使用聚四氟乙烯网片ORIHIME®进行腹腔镜骶骶固定术的中期疗效

Masami Takeyama, Masaki Watanabe, Tomoko Kuwata, Hiromi Kashihara, Chikako Kato
{"title":"使用聚四氟乙烯网片ORIHIME®进行腹腔镜骶骶固定术的中期疗效","authors":"Masami Takeyama,&nbsp;Masaki Watanabe,&nbsp;Tomoko Kuwata,&nbsp;Hiromi Kashihara,&nbsp;Chikako Kato","doi":"10.1016/j.contre.2023.100022","DOIUrl":null,"url":null,"abstract":"<div><p>Since 2017, polytetrafluoroethylene (PTFE) mesh ORIHIME® has been available in Japan for pelvic organ prolapse surgery. PTFE mesh is a potential material for the reconstruction of pelvic floor, however, there have not been any report on the LSC using PTFE mesh. The aim of the study is to confirm the feasibility of LSC with PTFE mesh by investigating the mid-term outcomes of LSC with this mesh. The materials were ORIHIME® and 30 patients with POP who underwent LSC using ORIHIME® in 2018. All cases underwent double mesh LSC, and subtotal hysterectomy was carried out concomitantly. Mean operation time was 145 min. We experienced no intraoperative complication. The patients were to be followed up to 3 years after operation. But only 19 patients were able to be followed up to 3 years. We experienced no mesh related complication. Stress urinary incontinence was seen in 8 patients (27%). As for recurrence of POP, we saw 3 cases (10%). Considering the results, LSC with PTFE mesh may have potential in reconstructing the female pelvic floor of POP patients.</p></div>","PeriodicalId":100330,"journal":{"name":"Continence Reports","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Mid-term performance of laparoscopic sacrocolpopexy using polytetrafluoroethylene mesh ORIHIME®\",\"authors\":\"Masami Takeyama,&nbsp;Masaki Watanabe,&nbsp;Tomoko Kuwata,&nbsp;Hiromi Kashihara,&nbsp;Chikako Kato\",\"doi\":\"10.1016/j.contre.2023.100022\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Since 2017, polytetrafluoroethylene (PTFE) mesh ORIHIME® has been available in Japan for pelvic organ prolapse surgery. PTFE mesh is a potential material for the reconstruction of pelvic floor, however, there have not been any report on the LSC using PTFE mesh. The aim of the study is to confirm the feasibility of LSC with PTFE mesh by investigating the mid-term outcomes of LSC with this mesh. The materials were ORIHIME® and 30 patients with POP who underwent LSC using ORIHIME® in 2018. All cases underwent double mesh LSC, and subtotal hysterectomy was carried out concomitantly. Mean operation time was 145 min. We experienced no intraoperative complication. The patients were to be followed up to 3 years after operation. But only 19 patients were able to be followed up to 3 years. We experienced no mesh related complication. Stress urinary incontinence was seen in 8 patients (27%). As for recurrence of POP, we saw 3 cases (10%). Considering the results, LSC with PTFE mesh may have potential in reconstructing the female pelvic floor of POP patients.</p></div>\",\"PeriodicalId\":100330,\"journal\":{\"name\":\"Continence Reports\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Continence Reports\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2772974523000029\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Continence Reports","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2772974523000029","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

自2017年以来,聚四氟乙烯(PTFE)网状物ORIHIME®已在日本用于盆腔器官脱垂手术。聚四氟乙烯网是重建盆底的一种潜在材料,然而,尚未有任何关于使用聚四氟乙烯网的LSC的报道。本研究的目的是通过调查使用PTFE网片的LSC的中期结果来确认使用PTFE网布的LSC可行性。这些材料是ORIHIME®和30名POP患者,他们在2018年使用ORIHIME™进行了LSC。所有病例均行双层LSC,同时行子宫次全切除术。平均手术时间145分钟。我们没有出现术中并发症。术后随访3年。但只有19名患者能够进行长达3年的随访。我们没有遇到与网状物相关的并发症。压力性尿失禁8例(27%)。POP复发3例(10%)。考虑到这些结果,聚四氟乙烯网的LSC在POP患者的女性盆底重建中可能具有潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Mid-term performance of laparoscopic sacrocolpopexy using polytetrafluoroethylene mesh ORIHIME®

Since 2017, polytetrafluoroethylene (PTFE) mesh ORIHIME® has been available in Japan for pelvic organ prolapse surgery. PTFE mesh is a potential material for the reconstruction of pelvic floor, however, there have not been any report on the LSC using PTFE mesh. The aim of the study is to confirm the feasibility of LSC with PTFE mesh by investigating the mid-term outcomes of LSC with this mesh. The materials were ORIHIME® and 30 patients with POP who underwent LSC using ORIHIME® in 2018. All cases underwent double mesh LSC, and subtotal hysterectomy was carried out concomitantly. Mean operation time was 145 min. We experienced no intraoperative complication. The patients were to be followed up to 3 years after operation. But only 19 patients were able to be followed up to 3 years. We experienced no mesh related complication. Stress urinary incontinence was seen in 8 patients (27%). As for recurrence of POP, we saw 3 cases (10%). Considering the results, LSC with PTFE mesh may have potential in reconstructing the female pelvic floor of POP patients.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Underweight, dementia, and not being completely independent in bowel management are risk factors for urinary incontinence among older people Diagnosis and treatment of nocturnal enuresis throughout the ages The medical management of lower urinary tract symptoms during the nineteenth century The history of prosthetic devices for postprostatectomy incontinence Female urethroplasty using urethral diverticulum tissue as a graft
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1