{"title":"基于游标效应修正灵敏度的应变光纤传感器","authors":"D. Jáuregui-Vázquez, J. Korterik, H. Offerhaus, R. Rojas‐Laguna, J. Álvarez-Chávez","doi":"10.1080/10739149.2022.2150005","DOIUrl":null,"url":null,"abstract":"Abstract An optical fiber strain sensor with adjustable sensitivity is proposed and demonstrated. The strain sensing setup employs a fiber optic Michelson interferometer (sensing element) and an extrinsic Fabry–Perot interferometer, in which both structures excited the Vernier effect. By adjusting the cavity length of the extrinsic Fabry–Perot interferometer, it is possible to control the M-factor. The set-up offers both sensitivity enhancement and magnification mode, where the maximal sensitivity is 4.38 pm/με (M-factor = 2.3). This design improves the sensor performance and its implementation is not intricate.","PeriodicalId":13547,"journal":{"name":"Instrumentation Science & Technology","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2022-11-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Strain optical fiber sensor with modified sensitivity based on the vernier effect\",\"authors\":\"D. Jáuregui-Vázquez, J. Korterik, H. Offerhaus, R. Rojas‐Laguna, J. Álvarez-Chávez\",\"doi\":\"10.1080/10739149.2022.2150005\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract An optical fiber strain sensor with adjustable sensitivity is proposed and demonstrated. The strain sensing setup employs a fiber optic Michelson interferometer (sensing element) and an extrinsic Fabry–Perot interferometer, in which both structures excited the Vernier effect. By adjusting the cavity length of the extrinsic Fabry–Perot interferometer, it is possible to control the M-factor. The set-up offers both sensitivity enhancement and magnification mode, where the maximal sensitivity is 4.38 pm/με (M-factor = 2.3). This design improves the sensor performance and its implementation is not intricate.\",\"PeriodicalId\":13547,\"journal\":{\"name\":\"Instrumentation Science & Technology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2022-11-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Instrumentation Science & Technology\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1080/10739149.2022.2150005\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Instrumentation Science & Technology","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1080/10739149.2022.2150005","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 1

摘要

摘要提出并演示了一种灵敏度可调的光纤应变传感器。应变传感装置采用光纤迈克尔逊干涉仪(传感元件)和非本征法布里-珀罗干涉仪,其中两种结构都激发了Vernier效应。通过调整本征法布里-珀罗干涉仪的腔长,可以控制M因子。该设置提供灵敏度增强和放大模式,其中最大灵敏度为4.38 pm/με(M因子=2.3)。这种设计提高了传感器的性能,并且其实现并不复杂。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Strain optical fiber sensor with modified sensitivity based on the vernier effect
Abstract An optical fiber strain sensor with adjustable sensitivity is proposed and demonstrated. The strain sensing setup employs a fiber optic Michelson interferometer (sensing element) and an extrinsic Fabry–Perot interferometer, in which both structures excited the Vernier effect. By adjusting the cavity length of the extrinsic Fabry–Perot interferometer, it is possible to control the M-factor. The set-up offers both sensitivity enhancement and magnification mode, where the maximal sensitivity is 4.38 pm/με (M-factor = 2.3). This design improves the sensor performance and its implementation is not intricate.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Instrumentation Science & Technology
Instrumentation Science & Technology 工程技术-分析化学
CiteScore
3.50
自引率
0.00%
发文量
45
审稿时长
>12 weeks
期刊介绍: Instrumentation Science & Technology is an internationally acclaimed forum for fast publication of critical, peer reviewed manuscripts dealing with innovative instrument design and applications in chemistry, physics biotechnology and environmental science. Particular attention is given to state-of-the-art developments and their rapid communication to the scientific community. Emphasis is on modern instrumental concepts, though not exclusively, including detectors, sensors, data acquisition and processing, instrument control, chromatography, electrochemistry, spectroscopy of all types, electrophoresis, radiometry, relaxation methods, thermal analysis, physical property measurements, surface physics, membrane technology, microcomputer design, chip-based processes, and more. Readership includes everyone who uses instrumental techniques to conduct their research and development. They are chemists (organic, inorganic, physical, analytical, nuclear, quality control) biochemists, biotechnologists, engineers, and physicists in all of the instrumental disciplines mentioned above, in both the laboratory and chemical production environments. The journal is an important resource of instrument design and applications data.
期刊最新文献
Determination of hepatitis B virus (HBV) DNA in serum by nucleic acid screening Nanostructure silver absorbance with polarized light spectroscopy (PLS) and mobile imaging Self-regulating pen-needle-based micronozzle for printing array of nanoliter droplets under fluorinated liquid Assembly and characterization of an optical fiber probe for use in a portable Raman spectrometer A pulsed current set-up for use in magnetic fields above 30 T; application to high-temperature superconductors
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1