比例积分降解控制允许精确跟踪生物分子浓度与较少的化学反应

Mathias Foo;Jongrae Kim;Jongmin Kim;Declan G. Bates
{"title":"比例积分降解控制允许精确跟踪生物分子浓度与较少的化学反应","authors":"Mathias Foo;Jongrae Kim;Jongmin Kim;Declan G. Bates","doi":"10.1109/LLS.2016.2644652","DOIUrl":null,"url":null,"abstract":"We consider the design of synthetic embedded feedback circuits that can implement desired changes in the concentration of the output of a biomolecular process (\n<italic>reference tracking</i>\n in control terminology). Such systems require the use of a “subtractor” to generate an error signal that captures the difference between the current and desired values of the process output. Unfortunately, standard implementations of the subtraction operator using chemical reaction networks are one sided, i.e., they cannot produce negative error signals. Previous attempts to deal with this problem by representing signals as the difference in concentrations of two different biomolecular species lead to a doubling of the number of chemical reactions required to generate the circuit, hence sharply increasing the difficulty of experimental implementations and limiting the complexity of potential designs. Here, we propose an alternative approach that introduces a degradation term into the classical proportion–integral (PI) control scheme. The extra tuning flexibility of the PI degradation controller compensates for the limitations of the one-sided subtraction operator, providing robust high-performance tracking of concentration changes with a minimal number of chemical reactions.","PeriodicalId":87271,"journal":{"name":"IEEE life sciences letters","volume":"2 4","pages":"55-58"},"PeriodicalIF":0.0000,"publicationDate":"2016-12-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1109/LLS.2016.2644652","citationCount":"4","resultStr":"{\"title\":\"Proportional–Integral Degradation Control Allows Accurate Tracking of Biomolecular Concentrations With Fewer Chemical Reactions\",\"authors\":\"Mathias Foo;Jongrae Kim;Jongmin Kim;Declan G. Bates\",\"doi\":\"10.1109/LLS.2016.2644652\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We consider the design of synthetic embedded feedback circuits that can implement desired changes in the concentration of the output of a biomolecular process (\\n<italic>reference tracking</i>\\n in control terminology). Such systems require the use of a “subtractor” to generate an error signal that captures the difference between the current and desired values of the process output. Unfortunately, standard implementations of the subtraction operator using chemical reaction networks are one sided, i.e., they cannot produce negative error signals. Previous attempts to deal with this problem by representing signals as the difference in concentrations of two different biomolecular species lead to a doubling of the number of chemical reactions required to generate the circuit, hence sharply increasing the difficulty of experimental implementations and limiting the complexity of potential designs. Here, we propose an alternative approach that introduces a degradation term into the classical proportion–integral (PI) control scheme. The extra tuning flexibility of the PI degradation controller compensates for the limitations of the one-sided subtraction operator, providing robust high-performance tracking of concentration changes with a minimal number of chemical reactions.\",\"PeriodicalId\":87271,\"journal\":{\"name\":\"IEEE life sciences letters\",\"volume\":\"2 4\",\"pages\":\"55-58\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-12-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1109/LLS.2016.2644652\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE life sciences letters\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/7797243/\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE life sciences letters","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/7797243/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

我们考虑设计合成嵌入式反馈电路,可以实现生物分子过程输出浓度的期望变化(控制术语中的参考跟踪)。这种系统需要使用“减法器”来产生一个错误信号,该信号捕获过程输出的电流值和期望值之间的差值。不幸的是,使用化学反应网络的减法算子的标准实现是片面的,即它们不能产生负误差信号。先前的尝试是将信号表示为两种不同生物分子的浓度差异,导致生成电路所需的化学反应数量增加一倍,从而大大增加了实验实现的难度,并限制了潜在设计的复杂性。在这里,我们提出了一种替代方法,在经典的比例积分(PI)控制方案中引入退化项。PI退化控制器的额外调整灵活性补偿了单侧减法算子的局限性,以最少的化学反应数量提供了强大的高性能浓度变化跟踪。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Proportional–Integral Degradation Control Allows Accurate Tracking of Biomolecular Concentrations With Fewer Chemical Reactions
We consider the design of synthetic embedded feedback circuits that can implement desired changes in the concentration of the output of a biomolecular process ( reference tracking in control terminology). Such systems require the use of a “subtractor” to generate an error signal that captures the difference between the current and desired values of the process output. Unfortunately, standard implementations of the subtraction operator using chemical reaction networks are one sided, i.e., they cannot produce negative error signals. Previous attempts to deal with this problem by representing signals as the difference in concentrations of two different biomolecular species lead to a doubling of the number of chemical reactions required to generate the circuit, hence sharply increasing the difficulty of experimental implementations and limiting the complexity of potential designs. Here, we propose an alternative approach that introduces a degradation term into the classical proportion–integral (PI) control scheme. The extra tuning flexibility of the PI degradation controller compensates for the limitations of the one-sided subtraction operator, providing robust high-performance tracking of concentration changes with a minimal number of chemical reactions.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Narrative impairment, white matter damage and CSF biomarkers in the Alzheimer's disease spectrum. Table of contents The Age-Related Effect of Nicotine on the Expression of Neuroprotective Genes in Ventral Tegmental Area and Substantia Nigra A Delay-Based Sustained Chemical Oscillator: Qualitative Analysis of Oregonator-Based Models Table of contents
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1