肝素涂层和非肝素涂层对称尖端血液透析导管并发症和长期结果的比较。

IF 1.6 3区 医学 Q3 PERIPHERAL VASCULAR DISEASE Journal of Vascular Access Pub Date : 2025-01-01 Epub Date: 2023-10-21 DOI:10.1177/11297298231202536
Mustafa Özdemir, Onur Taydaş, Gürkan Danışan, Ömer Faruk Ateş
{"title":"肝素涂层和非肝素涂层对称尖端血液透析导管并发症和长期结果的比较。","authors":"Mustafa Özdemir, Onur Taydaş, Gürkan Danışan, Ömer Faruk Ateş","doi":"10.1177/11297298231202536","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Tunneled catheters are effectively used in patients receiving chronic dialysis due to end-stage renal disease. However, the dysfunction of catheters caused by infection or thrombus requires repetitive procedures. In this study, we aimed to compare the long-term results of heparin-coated and non-heparin-coated tunneled dialysis catheters.</p><p><strong>Method: </strong>The study included a total of 161 patients who underwent tunneled dialysis catheter placement. Heparin-coated and non-heparin-coated tunneled catheters were placed in 81 and 80 patients, respectively. Of all the patients, 89 (55.3%) were male and 72 (44.7%) were female. The mean age of the patients was 64.3 ± 15.3 years. The patients were followed up for 12 months.</p><p><strong>Results: </strong>Catheter infection developed in 10 (6.2%) of the cases, of which seven (70%) resolved with antibiotic therapy and the remaining three (30%) required catheter replacement. There was no significant difference between the groups in terms of the catheter infection rate (<i>p</i> = 0.84). Fibrin sheaths developed in nine (5.5%) patients. Fibrin sheath development was found to be significantly higher in the non-heparin-coated catheters (<i>p</i> = 0.017). There was no significant difference in fibrin sheath formation between the patients with and without systemic antiaggregant use (<i>p</i> = 0.864). The mean catheter durability time was determined to be 11 months in both groups (<i>p</i> = 0.704). Catheter survival was similar in heparin-coated and non-heparin coated catheters.</p><p><strong>Conclusion: </strong>This study showed that the rate of fibrin sheath development was significantly lower in heparin-coated tunneled catheters than non-heparin-coated catheters. There was no significant difference between the two catheters in terms of the rates of infection and mechanical complications.</p>","PeriodicalId":56113,"journal":{"name":"Journal of Vascular Access","volume":" ","pages":"139-143"},"PeriodicalIF":1.6000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparison of the complications and long-term results of heparin-coated and non-heparin-coated symmetric-tip hemodialysis catheters.\",\"authors\":\"Mustafa Özdemir, Onur Taydaş, Gürkan Danışan, Ömer Faruk Ateş\",\"doi\":\"10.1177/11297298231202536\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Tunneled catheters are effectively used in patients receiving chronic dialysis due to end-stage renal disease. However, the dysfunction of catheters caused by infection or thrombus requires repetitive procedures. In this study, we aimed to compare the long-term results of heparin-coated and non-heparin-coated tunneled dialysis catheters.</p><p><strong>Method: </strong>The study included a total of 161 patients who underwent tunneled dialysis catheter placement. Heparin-coated and non-heparin-coated tunneled catheters were placed in 81 and 80 patients, respectively. Of all the patients, 89 (55.3%) were male and 72 (44.7%) were female. The mean age of the patients was 64.3 ± 15.3 years. The patients were followed up for 12 months.</p><p><strong>Results: </strong>Catheter infection developed in 10 (6.2%) of the cases, of which seven (70%) resolved with antibiotic therapy and the remaining three (30%) required catheter replacement. There was no significant difference between the groups in terms of the catheter infection rate (<i>p</i> = 0.84). Fibrin sheaths developed in nine (5.5%) patients. Fibrin sheath development was found to be significantly higher in the non-heparin-coated catheters (<i>p</i> = 0.017). There was no significant difference in fibrin sheath formation between the patients with and without systemic antiaggregant use (<i>p</i> = 0.864). The mean catheter durability time was determined to be 11 months in both groups (<i>p</i> = 0.704). Catheter survival was similar in heparin-coated and non-heparin coated catheters.</p><p><strong>Conclusion: </strong>This study showed that the rate of fibrin sheath development was significantly lower in heparin-coated tunneled catheters than non-heparin-coated catheters. There was no significant difference between the two catheters in terms of the rates of infection and mechanical complications.</p>\",\"PeriodicalId\":56113,\"journal\":{\"name\":\"Journal of Vascular Access\",\"volume\":\" \",\"pages\":\"139-143\"},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2025-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Vascular Access\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/11297298231202536\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/10/21 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"PERIPHERAL VASCULAR DISEASE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Vascular Access","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/11297298231202536","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/10/21 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
引用次数: 0

