Hao Wang , Hong-Bing Shi , Wei-Guang Qiang, Chao Wang, Bai Sun, Ye Yuan, Wen-Wei Hu
{"title":"CT引导放射性125I粒子植入治疗癌症腹部切口转移17例安全性和有效性","authors":"Hao Wang , Hong-Bing Shi , Wei-Guang Qiang, Chao Wang, Bai Sun, Ye Yuan, Wen-Wei Hu","doi":"10.1016/j.clcc.2022.10.004","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction</h3><p><span>To retrospectively evaluate the safety and efficacy of computed tomography (CT)-guided iodine-125 (</span><sup>125</sup><span>I) seed implantation for patients with abdominal incision<span> metastases from colorectal cancer.</span></span></p></div><div><h3>Materials and Methods</h3><p>Data of patients with abdominal incision metastases of colorectal cancer from November 2010 to October 2020 were retrospectively reviewed. Each incisional metastasis was percutaneously treated with <sup>125</sup>I seed implantation under CT guidance. Follow-up contrast-enhanced CT was reviewed, and the outcomes were evaluated in terms of objective response rate, complications, and overall survival.</p></div><div><h3>Results</h3><p>A total of 17 patients were enrolled in this study. The median follow-up was 18 months (range, 2.7-22.1 months). At 3, 6, 12, and 18 months after the treatment, objective response rate was 52.9%, 63.6%, 33.3%, and 0%, respectively. A small amount of local hematoma occurred in two patients and resolved spontaneously without any treatment. Two patients experienced a minor displacement of radioactive seeds with no related symptoms. Severe complications, such as massive bleeding and radiation injury, were not observed. No ≥ grade 3 adverse events were identified. By the end of follow-up, 14 patients died of multiple hematogenous metastases. The one-year overall survival rate was 41.6%, and the median overall survival was 8.6 months.</p></div><div><h3>Conclusion</h3><p>CT-guided <sup>125</sup><span>I seed implantation brachytherapy is safe and feasible for patients with abdominal incision metastases from colorectal cancer.</span></p></div>","PeriodicalId":3,"journal":{"name":"ACS Applied Electronic Materials","volume":null,"pages":null},"PeriodicalIF":4.3000,"publicationDate":"2023-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"CT-guided Radioactive 125I Seed Implantation for Abdominal Incision Metastases of Colorectal Cancer: Safety and Efficacy in 17 Patients\",\"authors\":\"Hao Wang , Hong-Bing Shi , Wei-Guang Qiang, Chao Wang, Bai Sun, Ye Yuan, Wen-Wei Hu\",\"doi\":\"10.1016/j.clcc.2022.10.004\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Introduction</h3><p><span>To retrospectively evaluate the safety and efficacy of computed tomography (CT)-guided iodine-125 (</span><sup>125</sup><span>I) seed implantation for patients with abdominal incision<span> metastases from colorectal cancer.</span></span></p></div><div><h3>Materials and Methods</h3><p>Data of patients with abdominal incision metastases of colorectal cancer from November 2010 to October 2020 were retrospectively reviewed. Each incisional metastasis was percutaneously treated with <sup>125</sup>I seed implantation under CT guidance. Follow-up contrast-enhanced CT was reviewed, and the outcomes were evaluated in terms of objective response rate, complications, and overall survival.</p></div><div><h3>Results</h3><p>A total of 17 patients were enrolled in this study. The median follow-up was 18 months (range, 2.7-22.1 months). At 3, 6, 12, and 18 months after the treatment, objective response rate was 52.9%, 63.6%, 33.3%, and 0%, respectively. A small amount of local hematoma occurred in two patients and resolved spontaneously without any treatment. Two patients experienced a minor displacement of radioactive seeds with no related symptoms. Severe complications, such as massive bleeding and radiation injury, were not observed. No ≥ grade 3 adverse events were identified. By the end of follow-up, 14 patients died of multiple hematogenous metastases. The one-year overall survival rate was 41.6%, and the median overall survival was 8.6 months.</p></div><div><h3>Conclusion</h3><p>CT-guided <sup>125</sup><span>I seed implantation brachytherapy is safe and feasible for patients with abdominal incision metastases from colorectal cancer.</span></p></div>\",\"PeriodicalId\":3,\"journal\":{\"name\":\"ACS Applied Electronic Materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.3000,\"publicationDate\":\"2023-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Electronic Materials\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1533002822001086\",\"RegionNum\":3,\"RegionCategory\":\"材料科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Electronic Materials","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1533002822001086","RegionNum":3,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
CT-guided Radioactive 125I Seed Implantation for Abdominal Incision Metastases of Colorectal Cancer: Safety and Efficacy in 17 Patients
Introduction
To retrospectively evaluate the safety and efficacy of computed tomography (CT)-guided iodine-125 (125I) seed implantation for patients with abdominal incision metastases from colorectal cancer.
Materials and Methods
Data of patients with abdominal incision metastases of colorectal cancer from November 2010 to October 2020 were retrospectively reviewed. Each incisional metastasis was percutaneously treated with 125I seed implantation under CT guidance. Follow-up contrast-enhanced CT was reviewed, and the outcomes were evaluated in terms of objective response rate, complications, and overall survival.
Results
A total of 17 patients were enrolled in this study. The median follow-up was 18 months (range, 2.7-22.1 months). At 3, 6, 12, and 18 months after the treatment, objective response rate was 52.9%, 63.6%, 33.3%, and 0%, respectively. A small amount of local hematoma occurred in two patients and resolved spontaneously without any treatment. Two patients experienced a minor displacement of radioactive seeds with no related symptoms. Severe complications, such as massive bleeding and radiation injury, were not observed. No ≥ grade 3 adverse events were identified. By the end of follow-up, 14 patients died of multiple hematogenous metastases. The one-year overall survival rate was 41.6%, and the median overall survival was 8.6 months.
Conclusion
CT-guided 125I seed implantation brachytherapy is safe and feasible for patients with abdominal incision metastases from colorectal cancer.