Cormack and Lehane (CL) grade, ease, attempts, the incidence of failed intubation, and hemodynamic parameters were noted.</p><p><strong>Results: </strong>The time taken for successful intubation in Group F was significantly longer than in Group H (38.09 ± 19.45 s vs. 19.32 ± 9.86 s, respectively; <i>P</i> < 0.001). Three cases of failed intubation were noted in Group F compared to none in Group H (<i>P</i> = 0.235). Glottic view, ease, attempts, and hemodynamic parameters were comparable among the groups (<i>P</i> > 0.05).</p><p><strong>Conclusion: </strong>The time taken for successful tracheal intubation was longer in face-to-face technique than in head-end technique in patients with the normal airway. However, both techniques were similar in terms of glottic view, ease of intubation and number of intubation attempts, the incidence of failed intubation, and hemodynamic changes. Therefore, face-to-face tracheal intubation is a good alternative to secure the airway when the head-end is not accessible.</p>","PeriodicalId":14946,"journal":{"name":"Journal of Anaesthesiology, Clinical Pharmacology","volume":null,"pages":null},"PeriodicalIF":1.5000,"publicationDate":"2023-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10805199/pdf/","citationCount":"0","resultStr":"{\"title\":\"Comparison of face-to-face tracheal intubation and conventional head-end tracheal intubation using Airtraq™ video-laryngoscope in adults - A randomised study.\",\"authors\":\"Swati Bharti, Sujata Chaudhary, Rashmi Salhotra, Seema Meena\",\"doi\":\"10.4103/joacp.joacp_161_22\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background and aims: </strong>Tracheal intubation can be difficult in certain scenarios where the head-end of the patient is not accessible as in entrapped casualties. A face-to-face technique using a video-laryngoscope can prove to be useful in such scenarios. However, the two positions of tracheal intubation namely, face-to-face and head-end, using video-laryngoscope have never been compared in patients.</p><p><strong>Material and methods: </strong>Fifty patients of either sex, between 18 and 60 years, ASA class I/II, MPC I/II, scheduled to undergo surgical operations requiring general anesthesia with tracheal intubation were randomly allocated to either Group F (face-to-face intubation) or Group H (head-end intubation). Intubation was performed using Airtraq™ video-laryngoscope in both groups. Time taken for successful intubation, device insertion time, glottic view as per Cormack and Lehane (CL) grade, ease, attempts, the incidence of failed intubation, and hemodynamic parameters were noted.</p><p><strong>Results: </strong>The time taken for successful intubation in Group F was significantly longer than in Group H (38.09 ± 19.45 s vs. 19.32 ± 9.86 s, respectively; <i>P</i> < 0.001). Three cases of failed intubation were noted in Group F compared to none in Group H (<i>P</i> = 0.235). Glottic view, ease, attempts, and hemodynamic parameters were comparable among the groups (<i>P</i> > 0.05).</p><p><strong>Conclusion: </strong>The time taken for successful tracheal intubation was longer in face-to-face technique than in head-end technique in patients with the normal airway. However, both techniques were similar in terms of glottic view, ease of intubation and number of intubation attempts, the incidence of failed intubation, and hemodynamic changes. Therefore, face-to-face tracheal intubation is a good alternative to secure the airway when the head-end is not accessible.</p>\",\"PeriodicalId\":14946,\"journal\":{\"name\":\"Journal of Anaesthesiology, Clinical Pharmacology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2023-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10805199/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Anaesthesiology, Clinical Pharmacology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/joacp.joacp_161_22\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/5/22 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"PHARMACOLOGY & PHARMACY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Anaesthesiology, Clinical Pharmacology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/joacp.joacp_161_22","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/5/22 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"PHARMACOLOGY & PHARMACY","Score":null,"Total":0}
引用次数: 0

