分子印迹过氧化聚吡咯包覆玻碳电极选择性电化学测定依托泊苷

IF 2.3 Q3 ELECTROCHEMISTRY International journal of electrochemistry Pub Date : 2019-01-02 DOI:10.1155/2019/5394235
H. Hrichi, L. Monser, N. Adhoum
{"title":"分子印迹过氧化聚吡咯包覆玻碳电极选择性电化学测定依托泊苷","authors":"H. Hrichi, L. Monser, N. Adhoum","doi":"10.1155/2019/5394235","DOIUrl":null,"url":null,"abstract":"A simple and efficient new electrochemical sensor based on molecularly imprinted polymer has been developed for selective detection of an anticancer agent Etoposide (ETP). The sensor was prepared by electropolymerization via cyclic voltammetry (CV) of pyrrole onto a glassy carbon electrode (GCE) in the presence of ETP molecules. The extraction of ETP molecules embedded in the polymeric matrix was carried out by overoxidation in sodium hydroxide medium using CV. Various important parameters affecting the performance of the imprinted film (MIP) coated sensor were studied and optimized using differential pulse voltammetry (DPV). Under optimal conditions, the sensor response exhibited a linear dependence on ETP concentration (R2= 0.999) over the range 5.0×10−7M – 1.0×10−5M with a LOD (3σ/m) of 2.8×10−9M. The precision (% RSD, n=6) of the proposed sensor for intra- and interdays was found to be 0.84 and 2.46%, respectively. The selectivity of MIP/GCE sensor toward ETP was investigated in the presence of different interfering molecules including excipients and ETP metabolites. The developed sensor showed great recognition ability toward ETP and was successfully applied for its determination in injectable dosage forms and biological human fluids.","PeriodicalId":13933,"journal":{"name":"International journal of electrochemistry","volume":" ","pages":""},"PeriodicalIF":2.3000,"publicationDate":"2019-01-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1155/2019/5394235","citationCount":"10","resultStr":"{\"title\":\"Selective Electrochemical Determination of Etoposide Using a Molecularly Imprinted Overoxidized Polypyrrole Coated Glassy Carbon Electrode\",\"authors\":\"H. Hrichi, L. Monser, N. Adhoum\",\"doi\":\"10.1155/2019/5394235\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A simple and efficient new electrochemical sensor based on molecularly imprinted polymer has been developed for selective detection of an anticancer agent Etoposide (ETP). The sensor was prepared by electropolymerization via cyclic voltammetry (CV) of pyrrole onto a glassy carbon electrode (GCE) in the presence of ETP molecules. The extraction of ETP molecules embedded in the polymeric matrix was carried out by overoxidation in sodium hydroxide medium using CV. Various important parameters affecting the performance of the imprinted film (MIP) coated sensor were studied and optimized using differential pulse voltammetry (DPV). Under optimal conditions, the sensor response exhibited a linear dependence on ETP concentration (R2= 0.999) over the range 5.0×10−7M – 1.0×10−5M with a LOD (3σ/m) of 2.8×10−9M. The precision (% RSD, n=6) of the proposed sensor for intra- and interdays was found to be 0.84 and 2.46%, respectively. The selectivity of MIP/GCE sensor toward ETP was investigated in the presence of different interfering molecules including excipients and ETP metabolites. The developed sensor showed great recognition ability toward ETP and was successfully applied for its determination in injectable dosage forms and biological human fluids.\",\"PeriodicalId\":13933,\"journal\":{\"name\":\"International journal of electrochemistry\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2019-01-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1155/2019/5394235\",\"citationCount\":\"10\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International journal of electrochemistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1155/2019/5394235\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ELECTROCHEMISTRY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International journal of electrochemistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2019/5394235","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ELECTROCHEMISTRY","Score":null,"Total":0}
引用次数: 10

摘要

开发了一种基于分子印迹聚合物的新型电化学传感器,用于抗癌剂依托泊苷(ETP)的选择性检测。在ETP分子存在下,通过吡咯在玻碳电极(GCE)上的循环伏安法(CV)电聚合制备传感器。利用CV在氢氧化钠介质中过氧化法提取聚合物基体中嵌入的ETP分子。利用微分脉冲伏安法(DPV)研究并优化了影响印迹膜(MIP)涂层传感器性能的各种重要参数。在最佳条件下,传感器响应在5.0×10−7M–1.0×10−5M范围内与ETP浓度呈线性关系(R2=0.99),LOD(3σ/m)为2.8×10−9M。所提出的传感器日内和日间的精密度(%RSD,n=6)分别为0.84%和2.46%。在赋形剂和ETP代谢产物等不同干扰分子存在的情况下,研究了MIP/GCE传感器对ETP的选择性。所开发的传感器对ETP具有很强的识别能力,并成功应用于注射剂型和生物体液中ETP的测定。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Selective Electrochemical Determination of Etoposide Using a Molecularly Imprinted Overoxidized Polypyrrole Coated Glassy Carbon Electrode
A simple and efficient new electrochemical sensor based on molecularly imprinted polymer has been developed for selective detection of an anticancer agent Etoposide (ETP). The sensor was prepared by electropolymerization via cyclic voltammetry (CV) of pyrrole onto a glassy carbon electrode (GCE) in the presence of ETP molecules. The extraction of ETP molecules embedded in the polymeric matrix was carried out by overoxidation in sodium hydroxide medium using CV. Various important parameters affecting the performance of the imprinted film (MIP) coated sensor were studied and optimized using differential pulse voltammetry (DPV). Under optimal conditions, the sensor response exhibited a linear dependence on ETP concentration (R2= 0.999) over the range 5.0×10−7M – 1.0×10−5M with a LOD (3σ/m) of 2.8×10−9M. The precision (% RSD, n=6) of the proposed sensor for intra- and interdays was found to be 0.84 and 2.46%, respectively. The selectivity of MIP/GCE sensor toward ETP was investigated in the presence of different interfering molecules including excipients and ETP metabolites. The developed sensor showed great recognition ability toward ETP and was successfully applied for its determination in injectable dosage forms and biological human fluids.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
2
审稿时长
7 weeks
期刊最新文献
Effect of Surface Composition on Electrochemical Oxidation Reaction of Carbon Monoxide and Ethanol of PtxRh1−x Solid Solution Electrodes Development and Characterization of a New Solid Polymer Electrolyte for Supercapacitor Device Size-Dependent Chlorinated Nitrogen-Doped Carbon Nanotubes: Their Use as Electrochemical Detectors for Catechol and Resorcinol Enabling the Electrochemical Performance of Maricite-NaMnPO4 and Maricite-NaFePO4 Cathode Materials in Sodium-Ion Batteries Electrooxidation and Development of a Highly Sensitive Electrochemical Probe for Trace Determination of the Steroid 11-Desoxycorticosterone Drug Residues in Water
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1