不同颜色软性隐形眼镜对泪液质量和眼表特性的影响

IF 6.7 3区 工程技术 Q1 ENGINEERING, ELECTRICAL & ELECTRONIC International Journal of Optomechatronics Pub Date : 2021-01-01 DOI:10.1080/15599612.2021.1892247
Min-Yen Hsu, Yu-Ping Wang, Pei-Yu Hong, Pei-Ying Chen, Connie Chen
{"title":"不同颜色软性隐形眼镜对泪液质量和眼表特性的影响","authors":"Min-Yen Hsu, Yu-Ping Wang, Pei-Yu Hong, Pei-Ying Chen, Connie Chen","doi":"10.1080/15599612.2021.1892247","DOIUrl":null,"url":null,"abstract":"Abstract Different designs for contact lenses can result in insufficient oxygen permeability of the lenses. Moreover, the contact lens wearing schedule, replacement, lens care systems, and purchase methods are all important considerations for contact lens wearers. To evaluate the influence of tinted contact lenses with the pigment layer in different locations on the tear quality and ocular surface properties, as well as the subjective experience of the wearer In this randomized double-blind study, 30 healthy subjects (60 eyes) were randomly assigned to two groups. The pigment layer of lenses in group I was embedded within the matrix, close to the front surface, while that in group II was located on the front surface of the lens. Subjects wore the contact lenses for 7 days, 8 h a day. In both groups, the frequency of blinking after lens wear increased significantly relative to that before lens wear. The tear-breakup time was significantly shorter in group II than in group I. Temporal bulbar conjunctiva, nasal bulbar conjunctiva, temporal limbal, nasal limbal, and eyelid redness levels in both groups, and corneal staining levels in group II, were significantly increased after 7-day lens wear. Nasal bulbar conjunctiva, temporal limbal, and nasal limbal redness; eyelid smoothness; and corneal staining levels were significantly higher in group II. There was no significant between-group difference in the subjective experience. Ocular surface properties deteriorated while the frequency of blinking increased after wear of both types of tinted contact lenses for 7 days. Both designs resulted in insufficient oxygen permeability of the contact lenses.","PeriodicalId":50296,"journal":{"name":"International Journal of Optomechatronics","volume":"15 1","pages":"10 - 18"},"PeriodicalIF":6.7000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/15599612.2021.1892247","citationCount":"0","resultStr":"{\"title\":\"Effect of different tinted soft contact lenses on the tear quality and ocular surface properties\",\"authors\":\"Min-Yen Hsu, Yu-Ping Wang, Pei-Yu Hong, Pei-Ying Chen, Connie Chen\",\"doi\":\"10.1080/15599612.2021.1892247\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract Different designs for contact lenses can result in insufficient oxygen permeability of the lenses. Moreover, the contact lens wearing schedule, replacement, lens care systems, and purchase methods are all important considerations for contact lens wearers. To evaluate the influence of tinted contact lenses with the pigment layer in different locations on the tear quality and ocular surface properties, as well as the subjective experience of the wearer In this randomized double-blind study, 30 healthy subjects (60 eyes) were randomly assigned to two groups. The pigment layer of lenses in group I was embedded within the matrix, close to the front surface, while that in group II was located on the front surface of the lens. Subjects wore the contact lenses for 7 days, 8 h a day. In both groups, the frequency of blinking after lens wear increased significantly relative to that before lens wear. The tear-breakup time was significantly shorter in group II than in group I. Temporal bulbar conjunctiva, nasal bulbar conjunctiva, temporal limbal, nasal limbal, and eyelid redness levels in both groups, and corneal staining levels in group II, were significantly increased after 7-day lens wear. Nasal bulbar conjunctiva, temporal limbal, and nasal limbal redness; eyelid smoothness; and corneal staining levels were significantly higher in group II. There was no significant between-group difference in the subjective experience. Ocular surface properties deteriorated while the frequency of blinking increased after wear of both types of tinted contact lenses for 7 days. Both designs resulted in insufficient oxygen permeability of the contact lenses.\",\"PeriodicalId\":50296,\"journal\":{\"name\":\"International Journal of Optomechatronics\",\"volume\":\"15 1\",\"pages\":\"10 - 18\"},\"PeriodicalIF\":6.7000,\"publicationDate\":\"2021-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1080/15599612.2021.1892247\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Optomechatronics\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1080/15599612.2021.1892247\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Optomechatronics","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1080/15599612.2021.1892247","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

