主动移除前段移位地塞米松植入物(Ozurdex®)

Jozef Adelson M. Depla, M. Veckeneer, I. Bleyen
{"title":"主动移除前段移位地塞米松植入物(Ozurdex®)","authors":"Jozef Adelson M. Depla, M. Veckeneer, I. Bleyen","doi":"10.3205/oc000195","DOIUrl":null,"url":null,"abstract":"Background: Ozurdex® (Allergan plc., Dublin, Ireland) is an intravitreal sustained-release dexamethasone (DEX) implant. The implant has been reported to migrate into the anterior chamber, potentially causing corneal decompensation. Prompt removal or relocation in the vitreous cavity is advised but troublesome due to its fragility. Several techniques exist, but elaborate setup and specialized surgical skills that are required may cause delay in treatment. We report a novel technique that avoids these shortcomings. Case presentation: A 59-year-old woman presented to the emergency department with visual loss due to an anterior chamber-migrated DEX implant and corneal edema. Using an ophthalmic viscosurgical device (OVD) and a bent 19-gauge needle, the implant has promptly been removed in a one-minute procedure under topical anesthesia. Conclusion: Aspirating an anterior chamber-migrated DEX implant using a 19-gauge bent needle is a cost-effective, time-efficient and safe technique, not requiring specialized surgical skills.","PeriodicalId":73178,"journal":{"name":"GMS ophthalmology cases","volume":"12 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-12-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Active removal of anterior segment-migrated dexamethasone implant (Ozurdex®)\",\"authors\":\"Jozef Adelson M. Depla, M. Veckeneer, I. Bleyen\",\"doi\":\"10.3205/oc000195\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: Ozurdex® (Allergan plc., Dublin, Ireland) is an intravitreal sustained-release dexamethasone (DEX) implant. The implant has been reported to migrate into the anterior chamber, potentially causing corneal decompensation. Prompt removal or relocation in the vitreous cavity is advised but troublesome due to its fragility. Several techniques exist, but elaborate setup and specialized surgical skills that are required may cause delay in treatment. We report a novel technique that avoids these shortcomings. Case presentation: A 59-year-old woman presented to the emergency department with visual loss due to an anterior chamber-migrated DEX implant and corneal edema. Using an ophthalmic viscosurgical device (OVD) and a bent 19-gauge needle, the implant has promptly been removed in a one-minute procedure under topical anesthesia. Conclusion: Aspirating an anterior chamber-migrated DEX implant using a 19-gauge bent needle is a cost-effective, time-efficient and safe technique, not requiring specialized surgical skills.\",\"PeriodicalId\":73178,\"journal\":{\"name\":\"GMS ophthalmology cases\",\"volume\":\"12 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-12-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"GMS ophthalmology cases\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3205/oc000195\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"GMS ophthalmology cases","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3205/oc000195","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

背景:Ozurdex®(Allergan plc,都柏林,爱尔兰)是一种玻璃体内缓释地塞米松(DEX)植入物。据报道,植入物会迁移到前房,可能导致角膜失代偿。建议在玻璃体腔内及时取出或重新定位,但由于其脆弱性,这很麻烦。有几种技术存在,但所需的精心设置和专业手术技能可能会导致治疗延迟。我们报告了一种避免这些缺点的新颖技术。病例介绍:一名59岁的女性因前房移位的DEX植入物和角膜水肿导致视力下降,被送往急诊科。使用眼科粘性外科器械(OVD)和弯曲的19号针头,在局部麻醉下,在一分钟的手术中迅速取出植入物。结论:使用19号弯针抽吸前房移位DEX植入物是一种成本效益高、时间有效且安全的技术,不需要专业的手术技能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Active removal of anterior segment-migrated dexamethasone implant (Ozurdex®)
Background: Ozurdex® (Allergan plc., Dublin, Ireland) is an intravitreal sustained-release dexamethasone (DEX) implant. The implant has been reported to migrate into the anterior chamber, potentially causing corneal decompensation. Prompt removal or relocation in the vitreous cavity is advised but troublesome due to its fragility. Several techniques exist, but elaborate setup and specialized surgical skills that are required may cause delay in treatment. We report a novel technique that avoids these shortcomings. Case presentation: A 59-year-old woman presented to the emergency department with visual loss due to an anterior chamber-migrated DEX implant and corneal edema. Using an ophthalmic viscosurgical device (OVD) and a bent 19-gauge needle, the implant has promptly been removed in a one-minute procedure under topical anesthesia. Conclusion: Aspirating an anterior chamber-migrated DEX implant using a 19-gauge bent needle is a cost-effective, time-efficient and safe technique, not requiring specialized surgical skills.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
审稿时长
6 weeks
期刊最新文献
Cancer-associated retinopathy secondary to gallbladder carcinoma. Diffuse preretinal infiltrates in a patient with orbital atypical T-cell lymphoproliferative infiltration masquerading posterior uveitis. Epithelial downgrowth masquerading as granulomatous anterior and intermediate uveitis with histopathologic evidence of 5-FU treatment. Pseudophakic corneal edema caused by Descemet membrane detachment using high-resolution swept-source OCT imaging. Bilateral reversible optic neuropathy as the first sign of Waldenström macroglobulinema.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1