金属-聚合物和双金属-聚合物无铅辐射屏蔽的效率如何?

IF 1.8 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Journal of Medical Radiation Sciences Pub Date : 2023-10-24 DOI:10.1002/jmrs.733
Zaker Salehi PhD, Mansour Tayebi Khorami PhD
{"title":"金属-聚合物和双金属-聚合物无铅辐射屏蔽的效率如何?","authors":"Zaker Salehi PhD,&nbsp;Mansour Tayebi Khorami PhD","doi":"10.1002/jmrs.733","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Introduction</h3>\n \n <p>Lead shields are often used to attenuate ionising radiations. However, to make lighter, recyclable and more efficient shields compared to lead, combinations of new metallic compounds together with polymer, for example, flexible polyvinyl chloride (PVC) have been developed recently. In this study, the capabilities of non-lead radiation shields made of one or two metallic compounds and polymer were evaluated.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>Monte Carlo (MC)-based BEAMnrc code was used to build a functional model based on a Philips X-ray machine in the range of radiographic energies. The MC model was then verified by IPEM Report 78 as a standardised global reference. The MC model was then used to evaluate the efficiency of non-lead-based garments made of metallic compound and polymer (MCP) including BaSO<sub>4</sub>-PVC, Bi<sub>2</sub>O<sub>3</sub>-PVC, Sn-PVC and W-PVC, as well as dual-metallic compounds and polymer (DMCP) including Bi<sub>2</sub>O<sub>3</sub>-BaSO<sub>4</sub>-PVC, Bi<sub>2</sub>O<sub>3</sub>-Sn-PVC, W-Sn-PVC and W-BaSO<sub>4</sub>-PVC. The absorbed doses were determined at the surface of a water phantom and compared directly with the doses obtained for 0.5 mm pure lead (Pb).</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>Bi<sub>2</sub>O<sub>3</sub>-BaSO<sub>4</sub>-PVC and W-BaSO<sub>4</sub>-PVC were found to be efficient shields for most of the energies. In addition to the above radiation shields, Bi<sub>2</sub>O<sub>3</sub>-Sn-PVC was also found to be effective for the spectrum of 60 keV. Bi<sub>2</sub>O<sub>3</sub>-BaSO<sub>4</sub>-PVC as a non-lead dual metals-PVC shield was shown to be more efficient than pure lead in diagnostic X-ray range.</p>\n </section>\n \n <section>\n \n <h3> Conclusion</h3>\n \n <p>Combination of two metals-PVC, a low atomic number (Z) metal together with a high atomic number metal, and also single-metal-PVC shields were shown to be efficient enough to apply as radiation protection shields instead of lead-based garments.</p>\n </section>\n </div>","PeriodicalId":16382,"journal":{"name":"Journal of Medical Radiation Sciences","volume":"71 1","pages":"57-62"},"PeriodicalIF":1.8000,"publicationDate":"2023-10-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/jmrs.733","citationCount":"0","resultStr":"{\"title\":\"How efficient are metal-polymer and dual-metals-polymer non-lead radiation shields?\",\"authors\":\"Zaker Salehi PhD,&nbsp;Mansour Tayebi Khorami PhD\",\"doi\":\"10.1002/jmrs.733\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n \\n <section>\\n \\n <h3> Introduction</h3>\\n \\n <p>Lead shields are often used to attenuate ionising radiations. However, to make lighter, recyclable and more efficient shields compared to lead, combinations of new metallic compounds together with polymer, for example, flexible polyvinyl chloride (PVC) have been developed recently. In this study, the capabilities of non-lead radiation shields made of one or two metallic compounds and polymer were evaluated.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Methods</h3>\\n \\n <p>Monte Carlo (MC)-based BEAMnrc code was used to build a functional model based on a Philips X-ray machine in the range of radiographic energies. The MC model was then verified by IPEM Report 78 as a standardised global reference. The MC model was then used to evaluate the efficiency of non-lead-based garments made of metallic compound and polymer (MCP) including BaSO<sub>4</sub>-PVC, Bi<sub>2</sub>O<sub>3</sub>-PVC, Sn-PVC and W-PVC, as well as dual-metallic compounds and polymer (DMCP) including Bi<sub>2</sub>O<sub>3</sub>-BaSO<sub>4</sub>-PVC, Bi<sub>2</sub>O<sub>3</sub>-Sn-PVC, W-Sn-PVC and W-BaSO<sub>4</sub>-PVC. The absorbed doses were determined at the surface of a water phantom and compared directly with the doses obtained for 0.5 mm pure lead (Pb).</p>\\n </section>\\n \\n <section>\\n \\n <h3> Results</h3>\\n \\n <p>Bi<sub>2</sub>O<sub>3</sub>-BaSO<sub>4</sub>-PVC and W-BaSO<sub>4</sub>-PVC were found to be efficient shields for most of the energies. In addition to the above radiation shields, Bi<sub>2</sub>O<sub>3</sub>-Sn-PVC was also found to be effective for the spectrum of 60 keV. Bi<sub>2</sub>O<sub>3</sub>-BaSO<sub>4</sub>-PVC as a non-lead dual metals-PVC shield was shown to be more efficient than pure lead in diagnostic X-ray range.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Conclusion</h3>\\n \\n <p>Combination of two metals-PVC, a low atomic number (Z) metal together with a high atomic number metal, and also single-metal-PVC shields were shown to be efficient enough to apply as radiation protection shields instead of lead-based garments.</p>\\n </section>\\n </div>\",\"PeriodicalId\":16382,\"journal\":{\"name\":\"Journal of Medical Radiation Sciences\",\"volume\":\"71 1\",\"pages\":\"57-62\"},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2023-10-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1002/jmrs.733\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Medical Radiation Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/jmrs.733\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medical Radiation Sciences","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/jmrs.733","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

