假针刺足三里对桡动脉脉搏波的调和作用

IF 3.3 3区 医学 Q1 INTEGRATIVE & COMPLEMENTARY MEDICINE Journal of Traditional and Complementary Medicine Pub Date : 2023-11-01 DOI:10.1016/j.jtcme.2023.07.003
Kuang-Chieh Hsueh , Jenq-Haur Wang , Chi-Ying Chen , Jin-Hua Chen , George Hsiao , Yu-Cheng Kuo
{"title":"假针刺足三里对桡动脉脉搏波的调和作用","authors":"Kuang-Chieh Hsueh ,&nbsp;Jenq-Haur Wang ,&nbsp;Chi-Ying Chen ,&nbsp;Jin-Hua Chen ,&nbsp;George Hsiao ,&nbsp;Yu-Cheng Kuo","doi":"10.1016/j.jtcme.2023.07.003","DOIUrl":null,"url":null,"abstract":"<div><h3>Background and aim</h3><p>Acupuncture has been criticized as a theatrical placebo for the sham effect. Unfortunately, sham tests used in control groups in acupuncture studies have always ignored the underlying biophysical factors, including resonance involved in acupuncture points and meridians.</p></div><div><h3>Experimental procedure</h3><p>In this study, the effects of sham acupuncture at Tsu San Li (St-36) were examined by analyzing noninvasive 30-sec. recordings of the radial arterial pulses for 3 groups of patients treated with different probes (blunt, sharp, and patch) on the superficial skin of the acupuncture point. The 3 groups were then treated with the sharp probe for 3 different periods (16, 30, and 50 s). Then we compared the harmonics of the radial arterial pulse after Fourier transformation before and after the treatment.</p></div><div><h3>Results</h3><p>Our results indicated that different probes have effects similar to needle insertion at Tsu San Li. Meanwhile, the harmonic effect of the sharp probe strengthened as time increased.</p></div><div><h3>Conclusions</h3><p>This study revealed that the meridian effect of sham testing from mechanical stimulation, even from simple touch, on an acupuncture point, should not be overlooked. Thus, even simple touch can be added to electrical or laser acupuncture.</p></div>","PeriodicalId":17449,"journal":{"name":"Journal of Traditional and Complementary Medicine","volume":"13 6","pages":"Pages 568-574"},"PeriodicalIF":3.3000,"publicationDate":"2023-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Harmonic effects of sham acupuncture at Tsu San Li (St-36) in the radial pulse wave\",\"authors\":\"Kuang-Chieh Hsueh ,&nbsp;Jenq-Haur Wang ,&nbsp;Chi-Ying Chen ,&nbsp;Jin-Hua Chen ,&nbsp;George Hsiao ,&nbsp;Yu-Cheng Kuo\",\"doi\":\"10.1016/j.jtcme.2023.07.003\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background and aim</h3><p>Acupuncture has been criticized as a theatrical placebo for the sham effect. Unfortunately, sham tests used in control groups in acupuncture studies have always ignored the underlying biophysical factors, including resonance involved in acupuncture points and meridians.</p></div><div><h3>Experimental procedure</h3><p>In this study, the effects of sham acupuncture at Tsu San Li (St-36) were examined by analyzing noninvasive 30-sec. recordings of the radial arterial pulses for 3 groups of patients treated with different probes (blunt, sharp, and patch) on the superficial skin of the acupuncture point. The 3 groups were then treated with the sharp probe for 3 different periods (16, 30, and 50 s). Then we compared the harmonics of the radial arterial pulse after Fourier transformation before and after the treatment.</p></div><div><h3>Results</h3><p>Our results indicated that different probes have effects similar to needle insertion at Tsu San Li. Meanwhile, the harmonic effect of the sharp probe strengthened as time increased.</p></div><div><h3>Conclusions</h3><p>This study revealed that the meridian effect of sham testing from mechanical stimulation, even from simple touch, on an acupuncture point, should not be overlooked. Thus, even simple touch can be added to electrical or laser acupuncture.</p></div>\",\"PeriodicalId\":17449,\"journal\":{\"name\":\"Journal of Traditional and Complementary Medicine\",\"volume\":\"13 6\",\"pages\":\"Pages 568-574\"},\"PeriodicalIF\":3.3000,\"publicationDate\":\"2023-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Traditional and Complementary Medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2225411023000780\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"INTEGRATIVE & COMPLEMENTARY MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Traditional and Complementary Medicine","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2225411023000780","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"INTEGRATIVE & COMPLEMENTARY MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

