A. Shaker, Ahmed Maged Farghaly, Ahmed Mohsen Hafez, M. Khattab, M. Yousry
{"title":"大隐静脉机械化学消融的安全性和有效性","authors":"A. Shaker, Ahmed Maged Farghaly, Ahmed Mohsen Hafez, M. Khattab, M. Yousry","doi":"10.5603/aa.2023.0005","DOIUrl":null,"url":null,"abstract":"Introduction: Endovenous mechano-chemical ablation of the incompetent great saphenous vein (MOCA) is a new technique that combines mechanical endothelial injury and infusion of a sclerosant agent. Material and methods: This is a prospective study was conducted on 40 patients who presented with the chronic venous disease at Kasr Al Ainy outpatient vascular surgery clinic with CEAP classification namely C2-C6. Results: A total of 40 patients were presented with great saphenous vein incompetency, the mean age was (30), 23 patients were male and 17 were female. The vein occlusion rate at one month was 93 percent and at six months was 87 percent respectively. Conclusions: Endovenous mechanochemical ablation is a safe and effective method for the management of incompetent great saphenous veins compared to open surgery.","PeriodicalId":41754,"journal":{"name":"Acta Angiologica","volume":" ","pages":""},"PeriodicalIF":0.4000,"publicationDate":"2023-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Safety and efficacy of venous mechano-chemical ablation of the great saphenous vein\",\"authors\":\"A. Shaker, Ahmed Maged Farghaly, Ahmed Mohsen Hafez, M. Khattab, M. Yousry\",\"doi\":\"10.5603/aa.2023.0005\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Introduction: Endovenous mechano-chemical ablation of the incompetent great saphenous vein (MOCA) is a new technique that combines mechanical endothelial injury and infusion of a sclerosant agent. Material and methods: This is a prospective study was conducted on 40 patients who presented with the chronic venous disease at Kasr Al Ainy outpatient vascular surgery clinic with CEAP classification namely C2-C6. Results: A total of 40 patients were presented with great saphenous vein incompetency, the mean age was (30), 23 patients were male and 17 were female. The vein occlusion rate at one month was 93 percent and at six months was 87 percent respectively. Conclusions: Endovenous mechanochemical ablation is a safe and effective method for the management of incompetent great saphenous veins compared to open surgery.\",\"PeriodicalId\":41754,\"journal\":{\"name\":\"Acta Angiologica\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.4000,\"publicationDate\":\"2023-06-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta Angiologica\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5603/aa.2023.0005\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"PERIPHERAL VASCULAR DISEASE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Angiologica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5603/aa.2023.0005","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
引用次数: 0
摘要
引言:静脉内机械化学消融治疗功能不全大隐静脉(MOCA)是一种结合机械内皮损伤和注入硬化剂的新技术。材料和方法:这是一项前瞻性研究,对Kasr Al Ainy门诊血管外科诊所的40名慢性静脉病患者进行了CEAP分类,即C2-C6。结果:大隐静脉功能不全40例,平均年龄30岁,男23例,女17例。1个月时静脉闭塞率为93%,6个月时为87%。结论:与开放手术相比,静脉内机械化学消融是一种安全有效的治疗大隐静脉功能不全的方法。
Safety and efficacy of venous mechano-chemical ablation of the great saphenous vein
Introduction: Endovenous mechano-chemical ablation of the incompetent great saphenous vein (MOCA) is a new technique that combines mechanical endothelial injury and infusion of a sclerosant agent. Material and methods: This is a prospective study was conducted on 40 patients who presented with the chronic venous disease at Kasr Al Ainy outpatient vascular surgery clinic with CEAP classification namely C2-C6. Results: A total of 40 patients were presented with great saphenous vein incompetency, the mean age was (30), 23 patients were male and 17 were female. The vein occlusion rate at one month was 93 percent and at six months was 87 percent respectively. Conclusions: Endovenous mechanochemical ablation is a safe and effective method for the management of incompetent great saphenous veins compared to open surgery.
期刊介绍:
Acta Angiologica is a bilingual (Polish/English) quarterly for angiologists and vascular surgeons as well as for other doctors interested in vascular disorders. Original papers, reviews, case reports and letters submitted by authors from different countries, concerning physiology, pathology, presentation, diagnostics and treatment of vascular system, are published. Thorough contents of Acta Angiologica provide valuable information about modern diagnostic and therapeutic issues as well as advances in basic sciences and pharmacology.