新型三维CAD/CAM钛合金固定器的数字化结构、生产和口内位置精度评估。

IF 1.3 4区 医学 Q3 DENTISTRY, ORAL SURGERY & MEDICINE Journal of Orofacial Orthopedics-Fortschritte Der Kieferorthopadie Pub Date : 2023-11-01 Epub Date: 2022-03-31 DOI:10.1007/s00056-022-00393-8
S Koller, R B Craveiro, C Niederau, T L Pollak, I Knaup, M Wolf
{"title":"新型三维CAD/CAM钛合金固定器的数字化结构、生产和口内位置精度评估。","authors":"S Koller,&nbsp;R B Craveiro,&nbsp;C Niederau,&nbsp;T L Pollak,&nbsp;I Knaup,&nbsp;M Wolf","doi":"10.1007/s00056-022-00393-8","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>New opportunities have arisen to manufacture three-dimensional computer-aided design/computer-aided manufacturing (3D CAD/CAM) retainers from titanium blocks by digital cutting technology. These novel technologies need to fulfill requirements regarding digital planning and position accuracy. The aim of the present study was to investigate the digital construction, the CAD/CAM production and the intraoral positioning accuracy of custom-manufactured novel 3D CAD/CAM titanium retainers.</p><p><strong>Materials and methods: </strong>A total of 37 prime4me® RETAIN3R (Dentaurum, Ispringen, Germany) retainers were inserted to stabilize the upper anterior front teeth. Following insertion, an intraoral scan was used to record the position. The intraoral position was compared to the virtual setup using 3D superimposition software. Measurement points were evaluated in all three dimensions (horizontal, sagittal and vertical planes). Data were analyzed using Kruskal-Wallis test followed by Dunn's multiple comparison test.</p><p><strong>Results: </strong>A total of 185 measurements were performed. The horizontal plane and the sagittal plane demonstrated a high level of positioning accuracy between the planned and the intraoral position. Statistically significant deviations between the preceding virtual setup and the intraoral situation were observed in the vertical dimension. Within the retainer, the intraoral positioning accuracy decreased for the measurement points in the direction of the distal retainer segment.</p><p><strong>Conclusion: </strong>Based on the results, the present study shows a high level of congruence between the 3D virtually planning and the final intraoral position of the fabricated novel 3D CAD/CAM titanium retainers.</p>","PeriodicalId":54776,"journal":{"name":"Journal of Orofacial Orthopedics-Fortschritte Der Kieferorthopadie","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2023-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10587025/pdf/","citationCount":"1","resultStr":"{\"title\":\"Evaluation of digital construction, production and intraoral position accuracy of novel 3D CAD/CAM titanium retainers.\",\"authors\":\"S Koller,&nbsp;R B Craveiro,&nbsp;C Niederau,&nbsp;T L Pollak,&nbsp;I Knaup,&nbsp;M Wolf\",\"doi\":\"10.1007/s00056-022-00393-8\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>New opportunities have arisen to manufacture three-dimensional computer-aided design/computer-aided manufacturing (3D CAD/CAM) retainers from titanium blocks by digital cutting technology. These novel technologies need to fulfill requirements regarding digital planning and position accuracy. The aim of the present study was to investigate the digital construction, the CAD/CAM production and the intraoral positioning accuracy of custom-manufactured novel 3D CAD/CAM titanium retainers.</p><p><strong>Materials and methods: </strong>A total of 37 prime4me® RETAIN3R (Dentaurum, Ispringen, Germany) retainers were inserted to stabilize the upper anterior front teeth. Following insertion, an intraoral scan was used to record the position. The intraoral position was compared to the virtual setup using 3D superimposition software. Measurement points were evaluated in all three dimensions (horizontal, sagittal and vertical planes). Data were analyzed using Kruskal-Wallis test followed by Dunn's multiple comparison test.</p><p><strong>Results: </strong>A total of 185 measurements were performed. The horizontal plane and the sagittal plane demonstrated a high level of positioning accuracy between the planned and the intraoral position. Statistically significant deviations between the preceding virtual setup and the intraoral situation were observed in the vertical dimension. Within the retainer, the intraoral positioning accuracy decreased for the measurement points in the direction of the distal retainer segment.</p><p><strong>Conclusion: </strong>Based on the results, the present study shows a high level of congruence between the 3D virtually planning and the final intraoral position of the fabricated novel 3D CAD/CAM titanium retainers.</p>\",\"PeriodicalId\":54776,\"journal\":{\"name\":\"Journal of Orofacial Orthopedics-Fortschritte Der Kieferorthopadie\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2023-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10587025/pdf/\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Orofacial Orthopedics-Fortschritte Der Kieferorthopadie\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s00056-022-00393-8\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2022/3/31 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Orofacial Orthopedics-Fortschritte Der Kieferorthopadie","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00056-022-00393-8","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/3/31 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 1

