基于可靠性的缆索支撑桥梁甲板火灾结构缆索防火

IF 1.1 4区 工程技术 Q3 CONSTRUCTION & BUILDING TECHNOLOGY Structural Engineering International Pub Date : 2023-08-10 DOI:10.1080/10168664.2023.2213257
P. Kotsovinos, Y. Panev, Heikki Lilja, Atte Mikkonen, Alberto Carlucci, P. Woodburn
{"title":"基于可靠性的缆索支撑桥梁甲板火灾结构缆索防火","authors":"P. Kotsovinos, Y. Panev, Heikki Lilja, Atte Mikkonen, Alberto Carlucci, P. Woodburn","doi":"10.1080/10168664.2023.2213257","DOIUrl":null,"url":null,"abstract":"Abstract Cable supported bridges are typically part of community-critical infrastructure and therefore the consequences arising from extensive structural damage due to a fire and the subsequent operational discontinuity could be significant beyond the damage to the bridge itself and the cost of repairs. Bridge design standards generally do not provide guidance and hence fire resistance requirements are often informed by first principles assessments of the thermal and structural response of the structure to proposed fire scenarios. A deterministic assessment can provide a reasonable worst-case scenario but it does not allow bridge stakeholders to make informed decisions with regards to uncertainty and the low likelihood of fires occurring to identify the benefits of investments in structural fire protection. This is because the target reliability required for each bridge may be different depending on its characteristics, and the expected fire severity has a probabilistic nature. This research aims to fill this gap by undertaking a reliability-based analysis to assess the probability of structural failure by considering the probability of a fire of a given size occurring and the uncertainty in the incident location and wind. The methodology is demonstrated through the case study of an operational 450 m long cable supported bridge section and a fire scenario based on a liquid fuel tanker. Liquid tankers can result into two type of fire scenario: first, a fire being contained within the tanker; and secondly, a fire due to a pool on the deck. Both fire scenarios have been characterised and it was determined that the contained tanker scenario presents a more onerous design case owing to its more prolonged duration. A Monte Carlo analysis was undertaken for a total of 10,000 independent trials of the combination of the location of the fire and the wind direction. The frequency of the fire was also examined to establish the probability of structural failure of a cable. It was established that the inclusion of wind can sometimes reduce the estimated height at which cables may experience temperatures with the potential to cause cable failure. However, for a number of the cases, the estimated height can remain broadly similar (i.e. within a couple metres difference) to the worst-case calculated value. Based on this analysis, the influence of the required level of reliability as well the fire protection duration specification agreed with bridge stakeholders can be used to determine the height at which cable fire protection is necessary to reduce the probability of structural failure to a level acceptable to the stakeholders. This approach allows bridge designers and stakeholders to make informed decisions with regards to provision and extent of fire preventive/protective measures for cable supported bridges.","PeriodicalId":51281,"journal":{"name":"Structural Engineering International","volume":" ","pages":""},"PeriodicalIF":1.1000,"publicationDate":"2023-08-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Reliability-based Fire Protection of Structural Cables due to Deck Fires on Cable Supported Bridges\",\"authors\":\"P. Kotsovinos, Y. Panev, Heikki Lilja, Atte Mikkonen, Alberto Carlucci, P. Woodburn\",\"doi\":\"10.1080/10168664.2023.2213257\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract Cable supported bridges are typically part of community-critical infrastructure and therefore the consequences arising from extensive structural damage due to a fire and the subsequent operational discontinuity could be significant beyond the damage to the bridge itself and the cost of repairs. Bridge design standards generally do not provide guidance and hence fire resistance requirements are often informed by first principles assessments of the thermal and structural response of the structure to proposed fire scenarios. A deterministic assessment can provide a reasonable worst-case scenario but it does not allow bridge stakeholders to make informed decisions with regards to uncertainty and the low likelihood of fires occurring to identify the benefits of investments in structural fire protection. This is because the target reliability required for each bridge may be different depending on its characteristics, and the expected fire severity has a probabilistic nature. This research aims to fill this gap by undertaking a reliability-based analysis to assess the probability of structural failure by considering the probability of a fire of a given size occurring and the uncertainty in the incident location and wind. The methodology is demonstrated through the case study of an operational 450 m long cable supported bridge section and a fire scenario based on a liquid fuel tanker. Liquid tankers can result into two type of fire scenario: first, a fire being contained within the tanker; and secondly, a fire due to a pool on the deck. Both fire scenarios have been characterised and it was determined that the contained tanker scenario presents a more onerous design case owing to its more prolonged duration. A Monte Carlo analysis was undertaken for a total of 