摘要

隐形眼镜的不同设计可能导致隐形眼镜的透氧性不足。此外,隐形眼镜佩戴时间表、更换、镜片护理系统和购买方法都是隐形眼镜佩戴者的重要考虑因素。为了评估色素层位于不同位置的有色隐形眼镜对泪液质量和眼表特性的影响,以及佩戴者的主观体验。在这项随机双盲研究中,30名健康受试者(60只眼睛)被随机分为两组。第一组镜片的色素层嵌入基质中,靠近前表面,而第二组镜片的颜料层位于镜片的前表面。受试者佩戴隐形眼镜7天 天,8 h一天。在两组中,佩戴镜片后的眨眼频率都比佩戴镜片前显著增加。第二组的撕裂时间明显短于第一组。两组的颞球结膜、鼻球结膜、颞缘、鼻缘和眼睑发红程度以及第二组角膜染色程度在佩戴7天后显著增加。鼻球结膜、颞缘和鼻缘发红;眼睑平滑度;并且角膜染色水平在组II中显著较高。在主观体验方面,组间无显著差异。佩戴两种类型的有色隐形眼镜7天后,眼睛表面性质恶化,眨眼频率增加 天。两种设计都导致隐形眼镜的透氧性不足。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Effect of different tinted soft contact lenses on the tear quality and ocular surface properties
Abstract Different designs for contact lenses can result in insufficient oxygen permeability of the lenses. Moreover, the contact lens wearing schedule, replacement, lens care systems, and purchase methods are all important considerations for contact lens wearers. To evaluate the influence of tinted contact lenses with the pigment layer in different locations on the tear quality and ocular surface properties, as well as the subjective experience of the wearer In this randomized double-blind study, 30 healthy subjects (60 eyes) were randomly assigned to two groups. The pigment layer of lenses in group I was embedded within the matrix, close to the front surface, while that in group II was located on the front surface of the lens. Subjects wore the contact lenses for 7 days, 8 h a day. In both groups, the frequency of blinking after lens wear increased significantly relative to that before lens wear. The tear-breakup time was significantly shorter in group II than in group I. Temporal bulbar conjunctiva, nasal bulbar conjunctiva, temporal limbal, nasal limbal, and eyelid redness levels in both groups, and corneal staining levels in group II, were significantly increased after 7-day lens wear. Nasal bulbar conjunctiva, temporal limbal, and nasal limbal redness; eyelid smoothness; and corneal staining levels were significantly higher in group II. There was no significant between-group difference in the subjective experience. Ocular surface properties deteriorated while the frequency of blinking increased after wear of both types of tinted contact lenses for 7 days. Both designs resulted in insufficient oxygen permeability of the contact lenses.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
International Journal of Optomechatronics
International Journal of Optomechatronics 工程技术-工程:电子与电气
CiteScore
9.30
自引率
0.00%
发文量
3
审稿时长
3 months
期刊介绍: International Journal of Optomechatronics publishes the latest results of multidisciplinary research at the crossroads between optics, mechanics, fluidics and electronics. Topics you can submit include, but are not limited to: -Adaptive optics- Optomechanics- Machine vision, tracking and control- Image-based micro-/nano- manipulation- Control engineering for optomechatronics- Optical metrology- Optical sensors and light-based actuators- Optomechatronics for astronomy and space applications- Optical-based inspection and fault diagnosis- Micro-/nano- optomechanical systems (MOEMS)- Optofluidics- Optical assembly and packaging- Optical and vision-based manufacturing, processes, monitoring, and control- Optomechatronics systems in bio- and medical technologies (such as optical coherence tomography (OCT) systems or endoscopes and optical based medical instruments)
期刊最新文献
Laboratory demonstration of single-camera PPPP wavefront sensing using neural networks Control of a quasi-static MEMS Mirror for raster scanning projection applications Resonator-based near perfect metamaterial absorber with high EMI shielding for Wi-Fi and 5G applications Optofluidic sorting of microparticles using Airy beams Review of sensing and actuation technologies – from optical MEMS and nanophotonics to photonic nanosystems
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1