阻碍Pb2+在黄土改良土壤-膨润土屏障中迁移的离心机模拟

IF 1.2 4区 工程技术 Q4 ENGINEERING, GEOLOGICAL International Journal of Physical Modelling in Geotechnics Pub Date : 2022-02-28 DOI:10.1680/jphmg.21.00007
L. Zhan, Y. You, Rui Zhao, Cheng Chen, Yun-min Chen
{"title":"阻碍Pb2+在黄土改良土壤-膨润土屏障中迁移的离心机模拟","authors":"L. Zhan, Y. You, Rui Zhao, Cheng Chen, Yun-min Chen","doi":"10.1680/jphmg.21.00007","DOIUrl":null,"url":null,"abstract":"Soil-bentonite (SB) walls are commonly used as barriers for in situ containments at landfills. SB walls are designed to control the movement of persistent pollutants such as heavy metals in the long term. This paper presents centrifuge and numerical modelling of 50 years of performance of a loess-amended SB (LSB) wall in comparison with a conventional SB wall. Both walls were 28 m high and subjected to a hydraulic head difference of 2 m in the prototype. A purposely-designed apparatus was developed to impose the hydraulic head and a pollutant loading of 200 mg/L lead(II) on two barriers simultaneously. The apparatus was loaded on the ZJU400 geotechnical centrifuge and spun to 100-g. Similitudes of dispersion and adsorption of lead(II) in a centrifuge were discussed. Stress redistribution was observed in small-scale walls due to the enhanced soil arching effect. The lead(II) migration distance in the LSB wall after 50 years was 44.3% shorter than that in the SB wall. The predicted breakthrough time for the LSB wall was 149.1% longer than that for the SB wall when the thickness was 0.6 m. Retardation effects could be attributed to the significant ability of loess to absorb lead(II).","PeriodicalId":48816,"journal":{"name":"International Journal of Physical Modelling in Geotechnics","volume":null,"pages":null},"PeriodicalIF":1.2000,"publicationDate":"2022-02-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Centrifuge Modelling of Retardation of Pb2+Migration in Loess–amended Soil–bentonite Barriers\",\"authors\":\"L. Zhan, Y. You, Rui Zhao, Cheng Chen, Yun-min Chen\",\"doi\":\"10.1680/jphmg.21.00007\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Soil-bentonite (SB) walls are commonly used as barriers for in situ containments at landfills. SB walls are designed to control the movement of persistent pollutants such as heavy metals in the long term. This paper presents centrifuge and numerical modelling of 50 years of performance of a loess-amended SB (LSB) wall in comparison with a conventional SB wall. Both walls were 28 m high and subjected to a hydraulic head difference of 2 m in the prototype. A purposely-designed apparatus was developed to impose the hydraulic head and a pollutant loading of 200 mg/L lead(II) on two barriers simultaneously. The apparatus was loaded on the ZJU400 geotechnical centrifuge and spun to 100-g. Similitudes of dispersion and adsorption of lead(II) in a centrifuge were discussed. Stress redistribution was observed in small-scale walls due to the enhanced soil arching effect. The lead(II) migration distance in the LSB wall after 50 years was 44.3% shorter than that in the SB wall. The predicted breakthrough time for the LSB wall was 149.1% longer than that for the SB wall when the thickness was 0.6 m. Retardation effects could be attributed to the significant ability of loess to absorb lead(II).\",\"PeriodicalId\":48816,\"journal\":{\"name\":\"International Journal of Physical Modelling in Geotechnics\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2022-02-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Physical Modelling in Geotechnics\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1680/jphmg.21.00007\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, GEOLOGICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Physical Modelling in Geotechnics","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1680/jphmg.21.00007","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, GEOLOGICAL","Score":null,"Total":0}
引用次数: 1

摘要

土-膨润土(SB)墙通常用作垃圾填埋场的原位密封屏障。SB墙的设计是为了长期控制重金属等持久性污染物的移动。本文介绍了黄土修正SB (LSB)墙50年性能的离心机和数值模拟,并与传统SB墙进行了比较。两面墙都是28米高,原型机的水头差为2米。研制了一种专门设计的装置,在两个障碍物上同时施加液压头和200 mg/L铅(II)的污染物负荷。将仪器装入ZJU400土工离心机,旋转至100 g。讨论了铅(II)在离心机中的分散和吸附的相似之处。由于土拱效应的增强,在小尺度墙体中观察到应力重分布。50年后铅(II)在LSB壁的迁移距离比在SB壁的迁移距离短44.3%。厚度为0.6 m时,LSB壁的预测突破时间比SB壁的预测突破时间长149.1%。黄土对铅(II)具有显著的吸附能力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Centrifuge Modelling of Retardation of Pb2+Migration in Loess–amended Soil–bentonite Barriers
Soil-bentonite (SB) walls are commonly used as barriers for in situ containments at landfills. SB walls are designed to control the movement of persistent pollutants such as heavy metals in the long term. This paper presents centrifuge and numerical modelling of 50 years of performance of a loess-amended SB (LSB) wall in comparison with a conventional SB wall. Both walls were 28 m high and subjected to a hydraulic head difference of 2 m in the prototype. A purposely-designed apparatus was developed to impose the hydraulic head and a pollutant loading of 200 mg/L lead(II) on two barriers simultaneously. The apparatus was loaded on the ZJU400 geotechnical centrifuge and spun to 100-g. Similitudes of dispersion and adsorption of lead(II) in a centrifuge were discussed. Stress redistribution was observed in small-scale walls due to the enhanced soil arching effect. The lead(II) migration distance in the LSB wall after 50 years was 44.3% shorter than that in the SB wall. The predicted breakthrough time for the LSB wall was 149.1% longer than that for the SB wall when the thickness was 0.6 m. Retardation effects could be attributed to the significant ability of loess to absorb lead(II).
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.60
自引率
15.80%
发文量
26
期刊介绍: International Journal of Physical Modelling in Geotechnics contains the latest research and analysis in all areas of physical modelling at any scale, including modelling at single gravity and at multiple gravities on a centrifuge, shaking table and pressure chamber testing and geoenvironmental experiments.
期刊最新文献
Effect of facing stiffness on GRS walls under surcharge loading-unloading Centrifuge modelling of groundwater variation induced settlement using different scaling methods Physical model test study on strength characteristics of gravel pile composite foundation Pressure and thermal effects on Rayleigh fiber-optic strain measurment for soil-structure interaction Scaling laws for the modelling of energy geostructures
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1