{"title":"帕多瓦(意大利)医院的质量改进体系。","authors":"C. Favaretti, A. Mariotto","doi":"10.1093/OXFORDJOURNALS.INTQHC.A036715","DOIUrl":null,"url":null,"abstract":"A quality improvement system has been established in 1989 in the hospital network of Padua and its organization is described. Three selected experiences are reported. (1) Appropriateness of the use of human albumin. After the assessment of the clinical policy, new guidelines were experimentally introduced and an evaluation after 3 months has shown a decrease of the total number of prescriptions (25%) and of inappropriate indications (9% vs 40.1%). (2) Urinary Tract Infections (UTI) and indwelling catheterization. The study showed 49% of conditions related to UTI and some corrigible inadequacies in the process of care: 37.2% of indications were probably not justified; 40% of patients who did not undergo urineculture had indications and 13% who underwent urineculture had no indications to the test. Guidelines for appropriate indications and a continuing education programme have been introduced. (3) Falls by hospitalized patients. The patient fall rate was 0.3/1000. As the reporting system showed inaccuracies (for example, the severity of injury was not collected in 34% of cases), a new notification form was introduced in 1991.","PeriodicalId":77341,"journal":{"name":"Quality assurance in health care : the official journal of the International Society for Quality Assurance in Health Care","volume":"4 2 1","pages":"97-104"},"PeriodicalIF":0.0000,"publicationDate":"1992-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1093/OXFORDJOURNALS.INTQHC.A036715","citationCount":"6","resultStr":"{\"title\":\"The quality improvement system in the hospitals of Padua (Italy).\",\"authors\":\"C. Favaretti, A. Mariotto\",\"doi\":\"10.1093/OXFORDJOURNALS.INTQHC.A036715\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A quality improvement system has been established in 1989 in the hospital network of Padua and its organization is described. Three selected experiences are reported. (1) Appropriateness of the use of human albumin. After the assessment of the clinical policy, new guidelines were experimentally introduced and an evaluation after 3 months has shown a decrease of the total number of prescriptions (25%) and of inappropriate indications (9% vs 40.1%). (2) Urinary Tract Infections (UTI) and indwelling catheterization. The study showed 49% of conditions related to UTI and some corrigible inadequacies in the process of care: 37.2% of indications were probably not justified; 40% of patients who did not undergo urineculture had indications and 13% who underwent urineculture had no indications to the test. Guidelines for appropriate indications and a continuing education programme have been introduced. (3) Falls by hospitalized patients. The patient fall rate was 0.3/1000. As the reporting system showed inaccuracies (for example, the severity of injury was not collected in 34% of cases), a new notification form was introduced in 1991.\",\"PeriodicalId\":77341,\"journal\":{\"name\":\"Quality assurance in health care : the official journal of the International Society for Quality Assurance in Health Care\",\"volume\":\"4 2 1\",\"pages\":\"97-104\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1992-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1093/OXFORDJOURNALS.INTQHC.A036715\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Quality assurance in health care : the official journal of the International Society for Quality Assurance in Health Care\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1093/OXFORDJOURNALS.INTQHC.A036715\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Quality assurance in health care : the official journal of the International Society for Quality Assurance in Health Care","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/OXFORDJOURNALS.INTQHC.A036715","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

1989年在帕多瓦医院网络中建立了质量改进体系,并对其组织进行了描述。报告了三个选定的经验。(1)人白蛋白使用的适宜性。在对临床政策进行评估后,实验性地引入了新的指南,3个月后的评估显示,处方总数(25%)和不适当适应症(9%对40.1%)减少了。(2)尿路感染(UTI)和留置导尿。研究显示,49%的情况与尿路感染有关,在护理过程中存在一些可纠正的不足:37.2%的指征可能不合理;未接受尿培养的患者中有40%有适应证,而接受尿培养的患者中有13%没有适应证。引入了适当适应症的指导方针和继续教育方案。(3)住院患者跌倒。患者跌倒率为0.3/1000。由于报告系统显示不准确(例如,在34%的病例中没有收集伤害的严重程度),1991年采用了一种新的通知表格。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The quality improvement system in the hospitals of Padua (Italy).
A quality improvement system has been established in 1989 in the hospital network of Padua and its organization is described. Three selected experiences are reported. (1) Appropriateness of the use of human albumin. After the assessment of the clinical policy, new guidelines were experimentally introduced and an evaluation after 3 months has shown a decrease of the total number of prescriptions (25%) and of inappropriate indications (9% vs 40.1%). (2) Urinary Tract Infections (UTI) and indwelling catheterization. The study showed 49% of conditions related to UTI and some corrigible inadequacies in the process of care: 37.2% of indications were probably not justified; 40% of patients who did not undergo urineculture had indications and 13% who underwent urineculture had no indications to the test. Guidelines for appropriate indications and a continuing education programme have been introduced. (3) Falls by hospitalized patients. The patient fall rate was 0.3/1000. As the reporting system showed inaccuracies (for example, the severity of injury was not collected in 34% of cases), a new notification form was introduced in 1991.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The current status of autopsies in medical care in the USA. Decrease in the frequency of autopsies in Denmark after the introduction of a new autopsy act. Decreasing autopsy rate in Sweden reflects changing attitudes among clinicians. The meta-autopsy: changing techniques and attitudes towards the autopsy. The reliability of autopsy diagnostics: inter-observer variation between pathologists, a preliminary report.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1