摘要

背景:隧道导管可有效用于因终末期肾病而接受慢性透析的患者。然而,感染或血栓引起的导管功能障碍需要重复操作。在本研究中,我们旨在比较肝素涂层和非肝素涂层隧道透析导管的长期结果。方法:本研究共纳入161名接受隧道式透析导管置入术的患者。分别在81名和80名患者中放置肝素涂层和非肝素涂层隧道导管。其中男性89例(55.3%),女性72例(44.7%)。患者的平均年龄为64.3岁 ± 15.3 年。对患者进行了12次随访 月。结果:10例(6.2%)发生导管感染,其中7例(70%)通过抗生素治疗解决,其余3例(30%)需要更换导管。在导管感染率方面,两组之间没有显著差异(p = 0.84)。9名(5.5%)患者出现纤维蛋白鞘。非肝素涂层导管中纤维蛋白鞘的发生率明显较高(p = 0.017)。在使用和不使用系统性抗聚集剂的患者之间,纤维蛋白鞘的形成没有显著差异(p = 0.864)。平均导管耐久时间确定为11 两组的月数(p = 0.704)。肝素涂层和非肝素涂层导管的导管存活率相似。结论:本研究表明,肝素涂层隧道导管的纤维蛋白鞘形成率明显低于非肝素涂层导管。两种导管在感染率和机械并发症方面没有显著差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Comparison of the complications and long-term results of heparin-coated and non-heparin-coated symmetric-tip hemodialysis catheters.

Background: Tunneled catheters are effectively used in patients receiving chronic dialysis due to end-stage renal disease. However, the dysfunction of catheters caused by infection or thrombus requires repetitive procedures. In this study, we aimed to compare the long-term results of heparin-coated and non-heparin-coated tunneled dialysis catheters.

Method: The study included a total of 161 patients who underwent tunneled dialysis catheter placement. Heparin-coated and non-heparin-coated tunneled catheters were placed in 81 and 80 patients, respectively. Of all the patients, 89 (55.3%) were male and 72 (44.7%) were female. The mean age of the patients was 64.3 ± 15.3 years. The patients were followed up for 12 months.

Results: Catheter infection developed in 10 (6.2%) of the cases, of which seven (70%) resolved with antibiotic therapy and the remaining three (30%) required catheter replacement. There was no significant difference between the groups in terms of the catheter infection rate (p = 0.84). Fibrin sheaths developed in nine (5.5%) patients. Fibrin sheath development was found to be significantly higher in the non-heparin-coated catheters (p = 0.017). There was no significant difference in fibrin sheath formation between the patients with and without systemic antiaggregant use (p = 0.864). The mean catheter durability time was determined to be 11 months in both groups (p = 0.704). Catheter survival was similar in heparin-coated and non-heparin coated catheters.

Conclusion: This study showed that the rate of fibrin sheath development was significantly lower in heparin-coated tunneled catheters than non-heparin-coated catheters. There was no significant difference between the two catheters in terms of the rates of infection and mechanical complications.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Vascular Access
Journal of Vascular Access 医学-外周血管病
CiteScore
3.40
自引率
31.60%
发文量
181
审稿时长
6-12 weeks
期刊介绍: The Journal of Vascular Access (JVA) is issued six times per year; it considers the publication of original manuscripts dealing with clinical and laboratory investigations in the fast growing field of vascular access. In addition reviews, case reports and clinical trials are welcome, as well as papers dedicated to more practical aspects covering new devices and techniques. All contributions, coming from all over the world, undergo the peer-review process. The Journal of Vascular Access is divided into independent sections, each led by Editors of the highest scientific level: • Dialysis • Oncology • Interventional radiology • Nutrition • Nursing • Intensive care Correspondence related to published papers is also welcome.
期刊最新文献
Maintenance of peripherally inserted central catheters in general pediatric wards. Staged surgical salvage of an abandoned hemodialysis graft due to small inflow artery variant. Study protocol for paradigm shift in vascular access creation: The VAC study. Utility of the BeBack re-entry catheter to treat resistant cephalic arch occlusion in a haemodialysis patient: Case report and review of the literature. Comparing static versus dynamic ultrasound techniques: A randomized pilot trial of novice and advanced users.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1