在2019冠状病毒病大流行期间,建筑物内长时间积水增加了机会性病原体带来的风险

IF 7.2 2区 环境科学与生态学 Q1 ENGINEERING, ENVIRONMENTAL Water Research X Pub Date : 2023-09-09 DOI:10.1016/j.wroa.2023.100201
Casey K Huang , Anjani Weerasekara , Ji Lu , Robyn Carter , Karen D. Weynberg , Rachel Thomson , Scott Bell , Jianhua Guo
{"title":"在2019冠状病毒病大流行期间,建筑物内长时间积水增加了机会性病原体带来的风险","authors":"Casey K Huang ,&nbsp;Anjani Weerasekara ,&nbsp;Ji Lu ,&nbsp;Robyn Carter ,&nbsp;Karen D. Weynberg ,&nbsp;Rachel Thomson ,&nbsp;Scott Bell ,&nbsp;Jianhua Guo","doi":"10.1016/j.wroa.2023.100201","DOIUrl":null,"url":null,"abstract":"<div><p>The regrowth and subsequent exposure of opportunistic pathogens (OPs) whilst reopening buildings that have been locked down due to the stay-at-home restrictions to limit the spread of COVID-19, is a public health concern. To better understand such microbiological risks due to lowered occupancy and water demand in buildings, first and post-flush water samples (n = 48) were sampled from 24 drinking water outlets from eight university buildings in two campuses (urban and rural), with various end-user occupancies. Both campuses were served with chlorinated water originating from a single drinking water distribution system in South-East Queensland, situated 14 km apart, where the rural campus had lower chlorine residuals. Culture-dependent and culture-independent methods (such as flow cytometry, qPCR and 16S rRNA gene amplicon sequencing) were used concurrently to comprehensively characterise the OPs of interest (<em>Legionella</em> spp., <em>Pseudomonas aeruginosa</em>, and nontuberculous mycobacteria (NTM)) and the premise plumbing microbiome. Results showed that buildings with extended levels of stagnation had higher and diverse levels of microbial growth, as observed in taxonomic structure and composition of the microbial communities. NTM were ubiquitous in all the outlets sampled, regardless of campus or end-user occupancy of the buildings. qPCR and culture demonstrated prevalent and higher concentrations of NTM in buildings (averaging 3.25 log<sub>10</sub>[estimated genomic copies/mL]) with extended stagnation in the urban campus. Furthermore, flushing the outlets for 30 minutes restored residual and total chlorine, and subsequently decreased the levels of <em>Legionella</em> by a reduction of 1 log. However, this approach was insufficient to restore total and residual chlorine levels for the outlets in the rural campus, where both <em>Legionella</em> and NTM levels detected by qPCR remained unchanged, regardless of building occupancy. Our findings highlight that regular monitoring of operational parameters such as residual chlorine levels, and the implementation of water risk management plans are important for non-healthcare public buildings, as the levels of OPs in these environments are typically not assessed.</p></div>","PeriodicalId":52198,"journal":{"name":"Water Research X","volume":null,"pages":null},"PeriodicalIF":7.2000,"publicationDate":"2023-09-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Extended water stagnation in buildings during the COVID-19 pandemic increases the risks posed by opportunistic pathogens\",\"authors\":\"Casey K Huang ,&nbsp;Anjani Weerasekara ,&nbsp;Ji Lu ,&nbsp;Robyn Carter ,&nbsp;Karen D. Weynberg ,&nbsp;Rachel Thomson ,&nbsp;Scott Bell ,&nbsp;Jianhua Guo\",\"doi\":\"10.1016/j.wroa.2023.100201\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>The regrowth and subsequent exposure of opportunistic pathogens (OPs) whilst reopening buildings that have been locked down due to the stay-at-home restrictions to limit the spread of COVID-19, is a public health concern. To better understand such microbiological risks due to lowered occupancy and water demand in buildings, first and post-flush water samples (n = 48) were sampled from 24 drinking water outlets from eight university buildings in two campuses (urban and rural), with various end-user occupancies. Both campuses were served with chlorinated water originating from a single drinking water distribution system in South-East Queensland, situated 14 km apart, where the rural campus had lower chlorine residuals. Culture-dependent and culture-independent methods (such as flow cytometry, qPCR and 16S rRNA gene amplicon sequencing) were used concurrently to comprehensively characterise the OPs of interest (<em>Legionella</em> spp., <em>Pseudomonas aeruginosa</em>, and nontuberculous mycobacteria (NTM)) and the premise plumbing microbiome. Results showed that buildings with extended levels of stagnation had higher and diverse levels of microbial growth, as observed in taxonomic structure and composition of the microbial communities. NTM were ubiquitous in all the outlets sampled, regardless of campus or end-user occupancy of the buildings. qPCR and culture demonstrated prevalent and higher concentrations of NTM in buildings (averaging 3.25 log<sub>10</sub>[estimated genomic copies/mL]) with extended stagnation in the urban campus. Furthermore, flushing the outlets for 30 minutes restored residual and total chlorine, and subsequently decreased the levels of <em>Legionella</em> by a reduction of 1 log. However, this approach was insufficient to restore total and residual chlorine levels for the outlets in the rural campus, where both <em>Legionella</em> and NTM levels detected by qPCR remained unchanged, regardless of building occupancy. Our findings highlight that regular monitoring of operational parameters such as residual chlorine levels, and the implementation of water risk management plans are important for non-healthcare public buildings, as the levels of OPs in these environments are typically not assessed.</p></div>\",\"PeriodicalId\":52198,\"journal\":{\"name\":\"Water Research X\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":7.2000,\"publicationDate\":\"2023-09-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Water Research X\",\"FirstCategoryId\":\"93\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2589914723000373\",\"RegionNum\":2,\"RegionCategory\":\"环境科学与生态学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, ENVIRONMENTAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Water Research X","FirstCategoryId":"93","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2589914723000373","RegionNum":2,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ENVIRONMENTAL","Score":null,"Total":0}
引用次数: 0