10,000 independent trials of the combination of the location of the fire and the wind direction. The frequency of the fire was also examined to establish the probability of structural failure of a cable. It was established that the inclusion of wind can sometimes reduce the estimated height at which cables may experience temperatures with the potential to cause cable failure. However, for a number of the cases, the estimated height can remain broadly similar (i.e. within a couple metres difference) to the worst-case calculated value. Based on this analysis, the influence of the required level of reliability as well the fire protection duration specification agreed with bridge stakeholders can be used to determine the height at which cable fire protection is necessary to reduce the probability of structural failure to a level acceptable to the stakeholders. This approach allows bridge designers and stakeholders to make informed decisions with regards to provision and extent of fire preventive/protective measures for cable supported bridges.\",\"PeriodicalId\":51281,\"journal\":{\"name\":\"Structural Engineering International\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2023-08-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Structural Engineering International\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1080/10168664.2023.2213257\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CONSTRUCTION & BUILDING TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Structural Engineering International","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1080/10168664.2023.2213257","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 1
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Reliability-based Fire Protection of Structural Cables due to Deck Fires on Cable Supported Bridges
Abstract Cable supported bridges are typically part of community-critical infrastructure and therefore the consequences arising from extensive structural damage due to a fire and the subsequent operational discontinuity could be significant beyond the damage to the bridge itself and the cost of repairs. Bridge design standards generally do not provide guidance and hence fire resistance requirements are often informed by first principles assessments of the thermal and structural response of the structure to proposed fire scenarios. A deterministic assessment can provide a reasonable worst-case scenario but it does not allow bridge stakeholders to make informed decisions with regards to uncertainty and the low likelihood of fires occurring to identify the benefits of investments in structural fire protection. This is because the target reliability required for each bridge may be different depending on its characteristics, and the expected fire severity has a probabilistic nature. This research aims to fill this gap by undertaking a reliability-based analysis to assess the probability of structural failure by considering the probability of a fire of a given size occurring and the uncertainty in the incident location and wind. The methodology is demonstrated through the case study of an operational 450 m long cable supported bridge section and a fire scenario based on a liquid fuel tanker. Liquid tankers can result into two type of fire scenario: first, a fire being contained within the tanker; and secondly, a fire due to a pool on the deck. Both fire scenarios have been characterised and it was determined that the contained tanker scenario presents a more onerous design case owing to its more prolonged duration. A Monte Carlo analysis was undertaken for a total of 10,000 independent trials of the combination of the location of the fire and the wind direction. The frequency of the fire was also examined to establish the probability of structural failure of a cable. It was established that the inclusion of wind can sometimes reduce the estimated height at which cables may experience temperatures with the potential to cause cable failure. However, for a number of the cases, the estimated height can remain broadly similar (i.e. within a couple metres difference) to the worst-case calculated value. Based on this analysis, the influence of the required level of reliability as well the fire protection duration specification agreed with bridge stakeholders can be used to determine the height at which cable fire protection is necessary to reduce the probability of structural failure to a level acceptable to the stakeholders. This approach allows bridge designers and stakeholders to make informed decisions with regards to provision and extent of fire preventive/protective measures for cable supported bridges.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Structural Engineering International
Structural Engineering International CONSTRUCTION & BUILDING TECHNOLOGY-ENGINEERING, CIVIL
CiteScore
2.60
自引率
9.10%
发文量
78
审稿时长
6-12 weeks
期刊介绍: The aim of the Association is to exchange knowledge and to advance the practice of structural engineering worldwide in the service of the profession and society.
期刊最新文献
Investigation of an Ancient Wooden Cantilever Covered Bridge in China: Construction Form and Mechanical Properties Technologies and Platforms for Remote and Autonomous Bridge Inspection – Review Simplified Procedure for the Design and Optimisation of Oval Tensile Spoke Wheels for Roof Structures Shennong Lake Bridge: A Parameterized-Designed Single Tower Cable-Stayed Bridge Temperature Control and Crack Prevention of High RCC Dam in Cold and Drought Area
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1