简介:铅屏蔽通常用于衰减电离辐射。然而,为了制造比铅更轻、可回收和更高效的屏蔽,最近开发了新的金属化合物与聚合物的组合,例如柔性聚氯乙烯(PVC)。在这项研究中,评估了由一种或两种金属化合物和聚合物制成的非铅辐射屏蔽的性能。方法:使用基于蒙特卡罗(MC)的BEAMnrc程序,在Philips X光机上建立射线能量范围内的函数模型。然后,IPEM报告78验证了MC模型作为标准化全球参考。然后使用MC模型来评估由金属化合物和聚合物(MCP)(包括BaSO4-PVC、Bi2 O3-PVC、Sn-PVC和W-PVC)以及双金属化合物和共聚物(DMCP)(包括Bi2 O3-BaSO4-PVC、Bi2 O3-Sn-聚氯乙烯、W-Sn-PVC和W-BaSO4-聚氯乙烯)制成的非铅基服装的效率。在水模型的表面测定吸收的剂量,并将其与0.5 mm纯铅(Pb)。结果:Bi2O3-BaSO4-PVC和W-BaSO4-聚氯乙烯对大部分能量具有有效的屏蔽作用。除上述辐射屏蔽外,还发现Bi2O3-Sn-PVC对60 keV。Bi2O3-BaSO4-PVC作为一种非铅双金属PVC屏蔽材料,在诊断X射线范围内比纯铅更有效。结论:两种金属PVC,一种低原子序数(Z)金属与一种高原子序数金属的组合,以及单一金属PVC防护罩被证明足够有效,可以代替铅基服装用作辐射防护罩。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
How efficient are metal-polymer and dual-metals-polymer non-lead radiation shields?

Introduction

Lead shields are often used to attenuate ionising radiations. However, to make lighter, recyclable and more efficient shields compared to lead, combinations of new metallic compounds together with polymer, for example, flexible polyvinyl chloride (PVC) have been developed recently. In this study, the capabilities of non-lead radiation shields made of one or two metallic compounds and polymer were evaluated.

Methods

Monte Carlo (MC)-based BEAMnrc code was used to build a functional model based on a Philips X-ray machine in the range of radiographic energies. The MC model was then verified by IPEM Report 78 as a standardised global reference. The MC model was then used to evaluate the efficiency of non-lead-based garments made of metallic compound and polymer (MCP) including BaSO4-PVC, Bi2O3-PVC, Sn-PVC and W-PVC, as well as dual-metallic compounds and polymer (DMCP) including Bi2O3-BaSO4-PVC, Bi2O3-Sn-PVC, W-Sn-PVC and W-BaSO4-PVC. The absorbed doses were determined at the surface of a water phantom and compared directly with the doses obtained for 0.5 mm pure lead (Pb).

Results

Bi2O3-BaSO4-PVC and W-BaSO4-PVC were found to be efficient shields for most of the energies. In addition to the above radiation shields, Bi2O3-Sn-PVC was also found to be effective for the spectrum of 60 keV. Bi2O3-BaSO4-PVC as a non-lead dual metals-PVC shield was shown to be more efficient than pure lead in diagnostic X-ray range.

Conclusion

Combination of two metals-PVC, a low atomic number (Z) metal together with a high atomic number metal, and also single-metal-PVC shields were shown to be efficient enough to apply as radiation protection shields instead of lead-based garments.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Medical Radiation Sciences
Journal of Medical Radiation Sciences RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
3.20
自引率
4.80%
发文量
69
审稿时长
8 weeks
期刊介绍: Journal of Medical Radiation Sciences (JMRS) is an international and multidisciplinary peer-reviewed journal that accepts manuscripts related to medical imaging / diagnostic radiography, radiation therapy, nuclear medicine, medical ultrasound / sonography, and the complementary disciplines of medical physics, radiology, radiation oncology, nursing, psychology and sociology. Manuscripts may take the form of: original articles, review articles, commentary articles, technical evaluations, case series and case studies. JMRS promotes excellence in international medical radiation science by the publication of contemporary and advanced research that encourages the adoption of the best clinical, scientific and educational practices in international communities. JMRS is the official professional journal of the Australian Society of Medical Imaging and Radiation Therapy (ASMIRT) and the New Zealand Institute of Medical Radiation Technology (NZIMRT).
期刊最新文献
Sonographic localisation of lymph nodes suspicious of metastatic breast cancer to surgical axillary levels. Impact of pre-examination video education in Gd-EOB-DTPA-enhanced liver MRI: A comparative study. Enhancing medical imaging education: integrating computing technologies, digital image processing and artificial intelligence. Deep learning in image segmentation for cancer. Molecular theranostics: principles, challenges and controversies.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1