带两级级联输出滤波器的单相电压源UPS逆变器的稳定性分析与仿真

J. Faiz, G. Shahgholian, M. Ehsan
{"title":"带两级级联输出滤波器的单相电压源UPS逆变器的稳定性分析与仿真","authors":"J. Faiz, G. Shahgholian, M. Ehsan","doi":"10.1002/ETEP.160","DOIUrl":null,"url":null,"abstract":"The primary role of an uninterruptible power supply (UPS) systems is to produce sinusoidal output voltage with minimum total harmonic distortion (THD) and fast dynamic response. This paper investigates the performance of two-stage cascade output filter for single-phase voltage source UPS inverter and it is compared with an LC output filter. The simulation result shows harmonic reduction of output voltage of the inverter due to using multiple-filter. Both THD of the low output voltage and good voltage utilization can be achieved by the proposed filter scheme. The THD of the output voltage in various load condition are all less than 4%. A good agreement between the simulation and experimental results is achieved. Copyright © 2007 John Wiley & Sons, Ltd.","PeriodicalId":50474,"journal":{"name":"European Transactions on Electrical Power","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2008-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/ETEP.160","citationCount":"26","resultStr":"{\"title\":\"Stability analysis and simulation of a single‐phase voltage source UPS inverter with two‐stage cascade output filter\",\"authors\":\"J. Faiz, G. Shahgholian, M. Ehsan\",\"doi\":\"10.1002/ETEP.160\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The primary role of an uninterruptible power supply (UPS) systems is to produce sinusoidal output voltage with minimum total harmonic distortion (THD) and fast dynamic response. This paper investigates the performance of two-stage cascade output filter for single-phase voltage source UPS inverter and it is compared with an LC output filter. The simulation result shows harmonic reduction of output voltage of the inverter due to using multiple-filter. Both THD of the low output voltage and good voltage utilization can be achieved by the proposed filter scheme. The THD of the output voltage in various load condition are all less than 4%. A good agreement between the simulation and experimental results is achieved. Copyright © 2007 John Wiley & Sons, Ltd.\",\"PeriodicalId\":50474,\"journal\":{\"name\":\"European Transactions on Electrical Power\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1002/ETEP.160\",\"citationCount\":\"26\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Transactions on Electrical Power\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1002/ETEP.160\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Transactions on Electrical Power","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/ETEP.160","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 26

摘要

不间断电源系统的主要作用是产生具有最小总谐波失真(THD)和快速动态响应的正弦输出电压。本文研究了单相电压源型UPS逆变器的两级级输出滤波器的性能,并与LC输出滤波器进行了比较。仿真结果表明,采用多重滤波器后,逆变器输出电压谐波降低。该滤波方案既能实现低输出电压的THD,又能实现良好的电压利用率。各种负载条件下输出电压的THD均小于4%。仿真结果与实验结果吻合较好。版权所有©2007 John Wiley & Sons, Ltd
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Stability analysis and simulation of a single‐phase voltage source UPS inverter with two‐stage cascade output filter
The primary role of an uninterruptible power supply (UPS) systems is to produce sinusoidal output voltage with minimum total harmonic distortion (THD) and fast dynamic response. This paper investigates the performance of two-stage cascade output filter for single-phase voltage source UPS inverter and it is compared with an LC output filter. The simulation result shows harmonic reduction of output voltage of the inverter due to using multiple-filter. Both THD of the low output voltage and good voltage utilization can be achieved by the proposed filter scheme. The THD of the output voltage in various load condition are all less than 4%. A good agreement between the simulation and experimental results is achieved. Copyright © 2007 John Wiley & Sons, Ltd.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
European Transactions on Electrical Power
European Transactions on Electrical Power 工程技术-工程:电子与电气
自引率
0.00%
发文量
0
审稿时长
5.4 months
期刊最新文献
A fault location method based on genetic algorithm for high‐voltage direct current transmission line Generation companies' adaptive bidding strategies using finite-state automata in a single-sided electricity market Modelling and evaluation of the lightning arc between a power line and a nearby tree Inductance profile calculation of step winding structure in tubular linear reluctance motor using three-dimensional finite element method Study on microstructure and electrical properties of oil‐impregnated paper insulation after exposure to partial discharge
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1