基于Global System Mobile的液化石油气汽车智能监控系统的设计与实现

IF 1.7 Q3 COMPUTER SCIENCE, INTERDISCIPLINARY APPLICATIONS International Journal of Online and Biomedical Engineering Pub Date : 2023-08-16 DOI:10.3991/ijoe.v19i11.41937
Tariq M. Salman, Hikmat N. Abdullah, Hamzah M. Marhoon, Zeyad A. Karam
{"title":"基于Global System Mobile的液化石油气汽车智能监控系统的设计与实现","authors":"Tariq M. Salman, Hikmat N. Abdullah, Hamzah M. Marhoon, Zeyad A. Karam","doi":"10.3991/ijoe.v19i11.41937","DOIUrl":null,"url":null,"abstract":"In this paper, a low-cost smart system is designed and fabricated to monitor gas leakage in LPG-based cars. The implemented system consists of three gas sensors installed in the joints of the gas pipes, gas cylinders, and injectors for the purpose of gas leak monitoring. In addition, the LM 35 temperature sensor is situated over the gas cylinder to monitor its temperature. The implemented system can provide three types of alarm: the first type sends a text message to the car owner’s phone and emits an audible alarm signal. The message reaches the service center also. The second type sends messages via Bluetooth to the user’s phone or to the smart screen on the vehicle’s dashboard, with an alert that the engine must be turned off (emergency case). The last warning sends an overheating alarm signal, utilizing a temperature sensor when the temperature of the gas cylinder exceeds 50°C to provide protection and prevent a possible explosion. In practice, it was found that gas sensors should be placed less than 5 cm from the monitored site, and the best performance at work was under 55°C. It was also found that the best performance of the GSM unit is under 55°C.","PeriodicalId":36900,"journal":{"name":"International Journal of Online and Biomedical Engineering","volume":" ","pages":""},"PeriodicalIF":1.7000,"publicationDate":"2023-08-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Design and Fabrication of a Smart Monitoring System for Liquefied Petroleum Gas-Operated Cars Based on Global System Mobile\",\"authors\":\"Tariq M. Salman, Hikmat N. Abdullah, Hamzah M. Marhoon, Zeyad A. Karam\",\"doi\":\"10.3991/ijoe.v19i11.41937\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, a low-cost smart system is designed and fabricated to monitor gas leakage in LPG-based cars. The implemented system consists of three gas sensors installed in the joints of the gas pipes, gas cylinders, and injectors for the purpose of gas leak monitoring. In addition, the LM 35 temperature sensor is situated over the gas cylinder to monitor its temperature. The implemented system can provide three types of alarm: the first type sends a text message to the car owner’s phone and emits an audible alarm signal. The message reaches the service center also. The second type sends messages via Bluetooth to the user’s phone or to the smart screen on the vehicle’s dashboard, with an alert that the engine must be turned off (emergency case). The last warning sends an overheating alarm signal, utilizing a temperature sensor when the temperature of the gas cylinder exceeds 50°C to provide protection and prevent a possible explosion. In practice, it was found that gas sensors should be placed less than 5 cm from the monitored site, and the best performance at work was under 55°C. It was also found that the best performance of the GSM unit is under 55°C.\",\"PeriodicalId\":36900,\"journal\":{\"name\":\"International Journal of Online and Biomedical Engineering\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2023-08-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Online and Biomedical Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3991/ijoe.v19i11.41937\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"COMPUTER SCIENCE, INTERDISCIPLINARY APPLICATIONS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Online and Biomedical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3991/ijoe.v19i11.41937","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"COMPUTER SCIENCE, INTERDISCIPLINARY APPLICATIONS","Score":null,"Total":0}
引用次数: 0

摘要

本文设计并制造了一个低成本的智能系统来监测液化石油气汽车的气体泄漏。实现的系统由三个气体传感器组成,安装在气体管道、气瓶和注射器的接头上,用于气体泄漏监测。此外,LM 35温度传感器位于气瓶上方,用于监测其温度。所实现的系统可以提供三种类型的警报:第一种类型向车主的手机发送短信并发出声音警报信号。信息也会到达服务中心。第二种类型通过蓝牙向用户的手机或车辆仪表板上的智能屏幕发送信息,并发出必须关闭发动机的警报(紧急情况)。最后一个警告发送过热警报信号,当气瓶温度超过50°C时,利用温度传感器提供保护并防止可能的爆炸。在实践中,人们发现气体传感器应放置在距离监测地点不到5厘米的地方,工作时的最佳性能是在55°C以下。还发现GSM单元的最佳性能是在55°C以下。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Design and Fabrication of a Smart Monitoring System for Liquefied Petroleum Gas-Operated Cars Based on Global System Mobile
In this paper, a low-cost smart system is designed and fabricated to monitor gas leakage in LPG-based cars. The implemented system consists of three gas sensors installed in the joints of the gas pipes, gas cylinders, and injectors for the purpose of gas leak monitoring. In addition, the LM 35 temperature sensor is situated over the gas cylinder to monitor its temperature. The implemented system can provide three types of alarm: the first type sends a text message to the car owner’s phone and emits an audible alarm signal. The message reaches the service center also. The second type sends messages via Bluetooth to the user’s phone or to the smart screen on the vehicle’s dashboard, with an alert that the engine must be turned off (emergency case). The last warning sends an overheating alarm signal, utilizing a temperature sensor when the temperature of the gas cylinder exceeds 50°C to provide protection and prevent a possible explosion. In practice, it was found that gas sensors should be placed less than 5 cm from the monitored site, and the best performance at work was under 55°C. It was also found that the best performance of the GSM unit is under 55°C.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.00
自引率
46.20%
发文量
143
审稿时长
12 weeks
期刊最新文献
Modification of an IMU Based System for Analyzing Hand Kinematics During Activities of Daily Living 3D Pre-Processing Algorithm for MRI Images of Different Stages of AD Segmentation of Retinal Images Using Improved Segmentation Network, MesU-Net Recent Biomaterial Developments for Bone Tissue Engineering and Potential Clinical Application: Narrative Review of the Literature Brain Tumor Localization Using N-Cut
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1