太阳能DC-AC逆变器的鲁棒分数阶滑模控制

Q3 Energy Journal of Energy Systems Pub Date : 2020-12-31 DOI:10.30521/jes.737264
Shaik Silar Saheb, S. Gudey
{"title":"太阳能DC-AC逆变器的鲁棒分数阶滑模控制","authors":"Shaik Silar Saheb, S. Gudey","doi":"10.30521/jes.737264","DOIUrl":null,"url":null,"abstract":": Fractional order sliding mode control (FOSMC) strategy for a solar based DC-AC inverter is presented in this work. First FOSMC is implemented to voltage source inverter with a fixed DC input voltage of 400V to drive a load of 2.3 kW at a power factor of 0.8 lag. Here the load voltage and current through capacitor as state variables and a linear sliding surface are considered. FOSMC using Gao’s reaching law is derived for inverter circuit. FOSMC is implemented at load bus to control output voltage of inverter with linear and nonlinear loads to desired values. FOSMC controls the output voltage with good voltage regulation, less steady state error of 1.32 %, settling time of 0.15 ms, good dynamic response, and convergence to origin with less chattering compared to classical SMC. FOSMC based solar based VSI is presented. The maximum power from PV array is extracted using P&O MPPT algorithm. A boost converter is used to step up input voltage of 200 V to 400 V. P-V and I-V characteristics are obtained for a typical solar cell of 2.5 kW FOSMC requires less control efforts to obtain a pure sinusoidal output voltage waveform of 230 V (rms) with output voltage THD of 0.135% well within IEEE standards. PSCAD/EMTDC v4.6 is used for simulation work","PeriodicalId":52308,"journal":{"name":"Journal of Energy Systems","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2020-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Robust fractional order sliding mode control for solar based DC-AC inverter\",\"authors\":\"Shaik Silar Saheb, S. Gudey\",\"doi\":\"10.30521/jes.737264\",\"DOIUrl\":null,\"url\":null,\"abstract\":\": Fractional order sliding mode control (FOSMC) strategy for a solar based DC-AC inverter is presented in this work. First FOSMC is implemented to voltage source inverter with a fixed DC input voltage of 400V to drive a load of 2.3 kW at a power factor of 0.8 lag. Here the load voltage and current through capacitor as state variables and a linear sliding surface are considered. FOSMC using Gao’s reaching law is derived for inverter circuit. FOSMC is implemented at load bus to control output voltage of inverter with linear and nonlinear loads to desired values. FOSMC controls the output voltage with good voltage regulation, less steady state error of 1.32 %, settling time of 0.15 ms, good dynamic response, and convergence to origin with less chattering compared to classical SMC. FOSMC based solar based VSI is presented. The maximum power from PV array is extracted using P&O MPPT algorithm. A boost converter is used to step up input voltage of 200 V to 400 V. P-V and I-V characteristics are obtained for a typical solar cell of 2.5 kW FOSMC requires less control efforts to obtain a pure sinusoidal output voltage waveform of 230 V (rms) with output voltage THD of 0.135% well within IEEE standards. PSCAD/EMTDC v4.6 is used for simulation work\",\"PeriodicalId\":52308,\"journal\":{\"name\":\"Journal of Energy Systems\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-12-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Energy Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.30521/jes.737264\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Energy\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Energy Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.30521/jes.737264","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Energy","Score":null,"Total":0}
引用次数: 2
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Robust fractional order sliding mode control for solar based DC-AC inverter
: Fractional order sliding mode control (FOSMC) strategy for a solar based DC-AC inverter is presented in this work. First FOSMC is implemented to voltage source inverter with a fixed DC input voltage of 400V to drive a load of 2.3 kW at a power factor of 0.8 lag. Here the load voltage and current through capacitor as state variables and a linear sliding surface are considered. FOSMC using Gao’s reaching law is derived for inverter circuit. FOSMC is implemented at load bus to control output voltage of inverter with linear and nonlinear loads to desired values. FOSMC controls the output voltage with good voltage regulation, less steady state error of 1.32 %, settling time of 0.15 ms, good dynamic response, and convergence to origin with less chattering compared to classical SMC. FOSMC based solar based VSI is presented. The maximum power from PV array is extracted using P&O MPPT algorithm. A boost converter is used to step up input voltage of 200 V to 400 V. P-V and I-V characteristics are obtained for a typical solar cell of 2.5 kW FOSMC requires less control efforts to obtain a pure sinusoidal output voltage waveform of 230 V (rms) with output voltage THD of 0.135% well within IEEE standards. PSCAD/EMTDC v4.6 is used for simulation work
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Energy Systems
Journal of Energy Systems Environmental Science-Management, Monitoring, Policy and Law
CiteScore
1.60
自引率
0.00%
发文量
29
期刊最新文献
A new capacitive inductive system design for LASER-induced kilotesla magnetic field generation Efficiency analysis of fixed and axis tracking options of photovoltaic systems to be installed in a marina Cost optimization of oil type distribution transformer using multi-objective genetic algorithm Innovative approaches and modified criteria to improve a thermodynamic efficiency of trigeneration plants Identification of Vibration for Balancing in Fehn Pollux Ship with ECO Flettner Rotor
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1