摘要

背景和目的:在某些情况下,气管插管可能比较困难,因为病人的头端无法接近,比如被困的伤员。在这种情况下,使用视频喉镜的面对面插管技术证明是有用的。然而,使用视频喉镜进行气管插管的两种姿势,即面对面插管和头端插管,从未在患者身上进行过比较:将 50 名性别不限、年龄在 18 至 60 岁之间、ASA I/II 级、MPC I/II 级、计划接受需要气管插管全身麻醉的外科手术的患者随机分配到 F 组(面对面插管)或 H 组(头端插管)。两组均使用 Airtraq™ 视频喉镜进行插管。记录插管成功所用时间、设备插入时间、Cormack 和 Lehane(CL)分级的声门视野、难易程度、尝试次数、插管失败发生率以及血液动力学参数:结果:F 组成功插管的时间明显长于 H 组(分别为 38.09±19.45 秒和 19.32±9.86 秒;P <0.001)。F 组有三例插管失败,而 H 组没有(P = 0.235)。各组的声门视野、难易程度、尝试次数和血液动力学参数相当(P > 0.05):结论:在气道正常的患者中,面对面插管技术比头端插管技术成功所需的时间更长。然而,就声门视野、插管难易度和插管尝试次数、插管失败发生率以及血流动力学变化而言,两种技术相似。因此,在头端无法进入的情况下,面对面气管插管是确保气道安全的良好选择。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Comparison of face-to-face tracheal intubation and conventional head-end tracheal intubation using Airtraq™ video-laryngoscope in adults - A randomised study.

Background and aims: Tracheal intubation can be difficult in certain scenarios where the head-end of the patient is not accessible as in entrapped casualties. A face-to-face technique using a video-laryngoscope can prove to be useful in such scenarios. However, the two positions of tracheal intubation namely, face-to-face and head-end, using video-laryngoscope have never been compared in patients.

Material and methods: Fifty patients of either sex, between 18 and 60 years, ASA class I/II, MPC I/II, scheduled to undergo surgical operations requiring general anesthesia with tracheal intubation were randomly allocated to either Group F (face-to-face intubation) or Group H (head-end intubation). Intubation was performed using Airtraq™ video-laryngoscope in both groups. Time taken for successful intubation, device insertion time, glottic view as per Cormack and Lehane (CL) grade, ease, attempts, the incidence of failed intubation, and hemodynamic parameters were noted.

Results: The time taken for successful intubation in Group F was significantly longer than in Group H (38.09 ± 19.45 s vs. 19.32 ± 9.86 s, respectively; P < 0.001). Three cases of failed intubation were noted in Group F compared to none in Group H (P = 0.235). Glottic view, ease, attempts, and hemodynamic parameters were comparable among the groups (P > 0.05).

Conclusion: The time taken for successful tracheal intubation was longer in face-to-face technique than in head-end technique in patients with the normal airway. However, both techniques were similar in terms of glottic view, ease of intubation and number of intubation attempts, the incidence of failed intubation, and hemodynamic changes. Therefore, face-to-face tracheal intubation is a good alternative to secure the airway when the head-end is not accessible.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.90
自引率
6.70%
发文量
129
期刊介绍: The JOACP publishes original peer-reviewed research and clinical work in all branches of anaesthesiology, pain, critical care and perioperative medicine including the application to basic sciences. In addition, the journal publishes review articles, special articles, brief communications/reports, case reports, and reports of new equipment, letters to editor, book reviews and obituaries. It is international in scope and comprehensive in coverage.
期刊最新文献
Assessment of the application of double-modified nasopharyngeal airways versus the use of low-flow nasal cannula during pediatric upper gastrointestinal endoscopy: A prospective, randomized, noninferiority, controlled trial. Effects of propofol-based total intravenous anesthesia versus desflurane anesthesia on natural killer cell cytotoxicity after hepatocellular carcinoma resection. A double-blinded randomized control trial to compare the duration of analgesia using morphine, clonidine, or dexmedetomidine as adjuvants to ropivacaine in caudal anesthesia in children undergoing infraumbilical surgeries. Target-controlled infusion - Past, present, and future. Assessment of preparedness for emergency cesarean section by utilizing a checklist before and after an educational intervention: A quality improvement study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1