{"title":"颈椎椎旁孔螺钉、侧块螺钉和椎弓根螺钉生物力学性能比较","authors":"Xi Chen, Xinyu Liu, Qing Yang, Yifan Liu, Suomao Yuan","doi":"10.3760/CMA.J.ISSN.0253-2352.2020.04.006","DOIUrl":null,"url":null,"abstract":"Objective \nTo investigate and compare the biomechanical strength of paravertebral foramen screws (PVFS), lateral mass screws (LMS) and pedicle screws (PS). \n \n \nMethods \nA total of 30 human cervical spine vertebrae (C3-C6) were harvested from 8 fresh-frozen cadaver specimens whose mean age was 45.3±11.2 years at death. The vertebrae were randomly divided into three groups for specific screws. For each vertebra, one side was randomly chosen for direct pullout strength test (speed 5 mm/s), and the other side for fatigue test (displacement ±1.0 mm, frequency 1 Hz, 500 cycles) and residual pullout strength test. 4.5 mm × 12 mm screws were used for PVFS, 3.5 mm × 14 mm screws for LMS, and 3.5 mm × 24 mm screws for PS. \n \n \nResults \nThe direct pullout strength was 327.10±17.07 N for PVFS, 305.71 ± 11.63 N for LMS, and 635.67 ± 22.82 N for PS. The residual pullout strength was 265.62 ±18.19 N for PVFS, 192.80 ±17.10 N for LMS, and 494.89 ±41.79 N for PS. The residual pullout strength of PVFS, LMS and PS respectively, compared with the direct pullout strength, decreased by 18.8%, 36.93% and 22.15% (tPVFS=7.795, tLMS=17.267, tPS=9.349, P<0.001). The direct pullout strength of PS was higher than that of PVFS and LMS(t=34.245, t=40.741, P< 0.001), as well as PVFS was slightly higher than LMS (t=3.275, P=0.004). The residual pullout strength of PS was the highest, PVFS was the second, and LMS was the smallest (F=314.619, P<0.001). For the fatigue test, the load at the first cycle and the first time when the set position was reached of PVFS were higher than those of LMS (t=3.625, P=0.002; t=5.388, P<0.001) and PS (t=2.575, P=0.019; t=2.680, P=0.015), but there was no difference between those of LMS and PS (t=0.609, P=0.550; t=1.953, P=0.067). The load at the last cycle of PVFS and PS was higher than that of LMS (t=5.341, P<0.001; t=3.439, P=0.003), while there was no difference between PVFS and PS (t=1.606, P=0.126). \n \n \nConclusion \nThe direct pullout strength of PVFS was slightly higher than that of LMS, and the residual pullout strength was significantly higher than LMS. The property of fatigue resistance of PVFS was similar to PS and obviously better than LMS. In summary, PVFS can be used as an effective substitute for LMS and PS. \n \n \nKey words: \nCervical vertebrae; Spinal fusion; Bone screws; Biomechanics","PeriodicalId":36405,"journal":{"name":"中华骨科杂志","volume":"40 1","pages":"236-243"},"PeriodicalIF":0.0000,"publicationDate":"2020-02-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparison of biomechanical properties of cervical paravertebral foramen screws, lateral mass screws and pedicle screws\",\"authors\":\"Xi Chen, Xinyu Liu, Qing Yang, Yifan Liu, Suomao Yuan\",\"doi\":\"10.3760/CMA.J.ISSN.0253-2352.2020.04.006\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Objective \\nTo investigate and compare the biomechanical strength of paravertebral foramen screws (PVFS), lateral mass screws (LMS) and pedicle screws (PS). \\n \\n \\nMethods \\nA total of 30 human cervical spine vertebrae (C3-C6) were harvested from 8 fresh-frozen cadaver specimens whose mean age was 45.3±11.2 years at death. The vertebrae were randomly divided into three groups for specific screws. For each vertebra, one side was randomly chosen for direct pullout strength test (speed 5 mm/s), and the other side for fatigue test (displacement ±1.0 mm, frequency 1 Hz, 500 cycles) and residual pullout strength test. 4.5 mm × 12 mm screws were used for PVFS, 3.5 mm × 14 mm screws for LMS, and 3.5 mm × 24 mm screws for PS. \\n \\n \\nResults \\nThe direct pullout strength was 327.10±17.07 N for PVFS, 305.71 ± 11.63 N for LMS, and 635.67 ± 22.82 N for PS. The residual pullout strength was 265.62 ±18.19 N for PVFS, 192.80 ±17.10 N for LMS, and 494.89 ±41.79 N for PS. The residual pullout strength of PVFS, LMS and PS respectively, compared with the direct pullout strength, decreased by 18.8%, 36.93% and 22.15% (tPVFS=7.795, tLMS=17.267, tPS=9.349, P<0.001). The direct pullout strength of PS was higher than that of PVFS and LMS(t=34.245, t=40.741, P< 0.001), as well as PVFS was slightly higher than LMS (t=3.275, P=0.004). The residual pullout strength of PS was the highest, PVFS was the second, and LMS was the smallest (F=314.619, P<0.001). For the fatigue test, the load at the first cycle and the first time when the set position was reached of PVFS were higher than those of LMS (t=3.625, P=0.002; t=5.388, P<0.001) and PS (t=2.575, P=0.019; t=2.680, P=0.015), but there was no difference between those of LMS and PS (t=0.609, P=0.550; t=1.953, P=0.067). The load at the last cycle of PVFS and PS was higher than that of LMS (t=5.341, P<0.001; t=3.439, P=0.003), while there was no difference between PVFS and PS (t=1.606, P=0.126). \\n \\n \\nConclusion \\nThe direct pullout strength of PVFS was slightly higher than that of LMS, and the residual pullout strength was significantly higher than LMS. The property of fatigue resistance of PVFS was similar to PS and obviously better than LMS. In summary, PVFS can be used as an effective substitute for LMS and PS. \\n \\n \\nKey words: \\nCervical vertebrae; Spinal fusion; Bone screws; Biomechanics\",\"PeriodicalId\":36405,\"journal\":{\"name\":\"中华骨科杂志\",\"volume\":\"40 1\",\"pages\":\"236-243\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-02-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"中华骨科杂志\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3760/CMA.J.ISSN.0253-2352.2020.04.006\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"中华骨科杂志","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3760/CMA.J.ISSN.0253-2352.2020.04.006","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

目的比较椎旁孔螺钉(PVFS)、侧块螺钉(LMS)和椎弓根螺钉(PS)的生物力学强度。方法从8具死亡时平均年龄为45.3±11.2岁的新鲜冷冻尸体标本中采集30块人颈椎(C3-C6)。脊椎被随机分为三组,用于特定的螺钉。对于每个椎骨,随机选择一侧进行直接拉拔强度试验(速度5mm/s),另一侧进行疲劳试验(位移±1.0mm,频率1Hz,500个循环)和残余拉拔强度试验。结果PVFS的直接拔出强度为327.10±17.07N,LMS为305.71±11.63N,PS为635.67±22.82N。PVFS的残余拔出强度分别为265.62±18.19N、192.80±17.10N和494.89±41.79N,LMS和PS的直接拉拔强度分别比直接拉拔强度下降18.8%、36.93%和22.15%(tPVFS=7.795,tLS=17.267,tPS=9.349,P<0.001),在疲劳试验中,PVFS的第一个循环和第一次到达设定位置时的载荷高于LMS(t=3.625,P=0.002;t=5.388,P<0.001)和PS(t=2.575,P=0.019;t=2.680,P=0.015),但LMS和PS之间没有差异(t=0.609,P=0.550;t=1.953,P=0.067)。PVFS和PS在最后一个周期的载荷高于LMS(t=5.341,P<0.001;t=3.439,P=0.003),而PVFS和PS之间没有差别(t=1.606,P=0.126)。结论PVFS的直接拔出强度略高于LMS,并且残余拔出强度显著高于LMS。PVFS的抗疲劳性能与PS相近,明显优于LMS。总之,PVFS可以作为LMS和PS的有效替代品。关键词:颈椎;脊柱融合术;骨螺钉;生物力学
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Comparison of biomechanical properties of cervical paravertebral foramen screws, lateral mass screws and pedicle screws
Objective To investigate and compare the biomechanical strength of paravertebral foramen screws (PVFS), lateral mass screws (LMS) and pedicle screws (PS). Methods A total of 30 human cervical spine vertebrae (C3-C6) were harvested from 8 fresh-frozen cadaver specimens whose mean age was 45.3±11.2 years at death. The vertebrae were randomly divided into three groups for specific screws. For each vertebra, one side was randomly chosen for direct pullout strength test (speed 5 mm/s), and the other side for fatigue test (displacement ±1.0 mm, frequency 1 Hz, 500 cycles) and residual pullout strength test. 4.5 mm × 12 mm screws were used for PVFS, 3.5 mm × 14 mm screws for LMS, and 3.5 mm × 24 mm screws for PS. Results The direct pullout strength was 327.10±17.07 N for PVFS, 305.71 ± 11.63 N for LMS, and 635.67 ± 22.82 N for PS. The residual pullout strength was 265.62 ±18.19 N for PVFS, 192.80 ±17.10 N for LMS, and 494.89 ±41.79 N for PS. The residual pullout strength of PVFS, LMS and PS respectively, compared with the direct pullout strength, decreased by 18.8%, 36.93% and 22.15% (tPVFS=7.795, tLMS=17.267, tPS=9.349, P<0.001). The direct pullout strength of PS was higher than that of PVFS and LMS(t=34.245, t=40.741, P< 0.001), as well as PVFS was slightly higher than LMS (t=3.275, P=0.004). The residual pullout strength of PS was the highest, PVFS was the second, and LMS was the smallest (F=314.619, P<0.001). For the fatigue test, the load at the first cycle and the first time when the set position was reached of PVFS were higher than those of LMS (t=3.625, P=0.002; t=5.388, P<0.001) and PS (t=2.575, P=0.019; t=2.680, P=0.015), but there was no difference between those of LMS and PS (t=0.609, P=0.550; t=1.953, P=0.067). The load at the last cycle of PVFS and PS was higher than that of LMS (t=5.341, P<0.001; t=3.439, P=0.003), while there was no difference between PVFS and PS (t=1.606, P=0.126). Conclusion The direct pullout strength of PVFS was slightly higher than that of LMS, and the residual pullout strength was significantly higher than LMS. The property of fatigue resistance of PVFS was similar to PS and obviously better than LMS. In summary, PVFS can be used as an effective substitute for LMS and PS. Key words: Cervical vertebrae; Spinal fusion; Bone screws; Biomechanics
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
中华骨科杂志
中华骨科杂志 Medicine-Surgery
CiteScore
0.80
自引率
0.00%
发文量
8153
期刊介绍:
期刊最新文献
A comparative study of the efficacy and complications of oblique lumbar interbody fusion and transforaminal lumbar interbody fusion in lumbar degenerative scoliosis A comparative study on the treatment of degenerative lumbar spondylolisthesis by oblique interbody fusion and minimally invasive transforminal lumbar interbody fusion Rooting, and growing with luxuriant branches and leaves-the story of oblique lateral interbody fusion in China Percutaneous endoscopic lumbar discectomy combined with oblique lateral interbody fusion for degenerative lumbar diseases with ruptured disc herniation The complications of oblique lateral interbody fusion procedure
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1