{"title":"一种用荧光报告蛋白定量厌氧和微需氧基因表达的简单方法。","authors":"Lucas Pedraz, Eduard Torrents","doi":"10.2144/btn-2023-0064","DOIUrl":null,"url":null,"abstract":"<p><p>Fluorescent proteins, such as green fluorescent proteins, are invaluable tools for detecting and quantifying gene expression in high-throughput reporter gene assays. However, they introduce significant inaccuracies in studies involving microaerobiosis or anaerobiosis, as oxygen is required for the maturation of these proteins' chromophores. In this study, the authors highlight the errors incurred by using fluorescent proteins under limited oxygenation by comparing standard fluorescence-based reporter gene assays to quantitative real-time PCR data in the study of a complex oxygen-regulated gene network. Furthermore, a solution to perform quantification of anaerobic and microaerobic gene expression with fluorescent reporter proteins using a microplate reader with an oxygen control system and applying pulses of full oxygenation before fluorescence measurements is provided.</p>","PeriodicalId":8945,"journal":{"name":"BioTechniques","volume":" ","pages":"250-255"},"PeriodicalIF":2.2000,"publicationDate":"2023-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"An easy method for quantification of anaerobic and microaerobic gene expression with fluorescent reporter proteins.\",\"authors\":\"Lucas Pedraz, Eduard Torrents\",\"doi\":\"10.2144/btn-2023-0064\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Fluorescent proteins, such as green fluorescent proteins, are invaluable tools for detecting and quantifying gene expression in high-throughput reporter gene assays. However, they introduce significant inaccuracies in studies involving microaerobiosis or anaerobiosis, as oxygen is required for the maturation of these proteins' chromophores. In this study, the authors highlight the errors incurred by using fluorescent proteins under limited oxygenation by comparing standard fluorescence-based reporter gene assays to quantitative real-time PCR data in the study of a complex oxygen-regulated gene network. Furthermore, a solution to perform quantification of anaerobic and microaerobic gene expression with fluorescent reporter proteins using a microplate reader with an oxygen control system and applying pulses of full oxygenation before fluorescence measurements is provided.</p>\",\"PeriodicalId\":8945,\"journal\":{\"name\":\"BioTechniques\",\"volume\":\" \",\"pages\":\"250-255\"},\"PeriodicalIF\":2.2000,\"publicationDate\":\"2023-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"BioTechniques\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.2144/btn-2023-0064\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/10/26 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"BioTechniques","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.2144/btn-2023-0064","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/10/26 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
An easy method for quantification of anaerobic and microaerobic gene expression with fluorescent reporter proteins.
Fluorescent proteins, such as green fluorescent proteins, are invaluable tools for detecting and quantifying gene expression in high-throughput reporter gene assays. However, they introduce significant inaccuracies in studies involving microaerobiosis or anaerobiosis, as oxygen is required for the maturation of these proteins' chromophores. In this study, the authors highlight the errors incurred by using fluorescent proteins under limited oxygenation by comparing standard fluorescence-based reporter gene assays to quantitative real-time PCR data in the study of a complex oxygen-regulated gene network. Furthermore, a solution to perform quantification of anaerobic and microaerobic gene expression with fluorescent reporter proteins using a microplate reader with an oxygen control system and applying pulses of full oxygenation before fluorescence measurements is provided.
期刊介绍:
BioTechniques is a peer-reviewed, open-access journal dedicated to publishing original laboratory methods, related technical and software tools, and methods-oriented review articles that are of broad interest to professional life scientists, as well as to scientists from other disciplines (e.g., chemistry, physics, computer science, plant and agricultural science and climate science) interested in life science applications for their technologies.
Since 1983, BioTechniques has been a leading peer-reviewed journal for methods-related research. The journal considers:
Reports describing innovative new methods, platforms and software, substantive modifications to existing methods, or innovative applications of existing methods, techniques & tools to new models or scientific questions
Descriptions of technical tools that facilitate the design or performance of experiments or data analysis, such as software and simple laboratory devices
Surveys of technical approaches related to broad fields of research
Reviews discussing advancements in techniques and methods related to broad fields of research
Letters to the Editor and Expert Opinions highlighting interesting observations or cautionary tales concerning experimental design, methodology or analysis.