用PHITS代码与30MeV CYCLOTRON中子进行硼中子捕获治疗甲状腺癌的剂量分析

IF 0.6 Q3 ENGINEERING, MULTIDISCIPLINARY Jurnal Teknologi-Sciences & Engineering Pub Date : 2023-08-21 DOI:10.11113/jurnalteknologi.v85.19454
B. Bilalodin, Wihantoro Wihantoro, A. Haryadi, F. Abdullatif
{"title":"用PHITS代码与30MeV CYCLOTRON中子进行硼中子捕获治疗甲状腺癌的剂量分析","authors":"B. Bilalodin, Wihantoro Wihantoro, A. Haryadi, F. Abdullatif","doi":"10.11113/jurnalteknologi.v85.19454","DOIUrl":null,"url":null,"abstract":"The dosimetry analysis of Boron Neutron Capture Therapy (BNCT) on thyroid cancer using the Particle and Heavy Ion Transport Code System (PHITS) has been carried out. The purpose of research was to determine the received dose rate and the irradiation time required for thyroid cancer therapy using the BNCT method. The geometry of thyroid model is based on MIRD phantom with cancer cells located in the center of the thyroid. The phantom was irradiated using a neutron source from DLBSA based 30 MeV cyclotron.  Simulations were carried out at boron concentrations of (10, 20, 30, 40, 50, 60, and 70) mg/g tissue. Simulation results show that the boron concentration increases with dose rate. The highest dose rate was obtained in the Gross Target Volume (GTV) of 1.590 x 10-2 Gy/s using a boron concentration of 70 mg/g tissue. The effective time for cancer therapy was calculated based on the highest dose rate obtained at 57 minutes.","PeriodicalId":47541,"journal":{"name":"Jurnal Teknologi-Sciences & Engineering","volume":" ","pages":""},"PeriodicalIF":0.6000,"publicationDate":"2023-08-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"DOSIMETRY ANALYSIS OF BORON NEUTRON CAPTURE THERAPY (BNCT) ON THYROID CANCER USING PHITS CODE WITH NEUTRON FROM 30 MeV CYCLOTRON\",\"authors\":\"B. Bilalodin, Wihantoro Wihantoro, A. Haryadi, F. Abdullatif\",\"doi\":\"10.11113/jurnalteknologi.v85.19454\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The dosimetry analysis of Boron Neutron Capture Therapy (BNCT) on thyroid cancer using the Particle and Heavy Ion Transport Code System (PHITS) has been carried out. The purpose of research was to determine the received dose rate and the irradiation time required for thyroid cancer therapy using the BNCT method. The geometry of thyroid model is based on MIRD phantom with cancer cells located in the center of the thyroid. The phantom was irradiated using a neutron source from DLBSA based 30 MeV cyclotron.  Simulations were carried out at boron concentrations of (10, 20, 30, 40, 50, 60, and 70) mg/g tissue. Simulation results show that the boron concentration increases with dose rate. The highest dose rate was obtained in the Gross Target Volume (GTV) of 1.590 x 10-2 Gy/s using a boron concentration of 70 mg/g tissue. The effective time for cancer therapy was calculated based on the highest dose rate obtained at 57 minutes.\",\"PeriodicalId\":47541,\"journal\":{\"name\":\"Jurnal Teknologi-Sciences & Engineering\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.6000,\"publicationDate\":\"2023-08-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Jurnal Teknologi-Sciences & Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.11113/jurnalteknologi.v85.19454\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jurnal Teknologi-Sciences & Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11113/jurnalteknologi.v85.19454","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

利用粒子和重离子传输编码系统(PHITS)对癌症的硼中子捕获治疗(BNCT)进行了剂量测定分析。本研究的目的是用BNCT方法确定甲状腺癌症治疗所需的剂量率和照射时间。甲状腺模型的几何形状基于MIRD体模,癌症细胞位于甲状腺中心。使用来自基于DLBSA的30MeV回旋加速器的中子源照射体模。模拟是在硼浓度为(10、20、30、40、50、60和70)mg/g组织下进行的。模拟结果表明,硼浓度随剂量率的增加而增加。在硼浓度为70 mg/g组织的情况下,在1.590 x 10-2 Gy/s的总靶体积(GTV)下获得了最高剂量率。癌症治疗的有效时间是根据57分钟时获得的最高剂量率计算的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
DOSIMETRY ANALYSIS OF BORON NEUTRON CAPTURE THERAPY (BNCT) ON THYROID CANCER USING PHITS CODE WITH NEUTRON FROM 30 MeV CYCLOTRON
The dosimetry analysis of Boron Neutron Capture Therapy (BNCT) on thyroid cancer using the Particle and Heavy Ion Transport Code System (PHITS) has been carried out. The purpose of research was to determine the received dose rate and the irradiation time required for thyroid cancer therapy using the BNCT method. The geometry of thyroid model is based on MIRD phantom with cancer cells located in the center of the thyroid. The phantom was irradiated using a neutron source from DLBSA based 30 MeV cyclotron.  Simulations were carried out at boron concentrations of (10, 20, 30, 40, 50, 60, and 70) mg/g tissue. Simulation results show that the boron concentration increases with dose rate. The highest dose rate was obtained in the Gross Target Volume (GTV) of 1.590 x 10-2 Gy/s using a boron concentration of 70 mg/g tissue. The effective time for cancer therapy was calculated based on the highest dose rate obtained at 57 minutes.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Jurnal Teknologi-Sciences & Engineering
Jurnal Teknologi-Sciences & Engineering ENGINEERING, MULTIDISCIPLINARY-
CiteScore
1.30
自引率
0.00%
发文量
96
期刊最新文献
A RECENT REVIEW OF THE SANDWICH-STRUCTURED COMPOSITE METAMATERIALS: STATIC AND DYNAMIC ANALYSIS ANALYSIS OF ACTIVE SECONDARY SUSPENSION WITH MODIFIED SKYHOOK CONTROLLER TO IMPROVE RIDE PERFORMANCE OF RAILWAY VEHICLE DESIGNING THE TECHNOLOGY FOR TURBIDITY SENSOR-BASED AUTOMATIC RIVER SEDIMENTATION MEASUREMENT CFD SIMULATION AND VALIDATION FOR MIXING VENTILATION SCALED-DOWN EMPTY AIRCRAFT CABIN USING OPENFOAM COMPARATIVE STUDY OF CONFIGURATIONS FOR PHOTOVOLTAIC-THERMOELECTRIC GENERATOR COGENERATION SYSTEM
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1