{"title":"风电转换系统同步发电机匝间短路故障的无传感器控制与诊断","authors":"S. Bouslimani, S. Drid, L. Chrifi-Alaoui","doi":"10.1504/IJPEC.2019.10012581","DOIUrl":null,"url":null,"abstract":"This paper deals with control and diagnosis of the synchronous generator (SG) used in a wind energy conversion system under inter turn short-circuit fault. In the first part of this paper, a speed sensorless control of the synchronous generator is presented. In this case speed estimation is carried out using model reference adaptive system (MRAS). In the second part, the MRAS observer is associated with the Luenberger observer in order to estimate the stator resistances according d and q axis. The stability of the system is proved by using Lyapunov theory. Finally, the proposed new hybrid observer MRAS-Luenberger is used to detect the turn-to-turn short circuit faults. The Park's vector approach (PVA) is adopted to take decision if there are faults. The proposed technique is tested on dSPACE DS1103 and the results confirm the efficacy to detect the fault by observing the shape. This method gives us the right information for the fault isolation.","PeriodicalId":38524,"journal":{"name":"International Journal of Power and Energy Conversion","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2019-09-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Sensorless control and diagnosis of synchronous generator used in wind energy conversion system under inter turn short-circuit fault\",\"authors\":\"S. Bouslimani, S. Drid, L. Chrifi-Alaoui\",\"doi\":\"10.1504/IJPEC.2019.10012581\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper deals with control and diagnosis of the synchronous generator (SG) used in a wind energy conversion system under inter turn short-circuit fault. In the first part of this paper, a speed sensorless control of the synchronous generator is presented. In this case speed estimation is carried out using model reference adaptive system (MRAS). In the second part, the MRAS observer is associated with the Luenberger observer in order to estimate the stator resistances according d and q axis. The stability of the system is proved by using Lyapunov theory. Finally, the proposed new hybrid observer MRAS-Luenberger is used to detect the turn-to-turn short circuit faults. The Park's vector approach (PVA) is adopted to take decision if there are faults. The proposed technique is tested on dSPACE DS1103 and the results confirm the efficacy to detect the fault by observing the shape. This method gives us the right information for the fault isolation.\",\"PeriodicalId\":38524,\"journal\":{\"name\":\"International Journal of Power and Energy Conversion\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-09-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Power and Energy Conversion\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1504/IJPEC.2019.10012581\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Energy\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Power and Energy Conversion","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1504/IJPEC.2019.10012581","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Energy","Score":null,"Total":0}
Sensorless control and diagnosis of synchronous generator used in wind energy conversion system under inter turn short-circuit fault
This paper deals with control and diagnosis of the synchronous generator (SG) used in a wind energy conversion system under inter turn short-circuit fault. In the first part of this paper, a speed sensorless control of the synchronous generator is presented. In this case speed estimation is carried out using model reference adaptive system (MRAS). In the second part, the MRAS observer is associated with the Luenberger observer in order to estimate the stator resistances according d and q axis. The stability of the system is proved by using Lyapunov theory. Finally, the proposed new hybrid observer MRAS-Luenberger is used to detect the turn-to-turn short circuit faults. The Park's vector approach (PVA) is adopted to take decision if there are faults. The proposed technique is tested on dSPACE DS1103 and the results confirm the efficacy to detect the fault by observing the shape. This method gives us the right information for the fault isolation.
期刊介绍:
IJPEC highlights the latest trends in research in the field of power generation, transmission and distribution. Currently there exist significant challenges in the power sector, particularly in deregulated/restructured power markets. A key challenge to the operation, control and protection of the power system is the proliferation of power electronic devices within power systems. The main thrust of IJPEC is to disseminate the latest research trends in the power sector as well as in energy conversion technologies. Topics covered include: -Power system modelling and analysis -Computing and economics -FACTS and HVDC -Challenges in restructured energy systems -Power system control, operation, communications, SCADA -Power system relaying/protection -Energy management systems/distribution automation -Applications of power electronics to power systems -Power quality -Distributed generation and renewable energy sources -Electrical machines and drives -Utilisation of electrical energy -Modelling and control of machines -Fault diagnosis in machines and drives -Special machines