E. M. Borges, G. Sabundjian, F. D’Auria, A. Petruzzi
{"title":"安格拉2号核电站热腿应急堆芯冷却系统小断口失稳的不确定性计算","authors":"E. M. Borges, G. Sabundjian, F. D’Auria, A. Petruzzi","doi":"10.1504/IJNEST.2018.094284","DOIUrl":null,"url":null,"abstract":"Owing to the occurrence of nuclear accidents, worldwide nuclear regulatory organisations included the analysis of accidents considered as design basis accidents - Loss of Coolant Accident (large and small-break, LBLOCA or SBLOCA) - in the safety analysis reports of nuclear facilities. In Brazil, the tool selected by the licensing authority, Comissao Nacional de Energia Nuclear (CNEN), is RELAP5 Code. The aim of this paper is the evaluation of the performance of the Emergency Core Cooling System (ECCS) of Angra 2 nuclear reactor during SBLOCA. In this study, the RELAP5 code and the Code Internal Assessment of Uncertainty (CIAU) were used to simulate and analyse the uncertainties of the results. The postulated accident is the SBLOCA in the hot leg connected to the ECCS described in the Final Safety Analysis Report of Angra 2 (FSAR/A2). The results from this study were satisfactory when compared with the FSAR/A2.","PeriodicalId":35144,"journal":{"name":"International Journal of Nuclear Energy Science and Technology","volume":"12 1","pages":"139-160"},"PeriodicalIF":0.0000,"publicationDate":"2018-08-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1504/IJNEST.2018.094284","citationCount":"0","resultStr":"{\"title\":\"Uncertainty calculation in small break LOCA in the emergency core cooling system connected to the hot leg of Angra 2 nuclear power plant\",\"authors\":\"E. M. Borges, G. Sabundjian, F. D’Auria, A. Petruzzi\",\"doi\":\"10.1504/IJNEST.2018.094284\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Owing to the occurrence of nuclear accidents, worldwide nuclear regulatory organisations included the analysis of accidents considered as design basis accidents - Loss of Coolant Accident (large and small-break, LBLOCA or SBLOCA) - in the safety analysis reports of nuclear facilities. In Brazil, the tool selected by the licensing authority, Comissao Nacional de Energia Nuclear (CNEN), is RELAP5 Code. The aim of this paper is the evaluation of the performance of the Emergency Core Cooling System (ECCS) of Angra 2 nuclear reactor during SBLOCA. In this study, the RELAP5 code and the Code Internal Assessment of Uncertainty (CIAU) were used to simulate and analyse the uncertainties of the results. The postulated accident is the SBLOCA in the hot leg connected to the ECCS described in the Final Safety Analysis Report of Angra 2 (FSAR/A2). The results from this study were satisfactory when compared with the FSAR/A2.\",\"PeriodicalId\":35144,\"journal\":{\"name\":\"International Journal of Nuclear Energy Science and Technology\",\"volume\":\"12 1\",\"pages\":\"139-160\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-08-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1504/IJNEST.2018.094284\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Nuclear Energy Science and Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1504/IJNEST.2018.094284\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Energy\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Nuclear Energy Science and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1504/IJNEST.2018.094284","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Energy","Score":null,"Total":0}
Uncertainty calculation in small break LOCA in the emergency core cooling system connected to the hot leg of Angra 2 nuclear power plant
Owing to the occurrence of nuclear accidents, worldwide nuclear regulatory organisations included the analysis of accidents considered as design basis accidents - Loss of Coolant Accident (large and small-break, LBLOCA or SBLOCA) - in the safety analysis reports of nuclear facilities. In Brazil, the tool selected by the licensing authority, Comissao Nacional de Energia Nuclear (CNEN), is RELAP5 Code. The aim of this paper is the evaluation of the performance of the Emergency Core Cooling System (ECCS) of Angra 2 nuclear reactor during SBLOCA. In this study, the RELAP5 code and the Code Internal Assessment of Uncertainty (CIAU) were used to simulate and analyse the uncertainties of the results. The postulated accident is the SBLOCA in the hot leg connected to the ECCS described in the Final Safety Analysis Report of Angra 2 (FSAR/A2). The results from this study were satisfactory when compared with the FSAR/A2.
期刊介绍:
Today, nuclear reactors generate nearly one quarter of the electricity in nations representing two thirds of humanity, and other nuclear applications are integral to many aspects of the world economy. Nuclear fission remains an important option for meeting energy requirements and maintaining a balanced worldwide energy policy; with major countries expanding nuclear energy"s role and new countries poised to introduce it, the key issue is not whether the use of nuclear technology will grow worldwide, even if public opinion concerning safety, the economics of nuclear power, and waste disposal issues adversely affect the general acceptance of nuclear power, but whether it will grow fast enough to make a decisive contribution to the global imperative of sustainable development.