背景和目的针刺因其虚假效果而被批评为戏剧安慰剂。不幸的是,在针灸研究中用于对照组的假试验总是忽略了潜在的生物物理因素,包括涉及穴位和经络的共振。实验方法本研究通过无创30秒分析,观察假针刺足三里(St-36)的作用。三组患者在穴位浅表皮肤上使用不同探针(钝、尖、贴)记录桡动脉脉搏。三组患者分别在治疗前、治疗后的16、30、50 s 3个不同时段进行尖探针治疗,比较治疗前后桡动脉脉冲傅立叶变换后的谐波。结果不同探针对足三里的刺入效果相似。同时,尖探针的谐波效应随着时间的增加而增强。结论本研究揭示了机械刺激(甚至是简单的触摸)对穴位的经络效应不应被忽视。因此,即使是简单的触摸也可以添加到电或激光针灸中。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Harmonic effects of sham acupuncture at Tsu San Li (St-36) in the radial pulse wave

Background and aim

Acupuncture has been criticized as a theatrical placebo for the sham effect. Unfortunately, sham tests used in control groups in acupuncture studies have always ignored the underlying biophysical factors, including resonance involved in acupuncture points and meridians.

Experimental procedure

In this study, the effects of sham acupuncture at Tsu San Li (St-36) were examined by analyzing noninvasive 30-sec. recordings of the radial arterial pulses for 3 groups of patients treated with different probes (blunt, sharp, and patch) on the superficial skin of the acupuncture point. The 3 groups were then treated with the sharp probe for 3 different periods (16, 30, and 50 s). Then we compared the harmonics of the radial arterial pulse after Fourier transformation before and after the treatment.

Results

Our results indicated that different probes have effects similar to needle insertion at Tsu San Li. Meanwhile, the harmonic effect of the sharp probe strengthened as time increased.

Conclusions

This study revealed that the meridian effect of sham testing from mechanical stimulation, even from simple touch, on an acupuncture point, should not be overlooked. Thus, even simple touch can be added to electrical or laser acupuncture.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Traditional and Complementary Medicine
Journal of Traditional and Complementary Medicine Medicine-Complementary and Alternative Medicine
CiteScore
9.30
自引率
6.70%
发文量
78
审稿时长
66 days
期刊介绍: eJTCM is committed to publish research providing the biological and clinical grounds for using Traditional and Complementary Medical treatments as well as studies that demonstrate the pathophysiological and molecular/biochemical bases supporting the effectiveness of such treatments. Review articles are by invitation only. eJTCM is receiving an increasing amount of submission, and we need to adopt more stringent criteria to select the articles that can be considered for peer review. Note that eJTCM is striving to increase the quality and medical relevance of the publications.
期刊最新文献
Red rice bran aqueous extract ameliorate diabetic status by inhibiting intestinal glucose transport in high fat diet/STZ-induced diabetic rats The chemical composition of Diwu YangGan capsule and its potential inhibitory roles on hepatocellular carcinoma by microarray-based transcriptomics The therapeutic effect and metabolic mechanism analysis of Guilingji on idiopathic oligo-asthenoteratozoospermia Electroacupuncture improves articular microcirculation and attenuates cartilage hypoxia in a male rabbit model of knee osteoarthritis Neuroprotective effects of Tradescantia spathacea tea bioactives in Parkinson’s disease: In vivo proof-of-concept
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1