用于内部PM机器驱动的故障中断方法和拓扑结构

B.A. Welchko;T.M. Jahns;T.A. Lipo
{"title":"用于内部PM机器驱动的故障中断方法和拓扑结构","authors":"B.A. Welchko;T.M. Jahns;T.A. Lipo","doi":"10.1109/LPEL.2004.841494","DOIUrl":null,"url":null,"abstract":"This work investigates methods to interrupt the phase currents induced when interior permanent magnet (IPM) machine drives suffer short-circuit or uncontrolled generator mode faults. A fault-tolerant silicon switch is proposed in which the antiparallel diode in a reverse-blocking inverter switch is replaced by a thyristor. A reduced-parts-count fault-interrupting topology is also proposed which consists of delta-connected thyristors inserted at the center star point of wye-connected IPM machine stator windings. Control of the proposed reduced-parts-count fault-tolerant drive is discussed and simulation results are presented to verify operation of the proposed topology.","PeriodicalId":100635,"journal":{"name":"IEEE Power Electronics Letters","volume":"2 4","pages":"139-143"},"PeriodicalIF":0.0000,"publicationDate":"2004-12-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1109/LPEL.2004.841494","citationCount":"19","resultStr":"{\"title\":\"Fault interrupting methods and topologies for interior PM machine drives\",\"authors\":\"B.A. Welchko;T.M. Jahns;T.A. Lipo\",\"doi\":\"10.1109/LPEL.2004.841494\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This work investigates methods to interrupt the phase currents induced when interior permanent magnet (IPM) machine drives suffer short-circuit or uncontrolled generator mode faults. A fault-tolerant silicon switch is proposed in which the antiparallel diode in a reverse-blocking inverter switch is replaced by a thyristor. A reduced-parts-count fault-interrupting topology is also proposed which consists of delta-connected thyristors inserted at the center star point of wye-connected IPM machine stator windings. Control of the proposed reduced-parts-count fault-tolerant drive is discussed and simulation results are presented to verify operation of the proposed topology.\",\"PeriodicalId\":100635,\"journal\":{\"name\":\"IEEE Power Electronics Letters\",\"volume\":\"2 4\",\"pages\":\"139-143\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2004-12-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1109/LPEL.2004.841494\",\"citationCount\":\"19\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Power Electronics Letters\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/1372511/\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Power Electronics Letters","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/1372511/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 19

摘要

本工作研究了当内部永磁体(IPM)电机驱动器发生短路或不受控制的发电机模式故障时,中断相电流的方法。提出了一种容错硅开关,用晶闸管代替反向阻断逆变器开关中的反并联二极管。还提出了一种减少零件数的故障中断拓扑结构,该拓扑结构由插入Y形连接IPM电机定子绕组中心星形点的三角形连接晶闸管组成。讨论了所提出的减少零件数容错驱动器的控制,并给出了仿真结果来验证所提出的拓扑结构的操作。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Fault interrupting methods and topologies for interior PM machine drives
This work investigates methods to interrupt the phase currents induced when interior permanent magnet (IPM) machine drives suffer short-circuit or uncontrolled generator mode faults. A fault-tolerant silicon switch is proposed in which the antiparallel diode in a reverse-blocking inverter switch is replaced by a thyristor. A reduced-parts-count fault-interrupting topology is also proposed which consists of delta-connected thyristors inserted at the center star point of wye-connected IPM machine stator windings. Control of the proposed reduced-parts-count fault-tolerant drive is discussed and simulation results are presented to verify operation of the proposed topology.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Table of contents IEEE Power Electronics Letters blank page IEEE Power Electronics Society Information Order form for reprints 2005 Index
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1