{"title":"静电纺丝合成四氧化钴-石墨烯复合膜及修饰玻碳电极测定氧氟沙星","authors":"Yuxin Zhang, Yong Li, Pengchong Yin, Yongxing Hao, Ruizhu Zhang","doi":"10.14447/jnmes.v25i3.a09","DOIUrl":null,"url":null,"abstract":"The purpose of this study was to determinate ofloxacin, the approach of electrospinning and electrochemical was adopted, metal oxide cobalt tetroxide (Co3O4)/graphene (GR) nanomaterials were electrodeposited on the surface of glassy carbon electrode, then prepared a new type of nanocomposite electrode (Co3O4/GR/GCE), it was successfully used to measure ofloxacin. The experiments show that the surface morphology of the modified electrode was characterized by scanning electron microscopy, and the Co3O4 nanoparticles and GR could be well modified on the surface of the glassy carbon electrode. The determination conditions of ofloxacin were optimized by the differential pulse voltametry (DPV). Under the optimal conditions, the linear relationship ranged from 0.45 to 170 μM, and the minimum detection limit was 0.16 μM (S/N = 3). Moreover, the recovery rate in the actual drug was good, and the relative standard deviations were all less than 5%. The impacts of the obtained results indicate that the modified electrode has good electrocatalytic performance for ofloxacin, and has good repeatability and practicability, and can significantly improve the detection sensitivity.","PeriodicalId":16447,"journal":{"name":"Journal of New Materials For Electrochemical Systems","volume":" ","pages":""},"PeriodicalIF":0.7000,"publicationDate":"2022-08-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Synthesized Cobalt Tetroxide-Graphene Composite Film by Electrospinning and Modified Glassy Carbon Electrode for Ofloxacin Determination\",\"authors\":\"Yuxin Zhang, Yong Li, Pengchong Yin, Yongxing Hao, Ruizhu Zhang\",\"doi\":\"10.14447/jnmes.v25i3.a09\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The purpose of this study was to determinate ofloxacin, the approach of electrospinning and electrochemical was adopted, metal oxide cobalt tetroxide (Co3O4)/graphene (GR) nanomaterials were electrodeposited on the surface of glassy carbon electrode, then prepared a new type of nanocomposite electrode (Co3O4/GR/GCE), it was successfully used to measure ofloxacin. The experiments show that the surface morphology of the modified electrode was characterized by scanning electron microscopy, and the Co3O4 nanoparticles and GR could be well modified on the surface of the glassy carbon electrode. The determination conditions of ofloxacin were optimized by the differential pulse voltametry (DPV). Under the optimal conditions, the linear relationship ranged from 0.45 to 170 μM, and the minimum detection limit was 0.16 μM (S/N = 3). Moreover, the recovery rate in the actual drug was good, and the relative standard deviations were all less than 5%. The impacts of the obtained results indicate that the modified electrode has good electrocatalytic performance for ofloxacin, and has good repeatability and practicability, and can significantly improve the detection sensitivity.\",\"PeriodicalId\":16447,\"journal\":{\"name\":\"Journal of New Materials For Electrochemical Systems\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.7000,\"publicationDate\":\"2022-08-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of New Materials For Electrochemical Systems\",\"FirstCategoryId\":\"88\",\"ListUrlMain\":\"https://doi.org/10.14447/jnmes.v25i3.a09\",\"RegionNum\":4,\"RegionCategory\":\"材料科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ELECTROCHEMISTRY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of New Materials For Electrochemical Systems","FirstCategoryId":"88","ListUrlMain":"https://doi.org/10.14447/jnmes.v25i3.a09","RegionNum":4,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ELECTROCHEMISTRY","Score":null,"Total":0}
引用次数: 0

摘要

本研究采用静电纺丝和电化学方法,在玻碳电极表面电沉积金属氧化物四氧化钴(Co3O4)/石墨烯(GR)纳米材料,制备了一种新型的纳米复合电极(Co3O4/GR/GCE),并成功地用于测定氧氟沙星。实验表明,通过扫描电子显微镜对修饰电极的表面形貌进行了表征,Co3O4纳米粒子和GR可以很好地修饰在玻碳电极表面。采用差示脉冲伏安法(DPV)对氧氟沙星的测定条件进行了优化。在最佳条件下,线性关系为0.45~170μM,最低检测限为0.16μM(S/N=3)。此外,在实际药物中的回收率良好,相对标准偏差均小于5%。结果表明,该修饰电极对氧氟沙星具有良好的电催化性能,具有良好的重复性和实用性,能显著提高检测灵敏度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Synthesized Cobalt Tetroxide-Graphene Composite Film by Electrospinning and Modified Glassy Carbon Electrode for Ofloxacin Determination
The purpose of this study was to determinate ofloxacin, the approach of electrospinning and electrochemical was adopted, metal oxide cobalt tetroxide (Co3O4)/graphene (GR) nanomaterials were electrodeposited on the surface of glassy carbon electrode, then prepared a new type of nanocomposite electrode (Co3O4/GR/GCE), it was successfully used to measure ofloxacin. The experiments show that the surface morphology of the modified electrode was characterized by scanning electron microscopy, and the Co3O4 nanoparticles and GR could be well modified on the surface of the glassy carbon electrode. The determination conditions of ofloxacin were optimized by the differential pulse voltametry (DPV). Under the optimal conditions, the linear relationship ranged from 0.45 to 170 μM, and the minimum detection limit was 0.16 μM (S/N = 3). Moreover, the recovery rate in the actual drug was good, and the relative standard deviations were all less than 5%. The impacts of the obtained results indicate that the modified electrode has good electrocatalytic performance for ofloxacin, and has good repeatability and practicability, and can significantly improve the detection sensitivity.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of New Materials For Electrochemical Systems
Journal of New Materials For Electrochemical Systems ELECTROCHEMISTRY-MATERIALS SCIENCE, MULTIDISCIPLINARY
CiteScore
1.90
自引率
0.00%
发文量
33
审稿时长
>12 weeks
期刊介绍: This international Journal is intended for the publication of original work, both analytical and experimental, and of reviews and commercial aspects related to the field of New Materials for Electrochemical Systems. The emphasis will be on research both of a fundamental and an applied nature in various aspects of the development of new materials in electrochemical systems.
期刊最新文献
Effect of Ceramic Coated Tool on Stray Cut in Electrochemical Micromachining Hybrid Optimization Algorithms for Maximum Power Point Tracking based Incremental Conductance Techniques with Solar Cell Synthesis of Graphene Oxide Coating on ZnCo2S4 Using Hydrothermal Method for Electrochemical Capacitors Applications Harmonics Reduction and Balanced Transition in Hybrid Renewable Energy Sources in a Micro Grid Power System Tuning the Particle Size Distribution at Cathode for Enhanced Li-Ion Battery Performance
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1