大块Bi‐2212 MCP故障限流器材料的热性能测量

S. Schwenterly, D. Hazelton, H. Walter, F. Breuer
{"title":"大块Bi‐2212 MCP故障限流器材料的热性能测量","authors":"S. Schwenterly, D. Hazelton, H. Walter, F. Breuer","doi":"10.1063/1.2192425","DOIUrl":null,"url":null,"abstract":"In support of a collaboration between SuperPower, Inc., Nexans SuperConductors GmbH, American Electric Power Company, Inc., and EPRI to develop an HTS matrix fault current limiter, Oak Ridge National Laboratory is carrying out thermal property studies on samples of the bulk HTS elements that will be used in the device. The HTS samples are 2.5‐cm‐diam, 1.6‐mm‐wall tubes of Bi‐2212 MCP, a special melt‐cast 2212 material provided by Nexans. Since these tubes will have to dissipate considerable heat during a high‐current fault, accurate measurements of their thermal properties are required for design and engineering analysis. Results will be reported for heat capacity tests over a range from 80 K to 300 K.","PeriodicalId":80359,"journal":{"name":"Advances in cryogenic engineering","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2006-04-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1063/1.2192425","citationCount":"0","resultStr":"{\"title\":\"Thermal Property Measurements on Bulk Bi‐2212 MCP Fault Current Limiter Materials\",\"authors\":\"S. Schwenterly, D. Hazelton, H. Walter, F. Breuer\",\"doi\":\"10.1063/1.2192425\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In support of a collaboration between SuperPower, Inc., Nexans SuperConductors GmbH, American Electric Power Company, Inc., and EPRI to develop an HTS matrix fault current limiter, Oak Ridge National Laboratory is carrying out thermal property studies on samples of the bulk HTS elements that will be used in the device. The HTS samples are 2.5‐cm‐diam, 1.6‐mm‐wall tubes of Bi‐2212 MCP, a special melt‐cast 2212 material provided by Nexans. Since these tubes will have to dissipate considerable heat during a high‐current fault, accurate measurements of their thermal properties are required for design and engineering analysis. Results will be reported for heat capacity tests over a range from 80 K to 300 K.\",\"PeriodicalId\":80359,\"journal\":{\"name\":\"Advances in cryogenic engineering\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-04-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1063/1.2192425\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Advances in cryogenic engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1063/1.2192425\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in cryogenic engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1063/1.2192425","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

为了支持SuperPower公司、Nexans超导体公司、美国电力公司和EPRI之间的合作,开发一种高温超导矩阵故障限流器,橡树岭国家实验室正在对将用于该设备的大量高温超导元件的样品进行热性能研究。HTS样品是直径2.5 cm,壁1.6 mm的Bi - 2212 MCP管,这是一种由Nexans提供的特殊熔铸2212材料。由于这些管在大电流故障期间必须散发相当大的热量,因此需要对其热性能进行精确测量,以进行设计和工程分析。热容测试的结果将在80k到300k的范围内报告。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Thermal Property Measurements on Bulk Bi‐2212 MCP Fault Current Limiter Materials
In support of a collaboration between SuperPower, Inc., Nexans SuperConductors GmbH, American Electric Power Company, Inc., and EPRI to develop an HTS matrix fault current limiter, Oak Ridge National Laboratory is carrying out thermal property studies on samples of the bulk HTS elements that will be used in the device. The HTS samples are 2.5‐cm‐diam, 1.6‐mm‐wall tubes of Bi‐2212 MCP, a special melt‐cast 2212 material provided by Nexans. Since these tubes will have to dissipate considerable heat during a high‐current fault, accurate measurements of their thermal properties are required for design and engineering analysis. Results will be reported for heat capacity tests over a range from 80 K to 300 K.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The Aspect-Ratio Effect of He II Channels on the Heat Transport Characteristics Effect of Flow-Pressure Phase on Performance of Regenerators in the Range of 4 K to 20 K Cryocoolers for aircraft superconducting generators and motors Steady-State heat transfer through micro-channels in pressurized He II Forced convection heat transfer of subcooled liquid hydrogen in horizontal tubes
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1