摘要

目标:通过数字切割技术,用钛块制造三维计算机辅助设计/计算机辅助制造(3DCAD/CAM)保持器出现了新的机会。这些新技术需要满足数字规划和定位精度方面的要求。本研究的目的是研究定制的新型三维CAD/CAM钛保持器的数字化结构、CAD/CAM生产和口内定位精度。材料和方法:共插入37个prime4me®RETAIN3R(Dentaurum,Ispringen,Germany)固位器,以稳定上前门牙。插入后,使用口内扫描记录位置。使用3D叠加软件将口内位置与虚拟设置进行比较。在所有三个维度(水平面、矢状面和垂直面)上评估测量点。使用Kruskal-Wallis检验和Dunn多重比较检验对数据进行分析。结果:共进行了185次测量。水平面和矢状面显示了计划位置和口内位置之间的高水平定位精度。在垂直维度上观察到之前的虚拟设置和口内情况之间存在统计学上的显著偏差。在固定器内,在远端固定器段方向上的测量点的口内定位精度降低。结论:基于这些结果,本研究表明,制造的新型三维CAD/CAM钛保持器的三维虚拟规划和最终口内位置之间具有高度一致性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Evaluation of digital construction, production and intraoral position accuracy of novel 3D CAD/CAM titanium retainers.

Objectives: New opportunities have arisen to manufacture three-dimensional computer-aided design/computer-aided manufacturing (3D CAD/CAM) retainers from titanium blocks by digital cutting technology. These novel technologies need to fulfill requirements regarding digital planning and position accuracy. The aim of the present study was to investigate the digital construction, the CAD/CAM production and the intraoral positioning accuracy of custom-manufactured novel 3D CAD/CAM titanium retainers.

Materials and methods: A total of 37 prime4me® RETAIN3R (Dentaurum, Ispringen, Germany) retainers were inserted to stabilize the upper anterior front teeth. Following insertion, an intraoral scan was used to record the position. The intraoral position was compared to the virtual setup using 3D superimposition software. Measurement points were evaluated in all three dimensions (horizontal, sagittal and vertical planes). Data were analyzed using Kruskal-Wallis test followed by Dunn's multiple comparison test.

Results: A total of 185 measurements were performed. The horizontal plane and the sagittal plane demonstrated a high level of positioning accuracy between the planned and the intraoral position. Statistically significant deviations between the preceding virtual setup and the intraoral situation were observed in the vertical dimension. Within the retainer, the intraoral positioning accuracy decreased for the measurement points in the direction of the distal retainer segment.

Conclusion: Based on the results, the present study shows a high level of congruence between the 3D virtually planning and the final intraoral position of the fabricated novel 3D CAD/CAM titanium retainers.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.90
自引率
0.00%
发文量
64
审稿时长
>12 weeks
期刊介绍: The Journal of Orofacial Orthopedics provides orthodontists and dentists who are also actively interested in orthodontics, whether in university clinics or private practice, with highly authoritative and up-to-date information based on experimental and clinical research. The journal is one of the leading publications for the promulgation of the results of original work both in the areas of scientific and clinical orthodontics and related areas. All articles undergo peer review before publication. The German Society of Orthodontics (DGKFO) also publishes in the journal important communications, statements and announcements.
期刊最新文献
Correction to: Influence of functional and esthetic expectations on orthodontic pain. Mitteilungen der DGKFO. Dentoskeletal effects of clear aligner vs twin block-a short-term study of functional appliances. Evaluation and comparison of planum clival angle in three malocclusion groups : A CBCT study. Survival rates of mandibular fixed retainers: comparison of a tube-type retainer and conventional multistrand retainers : A prospective randomized clinical trial.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1