高压直流输电成束导线电晕起始电压的数值计算

Zhong‐Xin Li, Guang-Fan Li, Jian-Bin Fan, Yu Yin
{"title":"高压直流输电成束导线电晕起始电压的数值计算","authors":"Zhong‐Xin Li, Guang-Fan Li, Jian-Bin Fan, Yu Yin","doi":"10.1002/ETEP.406","DOIUrl":null,"url":null,"abstract":"The corona onset voltage (COV) for bare overhead bundle conductors for transmission lines has been investigated using numerical calculations and the gas discharge theory. First, an accurate numerical method, the charge simulation method, was used to calculate the electric field distribution in the vicinity of bare sub-conductors in bundles. Then the electric field values and a criterion from the gas discharge theory were used to evaluate the onset voltage for negative coronas on the bare sub-conductors. The COVs obtained are in good agreement with literature data for laboratory models and full-scale test lines. Some numerical results for the COV for six-bundle conductors are also discussed. Copyright © 2010 John Wiley & Sons, Ltd.","PeriodicalId":50474,"journal":{"name":"European Transactions on Electrical Power","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2011-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/ETEP.406","citationCount":"6","resultStr":"{\"title\":\"Numerical calculation of the corona onset voltage for bundle conductors for HVDC transmission line\",\"authors\":\"Zhong‐Xin Li, Guang-Fan Li, Jian-Bin Fan, Yu Yin\",\"doi\":\"10.1002/ETEP.406\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The corona onset voltage (COV) for bare overhead bundle conductors for transmission lines has been investigated using numerical calculations and the gas discharge theory. First, an accurate numerical method, the charge simulation method, was used to calculate the electric field distribution in the vicinity of bare sub-conductors in bundles. Then the electric field values and a criterion from the gas discharge theory were used to evaluate the onset voltage for negative coronas on the bare sub-conductors. The COVs obtained are in good agreement with literature data for laboratory models and full-scale test lines. Some numerical results for the COV for six-bundle conductors are also discussed. Copyright © 2010 John Wiley & Sons, Ltd.\",\"PeriodicalId\":50474,\"journal\":{\"name\":\"European Transactions on Electrical Power\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1002/ETEP.406\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Transactions on Electrical Power\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1002/ETEP.406\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Transactions on Electrical Power","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/ETEP.406","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

采用数值计算和气体放电理论对输电线路裸架空束导线的电晕起电压进行了研究。首先,采用电荷模拟的精确数值方法,计算了束内裸子导体附近的电场分布。然后用电场值和气体放电理论的判据计算了裸露子导体上负电晕的起始电压。获得的冠状病毒与实验室模型和全尺寸测试线的文献数据吻合良好。讨论了六束导体COV的一些数值结果。版权所有©2010 John Wiley & Sons, Ltd
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Numerical calculation of the corona onset voltage for bundle conductors for HVDC transmission line
The corona onset voltage (COV) for bare overhead bundle conductors for transmission lines has been investigated using numerical calculations and the gas discharge theory. First, an accurate numerical method, the charge simulation method, was used to calculate the electric field distribution in the vicinity of bare sub-conductors in bundles. Then the electric field values and a criterion from the gas discharge theory were used to evaluate the onset voltage for negative coronas on the bare sub-conductors. The COVs obtained are in good agreement with literature data for laboratory models and full-scale test lines. Some numerical results for the COV for six-bundle conductors are also discussed. Copyright © 2010 John Wiley & Sons, Ltd.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
European Transactions on Electrical Power
European Transactions on Electrical Power 工程技术-工程:电子与电气
自引率
0.00%
发文量
0
审稿时长
5.4 months
期刊最新文献
A fault location method based on genetic algorithm for high‐voltage direct current transmission line Generation companies' adaptive bidding strategies using finite-state automata in a single-sided electricity market Modelling and evaluation of the lightning arc between a power line and a nearby tree Inductance profile calculation of step winding structure in tubular linear reluctance motor using three-dimensional finite element method Study on microstructure and electrical properties of oil‐impregnated paper insulation after exposure to partial discharge
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1