摘要

在重新开放因限制新冠肺炎传播的居家限制而被封锁的建筑时,机会病原体(OP)的再生和随后的暴露是一个公共卫生问题。为了更好地了解由于建筑物的占用率和用水需求降低而产生的微生物风险,从两个校区(城市和农村)的八所大学建筑的24个饮用水出口抽取了首次和后冲洗水样本(n=48),最终用户占用率各不相同。两个校区都使用来自昆士兰东南部一个饮用水分配系统的氯化水,该系统相距14公里,农村校区的氯残留量较低。同时使用培养依赖性和培养非依赖性方法(如流式细胞术、qPCR和16S rRNA基因扩增子测序)来全面表征感兴趣的OP(军团菌属、铜绿假单胞菌和非结核分枝杆菌(NTM))和前提管道微生物组。结果表明,从微生物群落的分类结构和组成来看,长期停滞的建筑具有更高和多样化的微生物生长水平。NTM在所有采样的门店中无处不在,无论校园或建筑物的最终用户占用情况如何。qPCR和培养表明,NTM在建筑物中普遍存在且浓度较高(平均3.25 log10[估计基因组拷贝数/mL]),在城市校园中长期停滞。此外,冲洗出口30分钟可恢复残留氯和总氯,随后将军团菌水平降低1 log。然而,这种方法不足以恢复农村校园出口的总氯和余氯水平,无论建筑物占用情况如何,qPCR检测到的军团菌和NTM水平都保持不变。我们的研究结果强调,定期监测运行参数(如余氯水平)和实施水风险管理计划对非医疗保健公共建筑很重要,因为这些环境中的OP水平通常不会得到评估。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Extended water stagnation in buildings during the COVID-19 pandemic increases the risks posed by opportunistic pathogens

The regrowth and subsequent exposure of opportunistic pathogens (OPs) whilst reopening buildings that have been locked down due to the stay-at-home restrictions to limit the spread of COVID-19, is a public health concern. To better understand such microbiological risks due to lowered occupancy and water demand in buildings, first and post-flush water samples (n = 48) were sampled from 24 drinking water outlets from eight university buildings in two campuses (urban and rural), with various end-user occupancies. Both campuses were served with chlorinated water originating from a single drinking water distribution system in South-East Queensland, situated 14 km apart, where the rural campus had lower chlorine residuals. Culture-dependent and culture-independent methods (such as flow cytometry, qPCR and 16S rRNA gene amplicon sequencing) were used concurrently to comprehensively characterise the OPs of interest (Legionella spp., Pseudomonas aeruginosa, and nontuberculous mycobacteria (NTM)) and the premise plumbing microbiome. Results showed that buildings with extended levels of stagnation had higher and diverse levels of microbial growth, as observed in taxonomic structure and composition of the microbial communities. NTM were ubiquitous in all the outlets sampled, regardless of campus or end-user occupancy of the buildings. qPCR and culture demonstrated prevalent and higher concentrations of NTM in buildings (averaging 3.25 log10[estimated genomic copies/mL]) with extended stagnation in the urban campus. Furthermore, flushing the outlets for 30 minutes restored residual and total chlorine, and subsequently decreased the levels of Legionella by a reduction of 1 log. However, this approach was insufficient to restore total and residual chlorine levels for the outlets in the rural campus, where both Legionella and NTM levels detected by qPCR remained unchanged, regardless of building occupancy. Our findings highlight that regular monitoring of operational parameters such as residual chlorine levels, and the implementation of water risk management plans are important for non-healthcare public buildings, as the levels of OPs in these environments are typically not assessed.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Water Research X
Water Research X Environmental Science-Water Science and Technology
CiteScore
12.30
自引率
1.30%
发文量
19
期刊介绍: Water Research X is a sister journal of Water Research, which follows a Gold Open Access model. It focuses on publishing concise, letter-style research papers, visionary perspectives and editorials, as well as mini-reviews on emerging topics. The Journal invites contributions from researchers worldwide on various aspects of the science and technology related to the human impact on the water cycle, water quality, and its global management.
期刊最新文献
Characterization of EPS subfractions from a mixed culture predominated by partial-denitrification functional bacteria Effectiveness of cyclic treatment of municipal wastewater by Tetradesmus obliquus – Loofah biofilm, its internal community changes and potential for resource utilization Enhanced nitrogen removal for low C/N wastewater via preventing futile carbon oxidation and augmenting anammox Evaluating energy balance and environmental footprint of sludge management in BRICS countries Pharmaceuticals in raw and treated water from drinking water treatment plants nationwide: Insights into their sources and exposure risk assessment
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1