{"title":"Morin-Devin T植入黄斑带扣治疗病理性近视黄斑裂孔","authors":"A. Anand, Lalit Agarwal, N. Agrawal, A. Anand","doi":"10.35119/ASJOO.V17I1.463","DOIUrl":null,"url":null,"abstract":"Introduction: Pathological myopia is commonly associated with myopic traction maculopathy, which includes foveoschisis, foveal retinal detachment, macular hole (MH) and/or macular detachment (MD). Macular buckling is a rarely practiced extraocular surgical modality these days. The purpose of this study was to investigate the efficacy of primary buckling with Morin–Devin T implant for MD with MH and posterior staphyloma. \nCase description: A 52-year-old female presented with light perception vision in her right eye with posterior staphyloma, localized neurosensory detachment, and MH. She underwent primary macular buckling with Morin–Devin T implant. During the immediate postoperative day the wedge indentation was found misaligned to the fovea. A revision surgery was done after 2 weeks for repositioning of the macular wedge. Spectral domain optical coherence tomography confirmed indentation at the MH with resolution of subretinal fluid and hole closure. Her BCVA was 2/60 at 3 months postoperative and it remained the same even at 6 months of follow-up. \nConclusions: Primary macular buckling can be an effective procedure in eyes with MH with detachment and posterior staphyloma with or without associated foveoschisis. Morin–Devin T implant placement is a relatively simple procedure with short surgical time and excellent outcome.","PeriodicalId":39864,"journal":{"name":"Asian Journal of Ophthalmology","volume":"17 1","pages":"78-85"},"PeriodicalIF":0.0000,"publicationDate":"2020-01-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Macular buckle with Morin–Devin T implant for pathological myopia with macular hole\",\"authors\":\"A. Anand, Lalit Agarwal, N. Agrawal, A. Anand\",\"doi\":\"10.35119/ASJOO.V17I1.463\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Introduction: Pathological myopia is commonly associated with myopic traction maculopathy, which includes foveoschisis, foveal retinal detachment, macular hole (MH) and/or macular detachment (MD). Macular buckling is a rarely practiced extraocular surgical modality these days. The purpose of this study was to investigate the efficacy of primary buckling with Morin–Devin T implant for MD with MH and posterior staphyloma. \\nCase description: A 52-year-old female presented with light perception vision in her right eye with posterior staphyloma, localized neurosensory detachment, and MH. She underwent primary macular buckling with Morin–Devin T implant. During the immediate postoperative day the wedge indentation was found misaligned to the fovea. A revision surgery was done after 2 weeks for repositioning of the macular wedge. Spectral domain optical coherence tomography confirmed indentation at the MH with resolution of subretinal fluid and hole closure. Her BCVA was 2/60 at 3 months postoperative and it remained the same even at 6 months of follow-up. \\nConclusions: Primary macular buckling can be an effective procedure in eyes with MH with detachment and posterior staphyloma with or without associated foveoschisis. Morin–Devin T implant placement is a relatively simple procedure with short surgical time and excellent outcome.\",\"PeriodicalId\":39864,\"journal\":{\"name\":\"Asian Journal of Ophthalmology\",\"volume\":\"17 1\",\"pages\":\"78-85\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-01-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Asian Journal of Ophthalmology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.35119/ASJOO.V17I1.463\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Asian Journal of Ophthalmology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.35119/ASJOO.V17I1.463","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
Macular buckle with Morin–Devin T implant for pathological myopia with macular hole
Introduction: Pathological myopia is commonly associated with myopic traction maculopathy, which includes foveoschisis, foveal retinal detachment, macular hole (MH) and/or macular detachment (MD). Macular buckling is a rarely practiced extraocular surgical modality these days. The purpose of this study was to investigate the efficacy of primary buckling with Morin–Devin T implant for MD with MH and posterior staphyloma.
Case description: A 52-year-old female presented with light perception vision in her right eye with posterior staphyloma, localized neurosensory detachment, and MH. She underwent primary macular buckling with Morin–Devin T implant. During the immediate postoperative day the wedge indentation was found misaligned to the fovea. A revision surgery was done after 2 weeks for repositioning of the macular wedge. Spectral domain optical coherence tomography confirmed indentation at the MH with resolution of subretinal fluid and hole closure. Her BCVA was 2/60 at 3 months postoperative and it remained the same even at 6 months of follow-up.
Conclusions: Primary macular buckling can be an effective procedure in eyes with MH with detachment and posterior staphyloma with or without associated foveoschisis. Morin–Devin T implant placement is a relatively simple procedure with short surgical time and excellent outcome.
期刊介绍:
Asian Journal of OPHTHALMOLOGY is the official peer-reviewed journal of the South East Asia Glaucoma Interest Group (SEAGIG) and is indexed in EMBASE/Excerpta Medica. Asian Journal of OPHTHALMOLOGY is published quarterly (four [4] issues per year) by Scientific Communications International Limited. The journal is published on-line only and is distributed free of cost via the SEAGIG website.