一种计算效率高的拍对拍信号在线频谱分析算法

P. Castiglioni, M. Rienzo, H. Yosh
{"title":"一种计算效率高的拍对拍信号在线频谱分析算法","authors":"P. Castiglioni, M. Rienzo, H. Yosh","doi":"10.1109/CIC.2002.1166798","DOIUrl":null,"url":null,"abstract":"A new algorithm is proposed for the online Fourier analysis of unevenly sampled data. The method is based on the theoretical evaluation of the Fourier Transform of a function linearly interpolating the data, and does not require actual interpolation and re-sampling. The method is particularly suitable for the running evaluation of power spectra. In fact, when a new sample is available, the spectrum can be updated simply by performing calculations on the last sample, without the need to calculate the Fourier Transform again over the whole data record. Applications with simulated and real data show the capability of the algorithm to efficiently estimate the Fourier transform of unevenly sampled cardiovascular data, beat after beat.","PeriodicalId":80984,"journal":{"name":"Computers in cardiology","volume":"1 1","pages":"417-420"},"PeriodicalIF":0.0000,"publicationDate":"2002-09-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1109/CIC.2002.1166798","citationCount":"5","resultStr":"{\"title\":\"A computationally efficient algorithm for online spectral analysis of beat-to-beat signals\",\"authors\":\"P. Castiglioni, M. Rienzo, H. Yosh\",\"doi\":\"10.1109/CIC.2002.1166798\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A new algorithm is proposed for the online Fourier analysis of unevenly sampled data. The method is based on the theoretical evaluation of the Fourier Transform of a function linearly interpolating the data, and does not require actual interpolation and re-sampling. The method is particularly suitable for the running evaluation of power spectra. In fact, when a new sample is available, the spectrum can be updated simply by performing calculations on the last sample, without the need to calculate the Fourier Transform again over the whole data record. Applications with simulated and real data show the capability of the algorithm to efficiently estimate the Fourier transform of unevenly sampled cardiovascular data, beat after beat.\",\"PeriodicalId\":80984,\"journal\":{\"name\":\"Computers in cardiology\",\"volume\":\"1 1\",\"pages\":\"417-420\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2002-09-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1109/CIC.2002.1166798\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Computers in cardiology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CIC.2002.1166798\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Computers in cardiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CIC.2002.1166798","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

提出了一种用于非均匀采样数据在线傅里叶分析的新算法。该方法基于函数的傅里叶变换对数据进行线性插值的理论评价,不需要实际的插值和重采样。该方法特别适用于功率谱的运行评定。事实上,当一个新的样本可用时,频谱可以简单地通过对最后一个样本进行计算来更新,而不需要对整个数据记录再次计算傅里叶变换。模拟和实际数据的应用表明,该算法能够有效地估计采样不均匀的心血管数据的傅里叶变换。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A computationally efficient algorithm for online spectral analysis of beat-to-beat signals
A new algorithm is proposed for the online Fourier analysis of unevenly sampled data. The method is based on the theoretical evaluation of the Fourier Transform of a function linearly interpolating the data, and does not require actual interpolation and re-sampling. The method is particularly suitable for the running evaluation of power spectra. In fact, when a new sample is available, the spectrum can be updated simply by performing calculations on the last sample, without the need to calculate the Fourier Transform again over the whole data record. Applications with simulated and real data show the capability of the algorithm to efficiently estimate the Fourier transform of unevenly sampled cardiovascular data, beat after beat.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Dynamically-Induced Spatial Dispersion of Repolarization and the Development of VF in an Animal Model of Sudden Death. An Anisotropic Fluid-Solid Model of the Mouse Heart. Dynamic Cardiovagal Response to Motion Sickness: A Point-Process Heart Rate Variability Study. The Effect of Signal Quality on Six Cardiac Output Estimators. Predicting Acute Hypotensive Episodes: The 10th Annual PhysioNet/Computers in Cardiology Challenge.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1