{"title":"紫外分光光度法和HPLC-PDA法同时测定依泊那瑞格列嗪和维达格利汀片剂的含量","authors":"R. Kotadiya, Prachi Joshi","doi":"10.25135/jcm.82.2301.2693","DOIUrl":null,"url":null,"abstract":": Objectives: The ultraviolet spectrophotometric and reversed-phase high-performance liquid chromatography methods were developed and validated to quantify remogliflozin etabonate and vildagliptin in a fixed-dose tablet formulation. The materials and methods used in this study involved using methanol as the solvent in developing three ultraviolet spectrophotometric techniques, namely simultaneous equation, absorption ratio, and derivative spectroscopy. The wavelength maxima for vildagliptin and remogliflozin etabonate were determined to be 232 nm and 217 nm, respectively. The chromatographic method involved using a Phenomenex Luna C18 column (250 × 4.6 mm, 5 µm) and a mobile phase consisting of a mixture of methanol and acetate buffer (pH 5.6) in a 70:30 ratio. The flow rate was set at 1 mL/min, and the detecting wavelength was 210 nm. The results obtained from the optimized approaches met the performance test criteria set by the International Conference on Harmonization guideline Q2 (R1). The methods were then applied to assay marketed tablet formulations, and the results obtained were within acceptable limits. In conclusion, the developed techniques can be used to analyze the fixed-dose tablet formulation regularly.","PeriodicalId":15343,"journal":{"name":"Journal of Chemical Metrology","volume":" ","pages":""},"PeriodicalIF":1.8000,"publicationDate":"2023-03-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Simultaneous estimation of remogliflozin etabonate and vildagliptin in a tablet formulation: UV spectrophotometric and HPLC-PDA method\",\"authors\":\"R. Kotadiya, Prachi Joshi\",\"doi\":\"10.25135/jcm.82.2301.2693\",\"DOIUrl\":null,\"url\":null,\"abstract\":\": Objectives: The ultraviolet spectrophotometric and reversed-phase high-performance liquid chromatography methods were developed and validated to quantify remogliflozin etabonate and vildagliptin in a fixed-dose tablet formulation. The materials and methods used in this study involved using methanol as the solvent in developing three ultraviolet spectrophotometric techniques, namely simultaneous equation, absorption ratio, and derivative spectroscopy. The wavelength maxima for vildagliptin and remogliflozin etabonate were determined to be 232 nm and 217 nm, respectively. The chromatographic method involved using a Phenomenex Luna C18 column (250 × 4.6 mm, 5 µm) and a mobile phase consisting of a mixture of methanol and acetate buffer (pH 5.6) in a 70:30 ratio. The flow rate was set at 1 mL/min, and the detecting wavelength was 210 nm. The results obtained from the optimized approaches met the performance test criteria set by the International Conference on Harmonization guideline Q2 (R1). The methods were then applied to assay marketed tablet formulations, and the results obtained were within acceptable limits. In conclusion, the developed techniques can be used to analyze the fixed-dose tablet formulation regularly.\",\"PeriodicalId\":15343,\"journal\":{\"name\":\"Journal of Chemical Metrology\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2023-03-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Chemical Metrology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.25135/jcm.82.2301.2693\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Chemical Metrology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.25135/jcm.82.2301.2693","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

:目的:建立并验证了紫外分光光度法和反相高效液相色谱法对固定剂量片剂中的依泊净和维达格利汀进行定量。本研究中使用的材料和方法包括以甲醇为溶剂开发三种紫外分光光度法,即联立方程、吸收比和导数光谱法。维达列汀和瑞格列嗪依他波酸的最大波长分别为232nm和217nm。色谱方法包括使用Phenomenex Luna C18柱(250×4.6 mm,5µm)和流动相,流动相由甲醇和乙酸缓冲液(pH 5.6)的混合物组成,比例为70:30。流速设定为1mL/min,检测波长为210nm。从优化方法中获得的结果符合国际协调会议准则Q2(R1)制定的性能测试标准。然后将这些方法应用于市场上销售的片剂配方的测定,得到的结果在可接受的限度内。总之,所开发的技术可以用于定期分析固定剂量片剂的配方。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Simultaneous estimation of remogliflozin etabonate and vildagliptin in a tablet formulation: UV spectrophotometric and HPLC-PDA method
: Objectives: The ultraviolet spectrophotometric and reversed-phase high-performance liquid chromatography methods were developed and validated to quantify remogliflozin etabonate and vildagliptin in a fixed-dose tablet formulation. The materials and methods used in this study involved using methanol as the solvent in developing three ultraviolet spectrophotometric techniques, namely simultaneous equation, absorption ratio, and derivative spectroscopy. The wavelength maxima for vildagliptin and remogliflozin etabonate were determined to be 232 nm and 217 nm, respectively. The chromatographic method involved using a Phenomenex Luna C18 column (250 × 4.6 mm, 5 µm) and a mobile phase consisting of a mixture of methanol and acetate buffer (pH 5.6) in a 70:30 ratio. The flow rate was set at 1 mL/min, and the detecting wavelength was 210 nm. The results obtained from the optimized approaches met the performance test criteria set by the International Conference on Harmonization guideline Q2 (R1). The methods were then applied to assay marketed tablet formulations, and the results obtained were within acceptable limits. In conclusion, the developed techniques can be used to analyze the fixed-dose tablet formulation regularly.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Chemical Metrology
Journal of Chemical Metrology CHEMISTRY, ANALYTICAL-
CiteScore
2.30
自引率
15.40%
发文量
7
期刊最新文献
Gradient reversed-phase HPLC method for the quantitation of azelnidipine and chlorthalidone in a fixed-dose synthetic mixture A new HPLC-UV method for the simultaneous measurements of α-escin and β-escin in creams containing Aesculus hippocastanum L. extract Quantification of main secondary metabolites of Satureja icarica P.H. Davis (Lamiaceae) by LC-HRMS and evaluation of antioxidant capacities An effective HPLC method for evaluation of process related impurities of Letermovir and LC-MS/MS characterization of forced degradation compounds A validated RP-HPLC assay method for Tofacitinib in pharmaceutical drug products
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1